Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry

被引:70
|
作者
Belov, Arseniy M. [1 ]
Viner, Rosa [2 ]
Santos, Marcia R. [3 ]
Horn, David M. [2 ]
Bern, Marshall [4 ]
Karger, Barry L. [1 ]
Ivanov, Alexander R. [1 ]
机构
[1] Northeastern Univ, Barnett Inst Chem & Biol Anal, Boston, MA 02115 USA
[2] Thermo Fisher Sci, San Jose, CA 95134 USA
[3] SCIEX Ltd, Brea, CA 92821 USA
[4] Prot Metr, San Carlos, CA 94070 USA
关键词
Capillary zone electrophoresis; Sheathless CZE-MS; Native mass spectrometry; Top-down mass spectrometry; Ultra-low flow separations; Protein complexes; Ribosome; Specialized ribosomes; Proteoform; Aggregation of biopharmaceutical proteins; FIELD-FLOW FRACTIONATION; ESCHERICHIA-COLI; RIBOSOMAL-PROTEINS; YEAST ENOLASE; GAS-PHASE; LIQUID-CHROMATOGRAPHY; MONOCLONAL-ANTIBODY; STRUCTURAL BASIS; SEPARATION; MS;
D O I
10.1007/s13361-017-1781-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Native mass spectrometry (MS) is a rapidly advancing field in the analysis of proteins, protein complexes, and macromolecular species of various types. The majority of native MS experiments reported to-date has been conducted using direct infusion of purified analytes into a mass spectrometer. In this study, capillary zone electrophoresis (CZE) was coupled online to Orbitrap mass spectrometers using a commercial sheathless interface to enable high-performance separation, identification, and structural characterization of limited amounts of purified proteins and protein complexes, the latter with preserved non-covalent associations under native conditions. The performance of both bare-fused silica and polyacrylamide-coated capillaries was assessed using mixtures of protein standards known to form non-covalent protein-protein and protein-ligand complexes. High-efficiency separation of native complexes is demonstrated using both capillary types, while the polyacrylamide neutral-coated capillary showed better reproducibility and higher efficiency for more complex samples. The platform was then evaluated for the determination of monoclonal antibody aggregation and for analysis of proteomes of limited complexity using a ribosomal isolate from E. coli. Native CZE-MS, using accurate single stage and tandem-MS measurements, enabled identification of proteoforms and non-covalent complexes at femtomole levels. This study demonstrates that native CZE-MS can serve as an orthogonal and complementary technique to conventional native MS methodologies with the advantages of low sample consumption, minimal sample processing and losses, and high throughput and sensitivity. This study presents a novel platform for analysis of ribosomes and other macromolecular complexes and organelles, with the potential for discovery of novel structural features defining cellular phenotypes (e.g., specialized ribosomes).
引用
收藏
页码:2614 / 2634
页数:21
相关论文
共 50 条
  • [21] CAPILLARY ZONE ELECTROPHORESIS-MASS SPECTROMETRY
    OLIVARES, JA
    NGUYEN, NT
    SMITH, RD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 204 - ANYL
  • [22] Compact automated capillary electrophoresis instrument for coupling with mass spectrometry by using sheathless electrospray ionization
    Furter, Jasmine S.
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1656
  • [23] The Development of a Sheathless Interface for Capillary Electrophoresis Electrospray Ionization Mass Spectrometry Using a Cellulose Acetate Cast Capillary
    Ryan T. Johnson
    Nhan H. To
    John F. Stobaugh
    Craig E. Lunte
    Chromatographia, 2017, 80 : 1061 - 1067
  • [24] Coupling capillary electrophoresis.electrospray ionization mass spectrometry with sheathless interface for drug analysis
    Zhang Hanzhi
    Li Feng
    Kang Jingwu
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2023, 41 (02) : 160 - 167
  • [25] The Development of a Sheathless Interface for Capillary Electrophoresis Electrospray Ionization Mass Spectrometry Using a Cellulose Acetate Cast Capillary
    Johnson, Ryan T.
    To, Nhan H.
    Stobaugh, John F.
    Lunte, Craig E.
    CHROMATOGRAPHIA, 2017, 80 (07) : 1061 - 1067
  • [26] Resolving Volume-Restricted Metabolomics Using Sheathless Capillary Electrophoresis-Mass Spectrometry
    Ramautar, Rawi
    LC GC EUROPE, 2017, 30 (12) : 658 - 661
  • [27] Capillary electrophoresis-mass spectrometry for the analysis of intact proteins
    Haselberg, Rob
    de Jong, Gerhardus J.
    Somsen, Govert W.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) : 81 - 109
  • [28] ANALYSIS OF INOSITOL PHOSPHATES AND DERIVATIVES USING CAPILLARY ZONE ELECTROPHORESIS MASS-SPECTROMETRY
    BUSCHER, BAP
    VANDERHOEVEN, RAM
    TJADEN, UR
    ANDERSSON, E
    VANDERGREEF, J
    JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) : 235 - 243
  • [29] A sheathless nanoflow electrospray interface for on-line capillary electrophoresis mass spectrometry
    Janini, GM
    Conrads, TP
    Wilkens, KL
    Issaq, HJ
    Veenstra, TD
    ANALYTICAL CHEMISTRY, 2003, 75 (07) : 1615 - 1619
  • [30] Sheathless Capillary Electrophoresis-Mass Spectrometry for Metabolic Profiling of Biological Samples
    Zhang, Wei
    Gulersonmez, M. Can
    Hankemeier, Thomas
    Ramautar, Rawi
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (116):