Mixed Isotope Effects: Image Quality in Multimodality PET/SPECT Preclinical Imaging

被引:0
|
作者
Tainter, Kerrie H. [1 ]
Lokitz, Stephen J. [1 ]
Vascoe, Christopher [1 ]
Zhang, Joann [2 ]
Coco, Brent J. [2 ]
Iwata, Koji [2 ]
Wagenaar, Douglas J. [3 ]
Mathis, J. Michael [4 ,5 ]
机构
[1] Biomed Res Fdn NW Louisiana BRF, Shreveport, LA 71103 USA
[2] GE Healthcare, Preclin Imaging, Waukesha, WI USA
[3] GammaMedica Ideas, Northridge, CA USA
[4] Louisiana State Univ, Hlth Sci Ctr Shreveport, Dept Cellular Biol & Anat, Shreveport, LA 71105 USA
[5] Louisiana State Univ, Hlth Sci Ctr Shreveport, Gene Therapy Program, Shreveport, LA 71105 USA
关键词
D O I
10.1109/NSSMIC.2009.5401856
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The recent availability of pre-clinical PET/SPECT/CT tri-modality systems provides an opportunity to image animals injected with mixed modality (PET/SPECT) isotopes. However, before these procedures can be truly useful, some understanding of the effect of different modality radiotracers on image quality and the resulting noise characteristics must be investigated. Our goal in this study was to characterize effects on image resolution that might arise in one modality because of the presence of another (different modality) isotope. A phantom, consisting of a set of side-by-side micro-capillary tubes, were imaged on a trimodality (SPECT/PET/CT) pre-clinical scanner. Each tube was filled with a SPECT isotope and imaged while varying acquisition time, amount of activity, and distance between line sources. Images were evaluated to determine the visualization threshold at which objects became apparent in cross-sectional and MIP images (both that the objects were line sources and that the lines were two separate objects). These experiments were repeated in the presence of a PET isotope. After re-evaluating resolution, the signal to noise characteristics of the image as a whole were assessed and related to amounts of each isotope as well as total activity in the field of view. PET acquisition in the presence of SPECT isotopes was investigated using a contrast phantom with spheres filled with PET, SPECT, and mixed isotopes in backgrounds of mixed SPECT and PET isotopes. The noise properties of the background and spheres were measured as well as the visibility of the spheres. Finally, SPEC, PET, and CT images were acquired of a mouse after injection of both a PET and SPECT isotope. Acquisition of SPECT and PET images in the presence of different modality tracers (with careful considerations of the activity and acquisition parameters) seems feasible.
引用
收藏
页码:3675 / +
页数:2
相关论文
共 50 条
  • [1] Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging
    Keiichi Magota
    Naoki Kubo
    Yuji Kuge
    Ken-ichi Nishijima
    Songji Zhao
    Nagara Tamaki
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 742 - 752
  • [2] Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging
    Magota, Keiichi
    Kubo, Naoki
    Kuge, Yuji
    Nishijima, Ken-ichi
    Zhao, Songji
    Tamaki, Nagara
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (04) : 742 - 752
  • [3] Multimodality Imaging: Beyond PET/CT and SPECT/CT
    Cherry, Simon R.
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2009, 39 (05) : 348 - 353
  • [4] Multimodality molecular imaging with combined optical and SPECT/PET modalities
    Culver, Joseph
    Akers, Walter
    Achilefu, Samuel
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (02) : 169 - 172
  • [5] Technical and methodological issues in preclinical imaging with PET and SPECT
    Lecchi, M.
    Belloli, S.
    Moresco, R. M.
    Lui, R.
    Del Sole, A.
    Fazio, F.
    Lucignani, G.
    [J]. MINERVA BIOTECNOLOGICA, 2009, 21 (02) : 123 - 134
  • [6] Protocols for Dual Tracer PET/SPECT Preclinical Imaging
    Blower, Julia E.
    Bordoloi, Jayanta K.
    Rigby, Alex
    Farleigh, Matthew
    Kim, Jana
    O'Brien, Hugh
    Jackson, Jonathan
    Poyiatzis, Constantinos
    Bezer, James
    Sunassee, Kavitha
    Blower, Philip J.
    Livieratos, Lefteris
    [J]. FRONTIERS IN PHYSICS, 2020, 8
  • [7] REDUCED ISOTOPE DOSE AND RAPID IMAGING SPECT MPI WITH EXCELLENT IMAGE QUALITY
    Duvall, William Lane
    Croft, Lori B.
    Godiwala, Tapan
    Ginsberg, Eric
    George, Titus
    Henzlova, Milena J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [8] Simultaneous PET/SPECT imaging with shared detector on an existing preclinical PET scanner
    Wu, Jing
    Chen, Si
    Liu, Yaqiang
    Wang, Shi
    Ma, Tianyu
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [9] VECTor: A Preclinical Imaging System for Simultaneous Submillimeter SPECT and PET
    Goorden, Marlies C.
    van der Have, Frans
    Kreuger, Rob
    Ramakers, Ruud M.
    Vastenhouw, Brendan
    Burbach, J. Peter H.
    Booij, Jan
    Molthoff, Carla F. M.
    Beekman, Freek J.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (02) : 306 - 312
  • [10] Multimodality molecular imaging - Improving image quality
    Tian, Jie
    Bai, Jing
    Yan, Xiu-Ping
    Bao, Shanglian
    Li, Yinghui
    Liang, Wei
    Yang, Xin
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2008, 27 (05): : 48 - 57