Protocols for Dual Tracer PET/SPECT Preclinical Imaging

被引:5
|
作者
Blower, Julia E. [1 ]
Bordoloi, Jayanta K. [1 ]
Rigby, Alex [1 ]
Farleigh, Matthew [1 ]
Kim, Jana [1 ]
O'Brien, Hugh [1 ]
Jackson, Jonathan [1 ]
Poyiatzis, Constantinos [1 ]
Bezer, James [1 ]
Sunassee, Kavitha [1 ]
Blower, Philip J. [1 ]
Livieratos, Lefteris [1 ]
机构
[1] Kings Coll London, St Thomas Hosp, Sch Biomed Engn & Imaging Sci, London, England
来源
FRONTIERS IN PHYSICS | 2020年 / 8卷
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
SPECT; PET; radionuclide; phantom; multi-modality; dual-radionuclide; dead-time; scatter; ISOTOPE;
D O I
10.3389/fphy.2020.00126
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Background: Multi-tracer PET/SPECT imaging enables different modality tracers to be present simultaneously, allowing multiple physiological processes to be imaged in the same subject, within a short time-frame. Fluorine-18 and technetium-99m, two commonly used PET and SPECT radionuclides, respectively, possess different emission profiles, offering the potential for imaging one in the presence of the other. However, the impact of the presence of each radionuclide on scanning the other could be significant and lead to confounding results. Here we use combinations of F-18 and Tc-99m to explore the challenges posed by dual tracer PET/SPECT imaging, and investigate potential practical ways to overcome them. Methods: Mixed-radionuclide F-18/Tc-99m phantom PET and SPECT imaging experiments were carried out to determine the crossover effects of each radionuclide on the scans using Mediso nanoScan PET/CT and SPECT/CT small animal scanners. Results: PET scan image quality and quantification were adversely affected by Tc-99m activities higher than 100 MBq due to a high singles rate increasing dead-time of the detectors. Below 100 MBq Tc-99m, PET scanner quantification accuracy was preserved. SPECT scan image quality and quantification were adversely affected by the presence of F-18 due to Compton scattering of 511 keV photons leading to over-estimation of Tc-99m activity and increased noise. However, Tc-99m:F-18 activity ratios of > 70:1 were found to mitigate this effect completely on the SPECT. A method for correcting for Compton scatter was also explored. Conclusion: Suitable combinations of injection sequence and imaging sequence can be devised to meet specific experimental multi-tracer imaging needs, with only minor or insignificant effects of each radionuclide on the scan of the other.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Ready for prime time? Dual tracer PET and SPECT imaging
    El Fakhri, Georges
    [J]. AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 2 (04): : 415 - 417
  • [2] Initial studies of PET-SPECT dual-tracer imaging
    Shao, Yiping
    Yao, Rutao
    Ma, Tianyu
    Manchiraju, Phani
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4198 - +
  • [3] Simultaneous SPECT and PET dual-tracer imaging using beam stopper device
    Lin, H. H.
    Chuang, K. S.
    Chien, C. H.
    Lue, K. H.
    Chiang, C. C.
    Jan, M. L.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S314 - S315
  • [4] Dual tracer imaging of SPECT and PET probes in living mice using a sequential protocol
    Chapman, Sarah E.
    Diener, Justin M.
    Sasser, Todd A.
    Correcher, Carlos
    Gonzalez, Antonio J.
    Van Avermaete, Tony
    Leevy, W. Matthew
    [J]. AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 2 (04): : 405 - 414
  • [5] SPECT and PET Protocols for Imaging Myocardial Viability
    Sciagrà R.
    [J]. Current Cardiovascular Imaging Reports, 2014, 7 (6) : 1 - 10
  • [6] Technical and methodological issues in preclinical imaging with PET and SPECT
    Lecchi, M.
    Belloli, S.
    Moresco, R. M.
    Lui, R.
    Del Sole, A.
    Fazio, F.
    Lucignani, G.
    [J]. MINERVA BIOTECNOLOGICA, 2009, 21 (02) : 123 - 134
  • [7] Simultaneous PET/SPECT imaging with shared detector on an existing preclinical PET scanner
    Wu, Jing
    Chen, Si
    Liu, Yaqiang
    Wang, Shi
    Ma, Tianyu
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [8] VECTor: A Preclinical Imaging System for Simultaneous Submillimeter SPECT and PET
    Goorden, Marlies C.
    van der Have, Frans
    Kreuger, Rob
    Ramakers, Ruud M.
    Vastenhouw, Brendan
    Burbach, J. Peter H.
    Booij, Jan
    Molthoff, Carla F. M.
    Beekman, Freek J.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (02) : 306 - 312
  • [9] Noise properties of simultaneous dual tracer PET imaging
    Verhaeghe, J.
    D'Asseler, Y.
    Staelens, S.
    Lemahieu, I.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2611 - 2614
  • [10] PET and SPECT dual-tracer imaging: Correction of 511keV photon's down-scatter effect on SPECT
    Ma, Tianyu
    Shao, Yiping
    Yao, Rutao
    Manchiraju, Phani
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3404 - 3407