Background current elimination in thin layer ion-selective membrane coulometry

被引:29
|
作者
Grygolowicz-Pawlak, Ewa [1 ]
Bakker, Eric [1 ]
机构
[1] Curtin Univ Technol, Dept Chem, Nanochem Res Inst, Perth, WA 6845, Australia
基金
美国国家卫生研究院; 澳大利亚研究理事会;
关键词
Ion-selective electrode; Calcium ionophore; Ion transfer voltammetry; Calibration free sensing; Thin layer coulometry; Polypropylene hollow fiber membrane; INTERFACE; ELECTROLYSIS; VOLTAMMETRY; SENSORS;
D O I
10.1016/j.elecom.2010.06.017
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A promising method for the elimination of undesired capacitive currents in view of realizing a potentially calibration free coulometric ion detection system is presented. The coulometric cell is composed of a porous polypropylene tube doped with a liquid calcium-selective membrane and a silver/silver chloride wire as an inner electrode, forming a thin layer sample between wire and tubing. The total charge passed through the system during potential controlled electrolysis of the thin layer sample is indeed found to be proportional to the amount of calcium present, but non-Faradaic processes do contribute to the obtained signal. We introduce here a multi-pulse procedure that allows one to perform a second excitation pulse at the same excitation potential after exhaustive ion transfer voltammetry of calcium has taken place. The intercept of the calibration curve after background subtraction is found as 20.6 +/- 0.6 mu C. significantly lower than the value of 54.1 +/- 0.8 mu C for the uncorrected curve. Changes in sample temperature (from 23 C degrees to 38 degrees C) did equally not affect the background corrected coulometric readings, supporting that the procedure renders the readout principle more robust. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1195 / 1198
页数:4
相关论文
共 50 条
  • [1] Thin Layer Coulometry of Nitrite with Ion-Selective Membranes
    Afshar, Majid Ghahraman
    Crespo, Gaston A.
    Dorokhin, Denis
    Neel, Bastien
    Bakker, Eric
    ELECTROANALYSIS, 2015, 27 (03) : 609 - 615
  • [2] Thin Layer Coulometry with Ionophore Based Ion-Selective Membranes
    Grygolowicz-Pawlak, Ewa
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2010, 82 (11) : 4537 - 4542
  • [3] Detection Limits of Thin Layer Coulometry with lonophore Based Ion-Selective Membranes
    Shvarev, Alexey
    Neel, Bastien
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2012, 84 (18) : 8038 - 8044
  • [4] Membrane Response Model for Ion-Selective Electrodes Operated by Controlled-Potential Thin-Layer Coulometry
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2011, 83 (02) : 486 - 493
  • [5] Approaching to Calibration-Free Ion Detection Based on Thin Layer Coulometry with Ultrathin Ion-Selective Membranes
    Liu, Yujie
    Crespo, Gaston A.
    Cuartero, Maria
    ACS MEASUREMENT SCIENCE AU, 2024, 5 (01): : 63 - 69
  • [6] Thin layer coulometry ion sensing protocol with potassium-selective membrane electrodes
    Grygolowicz-Pawlak, Ewa
    Bakker, Eric
    ELECTROCHIMICA ACTA, 2011, 56 (28) : 10359 - 10363
  • [7] Operational limits of controlled current coulometry with ion-selective polymeric membranes
    Bhakthavatsalam, Vishnupriya
    Bakker, Eric
    ELECTROANALYSIS, 2008, 20 (03) : 225 - 232
  • [8] Interference Compensation for Thin Layer Coulometric Ion-Selective Membrane Electrodes by the Double Pulse Technique
    Grygolowicz-Pawlak, Ewa
    Numnuam, Apon
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2012, 84 (03) : 1327 - 1335
  • [9] Effect of convective flow on the current efficiency of an ion-selective membrane
    Hsu, JP
    Hsieh, YH
    JOURNAL OF THE CHINESE INSTITUTE OF CHEMICAL ENGINEERS, 2003, 34 (01): : 115 - 122
  • [10] ION-SELECTIVE MEMBRANE ELECTRODES
    VALLON, JJ
    LYON PHARMACEUTIQUE, 1975, 26 (05): : 487 - 500