VECTor: A Preclinical Imaging System for Simultaneous Submillimeter SPECT and PET

被引:82
|
作者
Goorden, Marlies C. [1 ]
van der Have, Frans [1 ,2 ]
Kreuger, Rob [1 ]
Ramakers, Ruud M. [1 ,2 ]
Vastenhouw, Brendan [1 ,2 ]
Burbach, J. Peter H. [3 ]
Booij, Jan [4 ]
Molthoff, Carla F. M. [5 ,6 ]
Beekman, Freek J. [1 ,2 ]
机构
[1] Delft Univ Technol, NL-2629 JB Delft, Netherlands
[2] MILabs, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Rudolf Magnus Inst Neurosci, Utrecht, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Nucl Med, NL-1105 AZ Amsterdam, Netherlands
[5] Vrije Univ Amsterdam, Med Ctr, Dept Nucl Med, Amsterdam, Netherlands
[6] PET Res, Amsterdam, Netherlands
关键词
pinhole; SPECT; PET; small-animal; molecular imaging; neuroimaging; cardiac imaging; ULTRA-HIGH-RESOLUTION; PERFORMANCE EVALUATION; MICROPET SCANNER; PINHOLE; RECONSTRUCTION; DESIGN;
D O I
10.2967/jnumed.112.109538
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Today, PET and SPECT tracers cannot be imaged simultaneously at high resolutions but require 2 separate imaging systems. This paper introduces a Versatile Emission Computed Tomography system (VECTor) for radionuclides that enables simultaneous submillimeter imaging of single-photon and positron-emitting radiolabeled molecules. Methods: gamma-photons produced both by electron-positron annihilation and by single-photon emitters are projected onto the same detectors by means of a novel cylindric high-energy collimator containing 162 narrow pinholes that are grouped in clusters. This collimator is placed in an existing SPECT system (U-SPECT-II) with 3 large-field-of-view gamma-detectors. From the acquired projections, PET and SPECT images are obtained using statistical image reconstruction that corrects for energy-dependent system blurring. Results: For PET tracers, the tomographic resolution obtained with a Jaszczak hot rod phantom was less than 0.8 mm, and 0.5-mm resolution images of SPECT tracers were acquired simultaneously. SPECT images were barely degraded by the simultaneous presence of a PET tracer, even when the activity concentration of the PET tracer exceeded that of the SPECT tracer by up to a factor of 2.5. Furthermore, we simultaneously acquired fully registered 3- and 4-dimensional multiple functional images from living mice that, in the past, could be obtained only sequentially. Conclusion: High-resolution complementary information about tissue function contained in SPECT and PET tracer distributions can now be obtained simultaneously using a fully integrated imaging device. These combined unique capabilities pave the way for new perspectives in imaging the biologic systems of rodents.
引用
收藏
页码:306 / 312
页数:7
相关论文
共 50 条
  • [1] Simultaneous PET/SPECT imaging with shared detector on an existing preclinical PET scanner
    Wu, Jing
    Chen, Si
    Liu, Yaqiang
    Wang, Shi
    Ma, Tianyu
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [2] Development of a SiPM based preclinical PET SPECT imaging system imaging system
    Ma, Tianyu
    Xu, Tianpeng
    Liu, Hui
    Wei, Qingyang
    Peng, Fan
    Deng, Zhi
    Gong, Guanghua
    Gong, Hui
    Wang, Shi
    Liu, Yaqiang
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [3] Technical and methodological issues in preclinical imaging with PET and SPECT
    Lecchi, M.
    Belloli, S.
    Moresco, R. M.
    Lui, R.
    Del Sole, A.
    Fazio, F.
    Lucignani, G.
    [J]. MINERVA BIOTECNOLOGICA, 2009, 21 (02) : 123 - 134
  • [4] Protocols for Dual Tracer PET/SPECT Preclinical Imaging
    Blower, Julia E.
    Bordoloi, Jayanta K.
    Rigby, Alex
    Farleigh, Matthew
    Kim, Jana
    O'Brien, Hugh
    Jackson, Jonathan
    Poyiatzis, Constantinos
    Bezer, James
    Sunassee, Kavitha
    Blower, Philip J.
    Livieratos, Lefteris
    [J]. FRONTIERS IN PHYSICS, 2020, 8
  • [5] SimPET: a Preclinical PET Insert for Simultaneous PET/MR Imaging
    Son, Jeong-Whan
    Kim, Kyeong Yun
    Park, Ji Yong
    Kim, Kyuwan
    Lee, Yun-Sang
    Ko, Guen Bae
    Lee, Jae Sung
    [J]. MOLECULAR IMAGING AND BIOLOGY, 2020, 22 (05) : 1208 - 1217
  • [6] SimPET: a Preclinical PET Insert for Simultaneous PET/MR Imaging
    Jeong-Whan Son
    Kyeong Yun Kim
    Ji Yong Park
    Kyuwan Kim
    Yun-Sang Lee
    Guen Bae Ko
    Jae Sung Lee
    [J]. Molecular Imaging and Biology, 2020, 22 : 1208 - 1217
  • [7] Simultaneous SPECT/MR Imaging with a SiPM-Based Preclinical Insert
    Carminati, M.
    Baratelli, F. M.
    Massara, M.
    Occhipinti, M.
    Nagy, K.
    Nyitrai, Z.
    Czeller, M.
    Kuehne, A.
    Niendorf, T.
    Valtorta, S.
    Belloli, S.
    Moresco, R. M.
    Savi, A.
    Iadanza, A.
    Falini, A.
    Politi, L. S.
    Cadioli, M.
    Fiorini, C.
    [J]. 2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [8] High resolution simultaneous SPECT-PET imaging in rats
    Vaissier, Pieter
    van der Have, Frans
    Goorden, Marlies
    Ivashchenko, Oleksandra
    Vastenhouw, Brendan
    Ramakers, Ruud
    Beekman, Frederik
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [9] Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging
    Keiichi Magota
    Naoki Kubo
    Yuji Kuge
    Ken-ichi Nishijima
    Songji Zhao
    Nagara Tamaki
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 742 - 752
  • [10] Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging
    Magota, Keiichi
    Kubo, Naoki
    Kuge, Yuji
    Nishijima, Ken-ichi
    Zhao, Songji
    Tamaki, Nagara
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (04) : 742 - 752