Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry

被引:70
|
作者
Belov, Arseniy M. [1 ]
Viner, Rosa [2 ]
Santos, Marcia R. [3 ]
Horn, David M. [2 ]
Bern, Marshall [4 ]
Karger, Barry L. [1 ]
Ivanov, Alexander R. [1 ]
机构
[1] Northeastern Univ, Barnett Inst Chem & Biol Anal, Boston, MA 02115 USA
[2] Thermo Fisher Sci, San Jose, CA 95134 USA
[3] SCIEX Ltd, Brea, CA 92821 USA
[4] Prot Metr, San Carlos, CA 94070 USA
关键词
Capillary zone electrophoresis; Sheathless CZE-MS; Native mass spectrometry; Top-down mass spectrometry; Ultra-low flow separations; Protein complexes; Ribosome; Specialized ribosomes; Proteoform; Aggregation of biopharmaceutical proteins; FIELD-FLOW FRACTIONATION; ESCHERICHIA-COLI; RIBOSOMAL-PROTEINS; YEAST ENOLASE; GAS-PHASE; LIQUID-CHROMATOGRAPHY; MONOCLONAL-ANTIBODY; STRUCTURAL BASIS; SEPARATION; MS;
D O I
10.1007/s13361-017-1781-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Native mass spectrometry (MS) is a rapidly advancing field in the analysis of proteins, protein complexes, and macromolecular species of various types. The majority of native MS experiments reported to-date has been conducted using direct infusion of purified analytes into a mass spectrometer. In this study, capillary zone electrophoresis (CZE) was coupled online to Orbitrap mass spectrometers using a commercial sheathless interface to enable high-performance separation, identification, and structural characterization of limited amounts of purified proteins and protein complexes, the latter with preserved non-covalent associations under native conditions. The performance of both bare-fused silica and polyacrylamide-coated capillaries was assessed using mixtures of protein standards known to form non-covalent protein-protein and protein-ligand complexes. High-efficiency separation of native complexes is demonstrated using both capillary types, while the polyacrylamide neutral-coated capillary showed better reproducibility and higher efficiency for more complex samples. The platform was then evaluated for the determination of monoclonal antibody aggregation and for analysis of proteomes of limited complexity using a ribosomal isolate from E. coli. Native CZE-MS, using accurate single stage and tandem-MS measurements, enabled identification of proteoforms and non-covalent complexes at femtomole levels. This study demonstrates that native CZE-MS can serve as an orthogonal and complementary technique to conventional native MS methodologies with the advantages of low sample consumption, minimal sample processing and losses, and high throughput and sensitivity. This study presents a novel platform for analysis of ribosomes and other macromolecular complexes and organelles, with the potential for discovery of novel structural features defining cellular phenotypes (e.g., specialized ribosomes).
引用
收藏
页码:2614 / 2634
页数:21
相关论文
共 50 条
  • [41] Protein and peptide identification by capillary zone electrophoresis-tandem mass spectrometry
    Liu, T
    Zeng, R
    Shao, XX
    Xia, QC
    ACTA BIOCHIMICA ET BIOPHYSICA SINICA, 1999, 31 (04): : 425 - 432
  • [42] Characterization of protein glycoforms by capillary-zone electrophoresis nanoelectrospray mass spectrometry
    Bateman, KP
    White, RL
    Yaguchi, M
    Thibault, P
    JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) : 327 - 344
  • [43] On-column sample enrichment for capillary electrophoresis sheathless electrospray ionization mass spectrometry: Evaluation for peptide analysis and protein identification
    Janini, GM
    Zhou, M
    Yu, LR
    Blonder, J
    Gignac, M
    Conrads, TP
    Issaq, HJ
    Veenstra, TD
    ANALYTICAL CHEMISTRY, 2003, 75 (21) : 5984 - 5993
  • [44] In-depth analysis of monoclonal antibodies using microfluidic capillary electrophoresis and native mass spectrometry
    Carillo, Sara
    Jakes, Craig
    Bones, Jonathan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 185
  • [45] Sheathless reverse-polarity capillary electrophoresis-electrospray-mass spectrometry for analysis of underivatized glycoconjugates
    Bindila, L
    Peter-Katalinic, J
    Zamfir, A
    ELECTROPHORESIS, 2005, 26 (7-8) : 1488 - 1499
  • [46] Capillary electrophoresis mass spectrometry with sheathless electrospray ionization for high sensitivity analysis of underivatized amino acids
    Jeong, Ji-Seon
    Kim, Sook-Kyung
    Park, Sang-Ryoul
    ELECTROPHORESIS, 2012, 33 (14) : 2112 - 2121
  • [47] Two-dimensional liquid chromatography-capillary zone electrophoresis-sheathless electrospray ionization-mass spectrometry: Evaluation for peptide analysis and protein identification
    Janini, GM
    Chan, KC
    Conrads, TP
    Issaq, HJ
    Veenstra, TD
    ELECTROPHORESIS, 2004, 25 (13) : 1973 - 1980
  • [48] On-line enhancement technique for the analysis of nucleotides using capillary zone electrophoresis/mass spectrometry
    Feng, Yong-Lai
    Zhu, Jiping
    ANALYTICAL CHEMISTRY, 2006, 78 (18) : 6608 - 6613
  • [49] Low-Flow Sheathless Capillary Electrophoresis-Mass Spectrometry for Sensitive Glycoform Profiling of Intact Pharmaceutical Proteins
    Haselberg, Rob
    de Jong, Gerhardus J.
    Somsen, Govert W.
    ANALYTICAL CHEMISTRY, 2013, 85 (04) : 2289 - 2296
  • [50] Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins
    Haselberg, Rob
    Ratnayake, Chitra K.
    de Jong, Gerhardus J.
    Somsen, Govert W.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (48) : 7605 - 7611