Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty

被引:120
|
作者
Hoenecke, Heinz R., Jr. [1 ]
Hermida, Juan C. [1 ]
Flores-Hernandez, Cesar [1 ]
D'Lima, Darryl D. [1 ]
机构
[1] Scripps Clin, Shiley Ctr Orthopaed Res & Educ, La Jolla, CA 92037 USA
关键词
Total shoulder arthroplasty; shoulder arthritis; 3-D reconstruction; scapular axis; glenoid version; TOMOGRAPHY; RETROVERSION;
D O I
10.1016/j.jse.2009.08.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background/Hypothesis: The arthritic glenoid is typically in retroversion and restoration to neutral version is recommended. While a method for measurement of glenoid version using axial computed tomography (CT) has been reported and has been widely accepted, its accuracy and reproducibility has not been established. Methods: In 33 patients scheduled for shoulder arthroplasty, glenoid version and maximum wear of the glenoid articular surface were measured with respect to the scapular body axis on 2-dimensional- (2D) CT slices as well as on 3-dimensional- (3D) reconstructed models of the same CT slices. Results: Clinical CT scans were axially aligned with the patient's torso but were almost never perpendicular to the scapular body. The average absolute error in version measured on the 2D-CT slice passing through the tip of the coracoid was 5.1 degrees (range, 0 - 16 degrees, P < .001). On high-resolution 3D-CT reconstructions, the location of maximum wear was most commonly posterior and was missed on the clinical 2D-CT slices in 52% of cases. Conclusion: Error in measuring version and depth of maximum wear can substantially affect the determination of the degree of correction necessary in arthritic glenoids. Accurately measuring glenoid version and locating the direction of maximum wear requires a full 3D-CT reconstruction and analysis. Level of Evidence: Level I; Diagnostic Study. (C) 2010 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 50 条
  • [1] Determining glenoid component version after total shoulder arthroplasty
    Mehta, Manish P.
    Vogel, Laura A.
    Shiu, Brian B.
    Dennis, Elizabeth R.
    Petkovic, Djuro
    Levine, William N.
    Jobin, Charles M.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (09) : 1588 - 1595
  • [2] The Y plane is a reliable CT-based reference for glenoid component positioning in shoulder arthroplasty
    Jean-Marc Glasson
    Floris van Rooij
    Luca Nover
    Mo Saffarini
    Jean Kany
    [J]. Journal of Experimental Orthopaedics, 9
  • [3] The Y plane is a reliable CT-based reference for glenoid component positioning in shoulder arthroplasty
    Glasson, Jean-Marc
    van Rooij, Floris
    Nover, Luca
    Saffarini, Mo
    Kany, Jean
    [J]. JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2022, 9 (01)
  • [4] The glenoid in total shoulder arthroplasty
    Schrumpf M.
    Maak T.
    Hammoud S.
    Craig E.V.
    [J]. Current Reviews in Musculoskeletal Medicine, 2011, 4 (4) : 191 - 199
  • [5] Accuracy and reliability of postoperative radiographic measurements of glenoid anatomy and relationships in patients with total shoulder arthroplasty
    Ho, Jason C.
    Youderian, Ari
    Davidson, Iyooh U.
    Bryan, Jason
    Iannotti, Joseph P.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (08) : 1068 - 1077
  • [6] Humeral and Glenoid Version in Reverse Total Shoulder Arthroplasty: A Systematic Review
    Berton, Alessandra
    Longo, Umile Giuseppe
    Gulotta, Lawrence V.
    De Salvatore, Sergio
    Piergentili, Ilaria
    Calabrese, Giovanni
    Roberti, Federica
    Warren, Russell F.
    Denaro, Vincenzo
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [7] Robotic total knee arthroplasty - The accuracy of CT-based component placement
    Decking, J
    Theis, C
    Achenbach, T
    Roth, E
    Nafe, B
    Eckardt, A
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (05): : 573 - 579
  • [8] Glenoid exposure in total shoulder arthroplasty
    Nove-Josserand, L.
    Clavert, P.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (01) : S129 - S135
  • [9] Glenoid replacement in total shoulder arthroplasty
    Keller, J
    Bak, S
    Bigliani, LU
    Levine, WN
    [J]. ORTHOPEDICS, 2006, 29 (03) : 221 - 226
  • [10] Glenoid exposure for total shoulder arthroplasty
    Katz, D
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (02): : 171 - 175