Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins

被引:84
|
作者
Haselberg, Rob [1 ]
Ratnayake, Chitra K. [2 ]
de Jong, Gerhardus J. [1 ]
Somsen, Govert W. [1 ]
机构
[1] Univ Utrecht, Dept Biomed Anal, NL-3508 TB Utrecht, Netherlands
[2] Beckman Coulter Inc, Brea, CA 92822 USA
关键词
Capillary electrophoresis; Electrospray ionization; Intact proteins; Mass spectrometry; Sheathless interfacing; Sheath liquid interfacing; TIME-OF-FLIGHT; ZONE-ELECTROPHORESIS; CE-MS; INTERFACE; COMPLEXES; JUNCTION; SEPARATION; PEPTIDES; EMITTERS; DESIGN;
D O I
10.1016/j.chroma.2010.10.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of a prototype porous tip sprayer for sheathless capillary electrophoresis-mass spectrometry (CE-MS) of intact proteins was studied Capillaries with a porous tip were inserted in a stainless steel needle filled with static conductive liquid and installed in a conventional electrospray ionization (ESI) source Using a BCE of 100 mM acetic acid (pH 3 1) and a positively charged capillary coating a highly reproducible and efficient separation of four model proteins (insulin carbonic anhydrase II ribonuclease A and lysozyme) was obtained The protein mass spectra were of good quality allowing reliable mass determination of the proteins and some of their impurities Sheath-liquid CE-MS using the same porous tip capillary and an isopropanol-water-acetic acid sheath liquid showed slightly lower to similar analyte responses However as noise levels increased with sheath-liquid CE-MS detection limits were improved by a factor 6 5-20 with sheathless CE-MS The analyte response in sheathless CE-MS could be enhanced using a nanoESI source and adding 5% isopropanol to the BCE leading to improved detection limits by 50-fold to 140-fold as compared to sheath liquid interfacing using the same capillary - equivalent to sub-nM detection limits for three out of four proteins Clearly the sheathless porous tip sprayer provides high sensitivity CE-MS of intact proteins (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:7605 / 7611
页数:7
相关论文
共 50 条
  • [1] Study of the electrical connection mechanism of sheathless interface for capillary electrophoresis-electrospray ionization-mass spectrometry
    Tie, Cai
    Zhang, De-Wen
    Chen, Hong-Xu
    Song, Sen-Lin
    Zhang, Xin-Xiang
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (11): : 1429 - 1434
  • [2] Microchip capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins using uncoated Ormocomp microchips
    Sikanen, Tiina
    Aura, Susanna
    Franssila, Sami
    Kotiaho, Tapio
    Kostiainen, Risto
    ANALYTICA CHIMICA ACTA, 2012, 711 : 69 - 76
  • [3] Feasibility of nonvolatile buffers in capillary electrophoresis-electrospray ionization-mass spectrometry of proteins
    Eriksson, JHC
    Mol, R
    Somsen, GW
    Hinrichs, WLJ
    Frijlink, HW
    de Jong, GJ
    ELECTROPHORESIS, 2004, 25 (01) : 43 - 49
  • [4] A beveled tip sheath liquid interface for capillary electrophoresis-electrospray ionization-mass spectrometry
    Tseng, MC
    Chen, YR
    Her, GR
    ELECTROPHORESIS, 2004, 25 (13) : 2084 - 2089
  • [5] Comparison of sheathless and sheath-flow electrospray interfaces for the capillary electrophoresis-electrospray ionization-mass spectrometry analysis of peptides
    Sanz-Nebot, V
    Balaguer, E
    Benavente, F
    Barbosa, J
    ELECTROPHORESIS, 2005, 26 (7-8) : 1457 - 1465
  • [6] A polyamine coating for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry of proteins and peptides
    Ullsten, S
    Zuberovic, A
    Wetterhall, M
    Hardenborg, E
    Markides, KE
    Bergquist, J
    ELECTROPHORESIS, 2004, 25 (13) : 2090 - 2099
  • [7] In-spray supercharging of intact proteins by capillary electrophoresis-electrospray ionization-mass spectrometry using sheath liquid interface
    Bonvin, Gregoire
    Rudaz, Serge
    Schappler, Julie
    ANALYTICA CHIMICA ACTA, 2014, 813 : 97 - 105
  • [8] Glycoprotein characterization combining intact protein and glycan analysis by capillary electrophoresis-electrospray ionization-mass spectrometry
    Balaguer, Elvira
    Neusuess, Christian
    ANALYTICAL CHEMISTRY, 2006, 78 (15) : 5384 - 5393
  • [9] Snake venom characteristic peptides: novel fingerprints for species identification by sheathless capillary electrophoresis-electrospray ionization-mass spectrometry
    Liu, Ying
    Zhang, Xiao-Hui
    Yu, Yue
    Chen, Hong-Xu
    Zhou, Ying-Lin
    Zhang, Xin-Xiang
    ANALYST, 2020, 145 (14) : 5027 - 5031
  • [10] Determination of yessotoxins and pectenotoxins in shellfish by capillary electrophoresis-electrospray ionization-mass spectrometry
    de la Iglesia, P.
    Gago-Martinez, A.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (02): : 221 - 228