Dose Reduction in Pediatric Computed Tomography with Automated Exposure Control

被引:30
|
作者
Alibek, Sedat [1 ]
Brand, Martin [2 ]
Suess, Christoph [3 ]
Wuest, Wolfgang [1 ]
Uder, Michael [1 ]
Greess, Holger [4 ]
机构
[1] Univ Erlangen Nurnberg, Inst Radiol, Erlangen, Germany
[2] Klinikum Nordoberpfalz AG, Dept Neurol, Weiden, Germany
[3] Siemens Healthcare, Forchheim, Germany
[4] Kreiskliniken Esslingen, Clin Diagnost Radiol, Ruit, Germany
关键词
Computed tomography; pediatric; dose reduction; image quality; MULTISLICE SPIRAL CT; TUBE CURRENT;
D O I
10.1016/j.acra.2011.01.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Since the introduction of computed tomographic (CT) imaging in the 1970s, the number of examinations has increased steadily. CT imaging is an essential part of routine workup in diagnostic radiology. The great advantage of multidetector computed tomography is the acquisition of a large amount of data in a short time period, thus speeding up diagnostic procedures. To protect patients from unnecessary radiation exposure, different approaches have been developed. In this study, the efficacy of automated exposure control (AEC) software in multidetector CT imaging with a focus on dose reduction in pediatric examinations was assessed. Materials and Methods: Between August 2004 and September 2005, a total of 71 children (40 male, 31 female; age range, 2-13 years; mean age, 7.2 years) were examined using a multisource CT scanner. Three different regions (chest, upper abdomen, and pelvis) were examined. Overall image quality was assessed with a subjective scale (1 = excellent, 2 = diagnostic, 3 = nondiagnostic). For all examinations, AEC was used. From the scanner's patient protocol, dose-length product, volume CT dose index, and tube current-time product were calculated for each examination. Results: With AEC, a mean dose reduction of 30.6% was calculated. Images were rated as excellent (n = 39) or diagnostic (n = 32). Nondiagnostic image quality was not seen. Dose-length product and volume CT dose index were reduced by 30.4% and 29.5%, respectively. Overall, a mean dose reduction of 30.1% of the effective dose (5.8 +/- 3.1 vs 8.4 +/- 4.6 mSv) was achieved (P < .001). Conclusions: With AEC software, a mean dose reduction of 30% without any loss in diagnostic image quality is possible.
引用
收藏
页码:690 / 693
页数:4
相关论文
共 50 条
  • [11] Management of auto exposure control during pediatric computed tomography
    Dianna D. Cody
    Pediatric Radiology, 2014, 44 : 427 - 430
  • [12] Optimization of a protocol in pediatric Computed tomography with automatic exposure control
    Miller-Clemente, Rafael
    Perez-Diaz, Marlen
    Lores Guevara, Manuel
    Ortega Rodriguez, Odalis
    Nepite Haber, Rosana
    Grinan Hernandez, Oraelis
    Guillama Llossas, Ayme
    IMAGEN DIAGNOSTICA, 2014, 5 (01): : 10 - 16
  • [13] Utilization of computed tomography in pediatric temporal fractures: A dose reduction approach
    Kamrava, Brandon
    Shah, Viraj N.
    Torres, Leonardo
    Sidani, Charif
    Saigal, Gaurav
    Hoffer, Michael E.
    Szczupak, Mikhaylo B.
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2023, 44 (02)
  • [14] Strategies for Computed Tomography Radiation Dose Reduction in Pediatric Neuroimaging Comment
    Flannery, Ann Marie
    Selden, Nathan R.
    NEUROSURGERY, 2015, 77 (02) : 232 - 232
  • [15] Automatic Exposure Control in Pediatric and Adult Computed Tomography Examinations Can We Estimate Organ and Effective Dose From Mean mAs Reduction?
    Papadakis, Antonios E.
    Perisinakis, Kostas
    Oikonomou, Ismini
    Damilakis, John
    INVESTIGATIVE RADIOLOGY, 2011, 46 (10) : 654 - 662
  • [16] Dose reduction in abdominal computed tomography
    Toepker, M.
    Ringl, H.
    RADIOLOGE, 2012, 52 (10): : 919 - +
  • [17] Dose reduction in multislice computed tomography
    Hundt, W
    Rust, F
    Stäbler, A
    Wolff, H
    Suess, C
    Reiser, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (01) : 140 - 147
  • [18] Reducing radiation dose in emergency computed tomography with automatic exposure control techniques
    Kalra M.K.
    Rizzo S.M.R.
    Novelline R.A.
    Emergency Radiology, 2005, 11 (5) : 267 - 274
  • [20] Dose Reduction and Dose Management in Computed Tomography - State of the Art
    Zinsser, Dominik
    Marcus, Roy
    Othman, Ahmed E.
    Bamberg, Fabian
    Nikolaou, Konstantin
    Flohr, Thomas
    Notohamiprodjo, Mike
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2018, 190 (06): : 531 - 540