Dose Reduction in Pediatric Computed Tomography with Automated Exposure Control

被引:30
|
作者
Alibek, Sedat [1 ]
Brand, Martin [2 ]
Suess, Christoph [3 ]
Wuest, Wolfgang [1 ]
Uder, Michael [1 ]
Greess, Holger [4 ]
机构
[1] Univ Erlangen Nurnberg, Inst Radiol, Erlangen, Germany
[2] Klinikum Nordoberpfalz AG, Dept Neurol, Weiden, Germany
[3] Siemens Healthcare, Forchheim, Germany
[4] Kreiskliniken Esslingen, Clin Diagnost Radiol, Ruit, Germany
关键词
Computed tomography; pediatric; dose reduction; image quality; MULTISLICE SPIRAL CT; TUBE CURRENT;
D O I
10.1016/j.acra.2011.01.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Since the introduction of computed tomographic (CT) imaging in the 1970s, the number of examinations has increased steadily. CT imaging is an essential part of routine workup in diagnostic radiology. The great advantage of multidetector computed tomography is the acquisition of a large amount of data in a short time period, thus speeding up diagnostic procedures. To protect patients from unnecessary radiation exposure, different approaches have been developed. In this study, the efficacy of automated exposure control (AEC) software in multidetector CT imaging with a focus on dose reduction in pediatric examinations was assessed. Materials and Methods: Between August 2004 and September 2005, a total of 71 children (40 male, 31 female; age range, 2-13 years; mean age, 7.2 years) were examined using a multisource CT scanner. Three different regions (chest, upper abdomen, and pelvis) were examined. Overall image quality was assessed with a subjective scale (1 = excellent, 2 = diagnostic, 3 = nondiagnostic). For all examinations, AEC was used. From the scanner's patient protocol, dose-length product, volume CT dose index, and tube current-time product were calculated for each examination. Results: With AEC, a mean dose reduction of 30.6% was calculated. Images were rated as excellent (n = 39) or diagnostic (n = 32). Nondiagnostic image quality was not seen. Dose-length product and volume CT dose index were reduced by 30.4% and 29.5%, respectively. Overall, a mean dose reduction of 30.1% of the effective dose (5.8 +/- 3.1 vs 8.4 +/- 4.6 mSv) was achieved (P < .001). Conclusions: With AEC software, a mean dose reduction of 30% without any loss in diagnostic image quality is possible.
引用
收藏
页码:690 / 693
页数:4
相关论文
共 50 条
  • [31] Reduction Of Uterus Dose In Clinical Thoracic Computed Tomography
    Danova, D.
    Keil, B.
    Kastner, B.
    Wulff, J.
    Fiebich, M.
    Zink, K.
    Klose, K. J.
    Heverhagen, J. T.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (12): : 1091 - 1096
  • [32] Streak Artifact Reduction in Low Dose Computed Tomography
    Zamyatin, Alexander A.
    Yang, Zhi
    Akino, Naruomi
    Nakanishi, Satoru
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4150 - +
  • [33] New dose reduction techniques for thoracic computed tomography
    Revel, M. -P.
    REVUE DES MALADIES RESPIRATOIRES, 2013, 30 (02) : 161 - 164
  • [34] Automated Organ Dose Calculation for Thousands of Computed Tomography Scans
    Lee, C.
    Lamart, S.
    Miglioretti, D.
    Johnson, E.
    Kruger, R.
    Flynn, M.
    Weinmann, S.
    Smith-Bindman, R.
    MEDICAL PHYSICS, 2012, 39 (06) : 3924 - 3925
  • [35] Radiation dose reduction in pediatric computed tomography (CT) using deep convolutional neural network denoising
    Horst, K. K.
    Zhou, Z.
    Hull, N. C.
    Thacker, P. G.
    Kassmeyer, B. A.
    Johnson, M. P.
    Demirel, N.
    Missert, A. D.
    Weger, K.
    Yu, L.
    CLINICAL RADIOLOGY, 2025, 80
  • [36] Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography
    Johannes Boos
    Patric Kröpil
    Dirk Klee
    Philipp Heusch
    Lars Schimmöller
    Jörg Schaper
    Gerald Antoch
    Rotem S. Lanzman
    Pediatric Radiology, 2014, 44 : 1065 - 1069
  • [37] Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography
    Boos, Johannes
    Kroepil, Patric
    Klee, Dirk
    Heusch, Philipp
    Schimmoeller, Lars
    Schaper, Joerg
    Antoch, Gerald
    Lanzman, Rotem S.
    PEDIATRIC RADIOLOGY, 2014, 44 (09) : 1065 - 1069
  • [38] Dual-Energy Computed Tomography Dose Reduction, Series Reduction, and Contrast Load Reduction in Dual-Energy Computed Tomography
    Parakh, Anushri
    Macri, Francesco
    Sahani, Dushyant
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 601 - +
  • [39] Chest Computed Tomography Radiation Dose Optimization Comparison of Automatic Exposure Control Strength Curves
    Gyssels, Elodie
    Bohy, Pascale
    Cornil, Arnaud
    van Muylem, Alain
    Howarth, Nigel
    Gevenois, Pierre A.
    Tack, Denis
    JOURNAL OF THORACIC IMAGING, 2016, 31 (01) : 23 - 28
  • [40] Computed Tomography Radiation Dose Optimization: Scanning Protocols and Clinical Applications of Automatic Exposure Control
    Kalra, Mannudeep K.
    Naz, Nausheen
    Rizzo, Stefania M. R.
    Blake, Michael A.
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2005, 34 (05) : 171 - 181