Reducing radiation dose in emergency computed tomography with automatic exposure control techniques

被引:61
|
作者
Kalra M.K. [1 ]
Rizzo S.M.R. [1 ]
Novelline R.A. [1 ]
机构
[1] Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, Founders 215
关键词
Automatic exposure control; Computed tomography (CT); Radiation dose;
D O I
10.1007/s10140-004-0395-7
中图分类号
学科分类号
摘要
Computed tomography (CT) scanning is being increasingly used for evaluation of trauma, which most commonly involves younger individuals. As younger patients are at higher risk for radiation-induced cancer compared to older patients, radiation dose reduction is an important issue in emergency CT scanning. With automatic exposure control techniques, users select a desired image quality and the system adapts tube current to obtain the desired image quality with greater radiation dose efficiency. These techniques can help in reducing radiation dose by 10-60% in most instances. This review article presents a comprehensive description of fundamentals, clinical applications and radiation dose benefits of automatic exposure control in emergency CT scanning. © ASER 2005.
引用
收藏
页码:267 / 274
页数:7
相关论文
共 50 条
  • [1] Chest Computed Tomography Radiation Dose Optimization Comparison of Automatic Exposure Control Strength Curves
    Gyssels, Elodie
    Bohy, Pascale
    Cornil, Arnaud
    van Muylem, Alain
    Howarth, Nigel
    Gevenois, Pierre A.
    Tack, Denis
    JOURNAL OF THORACIC IMAGING, 2016, 31 (01) : 23 - 28
  • [2] Computed Tomography Radiation Dose Optimization: Scanning Protocols and Clinical Applications of Automatic Exposure Control
    Kalra, Mannudeep K.
    Naz, Nausheen
    Rizzo, Stefania M. R.
    Blake, Michael A.
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2005, 34 (05) : 171 - 181
  • [3] Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography
    Gerber, TC
    Kuzo, RS
    Morin, RL
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (01): : 165 - 176
  • [4] Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography
    Thomas C. Gerber
    Ronald S. Kuzo
    Richard L. Morin
    The International Journal of Cardiovascular Imaging, 2005, 21 : 165 - 176
  • [5] Radiation Exposure and Computed Tomography in the Emergency Department
    Rhoda, June E.
    ADVANCED EMERGENCY NURSING JOURNAL, 2008, 30 (03) : 271 - 282
  • [6] Reducing computed tomography radiation dose in diagnosing pulmonary embolism
    AL-Rammah, Tamader Y.
    Alohaly, Amani
    Albatsh, Kamal
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2016, 32 (06) : 1444 - 1448
  • [7] Options for reducing patient radiation dose with cardiovascular computed tomography
    Halliburton, Sandra Simon
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 153 - 164
  • [8] Options for reducing patient radiation dose with cardiovascular computed tomography
    Sandra Simon Halliburton
    The International Journal of Cardiovascular Imaging, 2009, 25 : 153 - 164
  • [9] Radiation exposure in spiral computed tomography -: Dose distribution and dose reduction
    Hidajat, N
    Mäurer, J
    Schröder, RJ
    Wolf, M
    Vogl, T
    Felix, R
    INVESTIGATIVE RADIOLOGY, 1999, 34 (01) : 51 - 57
  • [10] Dose reduction by automatic exposure control in multidetector computed tomography: comparison between measurement and calculation
    Lechel, U.
    Becker, C.
    Langenfeld-Jaeger, G.
    Brix, G.
    EUROPEAN RADIOLOGY, 2009, 19 (04) : 1027 - 1034