Robotic total knee arthroplasty - The accuracy of CT-based component placement

被引:59
|
作者
Decking, J [1 ]
Theis, C
Achenbach, T
Roth, E
Nafe, B
Eckardt, A
机构
[1] Univ Mainz, Dept Orthopaed Surg, D-6500 Mainz, Germany
[2] Univ Mainz, Dept Radiol, D-6500 Mainz, Germany
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 2004年 / 75卷 / 05期
关键词
D O I
10.1080/00016470410001448
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Accurate alignment of the components in total knee arthroplasty is important. By use of postoperative CT controls, we studied the ability of a robotic effector to accurately place and align total knee arthroplasty (TKA) components according to a purely CT-based preoperative plan. Patients and methods Robotic TKA was performed in 13 patients (6 men) with primary gonarthrosis. Locator screws were placed into femur and tibia under spinal anesthesia. A CT-scan including the femoral head, knee and ankle was performed. In the preoperative planning software, virtual components were positioned into the CT volume. In a second operation, the robot milled femur and tibia with a high-speed milling too] according to the preoperative plan. On the 10th day, CT controls were performed following the same protocol as preoperatively. Results The mean deviation of the postoperative from the preoperatively planned mechanical axis was 0.2degrees (95% CI: -0.1degrees to 0.5degrees). The accuracy of angular component placement in frontal, sagittal and transverse planes was within +/- 1.2degrees, and the accuracy of linear component placement in mediolateral, dorsoventral and caudocranial directions was within +/- 1.1 mm. Interpretation Robotic TKA allows placement of components with unparalleled accuracy, but further development is mandatory to integrate soft-tissue balancing into the procedure and make it faster, easier and cheaper.
引用
收藏
页码:573 / 579
页数:7
相关论文
共 50 条
  • [1] Implant placement accuracy in total knee arthroplasty: validation of a CT-based measurement technique
    Campanelli, Valentina
    Lozano, Rocio
    Akhlaghpour, Hosna
    Brar, Abheetinder S.
    Maislin, David
    Nedopil, Alexander J.
    Zuhars, Joel
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (02) : 475 - 484
  • [2] Improved Component Placement Accuracy with Robotic-Arm Assisted Total Knee Arthroplasty
    Mahoney, Ormonde
    Kinsey, Tracey
    Sodhi, Nipun
    Mont, Michael A.
    Chen, Antonia F.
    Orozco, Fabio
    Hozack, William
    [J]. JOURNAL OF KNEE SURGERY, 2022, 35 (03) : 337 - 344
  • [3] Accuracy of 2D CT-Based Measurements of Rotational Alignment of the Femoral Component for Total Knee Arthroplasty
    Park, Jun Young
    Kwon, Hyuck Min
    Cho, Byung Woo
    Lee, Woo-Suk
    Yang, Ick Hwan
    Park, Kwan Kyu
    [J]. YONSEI MEDICAL JOURNAL, 2021, 62 (05) : 439 - 445
  • [4] Accuracy of Component Placement in Robotic-Assisted Total Hip Arthroplasty
    Redmond, John M.
    Gupta, Asheesh
    Hammarstedt, Jon E.
    Petrakos, Alexandrara
    Stake, Christine E.
    Domb, Benjamin G.
    [J]. ORTHOPEDICS, 2016, 39 (03) : 193 - 199
  • [5] The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty
    K. Y. Chiu
    W. P. Yau
    T. P. Ng
    W. M. Tang
    [J]. International Orthopaedics, 2008, 32 : 467 - 471
  • [6] The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty
    Chiu, K. Y.
    Yau, W. P.
    Ng, T. P.
    Tang, W. M.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2008, 32 (04) : 467 - 471
  • [7] Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty
    Hoenecke, Heinz R., Jr.
    Hermida, Juan C.
    Flores-Hernandez, Cesar
    D'Lima, Darryl D.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (02) : 166 - 171
  • [8] Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system
    Nakahara, Ichiro
    Kyo, Takayuki
    Kuroda, Yasuo
    Miki, Hidenobu
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (03) : 340 - 347
  • [9] Comparison of Alignment Accuracy and Clinical Outcomes between a CT-Based, Saw Cutting Robotic System and a CT-Free, Jig-guided Robotic System for Total Knee Arthroplasty
    Zhou, Ge
    Wang, Xinguang
    Geng, Xiao
    Li, Zijian
    Tian, Hua
    [J]. ORTHOPAEDIC SURGERY, 2024, 16 (05) : 1168 - 1174
  • [10] Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system
    Ichiro Nakahara
    Takayuki Kyo
    Yasuo Kuroda
    Hidenobu Miki
    [J]. Journal of Artificial Organs, 2018, 21 : 340 - 347