Thin Layer Coulometry with Ionophore Based Ion-Selective Membranes

被引:71
|
作者
Grygolowicz-Pawlak, Ewa [1 ]
Bakker, Eric [1 ]
机构
[1] Curtin Univ Technol, Nanochem Res Inst, Dept Chem, Perth, WA 6845, Australia
基金
澳大利亚研究理事会; 美国国家卫生研究院;
关键词
LIQUID-MEMBRANE; BULK OPTODES; SENSORS; ELECTRODES; INTERFACE; POTENTIOMETRY; ELECTROLYSIS; TITRATIONS; VIEW; LEAD;
D O I
10.1021/ac100524z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We are demonstrating here for the first time a thin layer coulometric detection mode for ionophore based liquid ion-selective membranes. Coulometry promises to achieve the design of robust, calibration free sensors that are especially attractive for applications where recalibration in situ is difficult or undesirable. This readout principle is here achieved with porous polypropylene tubing doped with the membrane material and which contains a chlorinated silver wire in the inner compartment, together with the fluidically delivered sample solution. The membrane material consists of the lipophilic plasticizer dodecyl 2-nitrophenyl ether, the lipophilic electrolyte ETH 500, and the calcium ionophore ETH 5234. Importantly and in contrast to earlier work on voltammetric liquid membrane electrodes, the membrane also contains a cation-exchanger salt, KTFPB. This renders the membrane permselective and allows one to observe open circuit potentiometric responses for the device, which is confirmed to follow the expected Nernstian equation. Moreover, as the same cationic species is now potential determining at both interfaces of the membrane, it is possible to use rapidly diffusing and/or thin membrane systems where transport processes at the inner and outer interface of the membrane do not perturb each other or the overall composition of the membrane. The tubing is immersed in an electrolyte solution where the counter and working electrode are placed, and the potentials are applied relative to the measured open circuit potentials. Exhaustive current decays are observed in the range of 10 to 100 mu M calcium chloride. The observed charge, calculated as integrated currents, is linearly dependent on concentration and forms the basis for the coulometric readout of ion-selective membrane electrodes.
引用
收藏
页码:4537 / 4542
页数:6
相关论文
共 50 条
  • [1] Thin Layer Coulometry of Nitrite with Ion-Selective Membranes
    Afshar, Majid Ghahraman
    Crespo, Gaston A.
    Dorokhin, Denis
    Neel, Bastien
    Bakker, Eric
    ELECTROANALYSIS, 2015, 27 (03) : 609 - 615
  • [2] Detection Limits of Thin Layer Coulometry with lonophore Based Ion-Selective Membranes
    Shvarev, Alexey
    Neel, Bastien
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2012, 84 (18) : 8038 - 8044
  • [3] Approaching to Calibration-Free Ion Detection Based on Thin Layer Coulometry with Ultrathin Ion-Selective Membranes
    Liu, Yujie
    Crespo, Gaston A.
    Cuartero, Maria
    ACS MEASUREMENT SCIENCE AU, 2024, 5 (01): : 63 - 69
  • [4] Dynamic electrochemistry with ionophore based ion-selective membranes
    Crespo, Gaston A.
    Bakker, Eric
    RSC ADVANCES, 2013, 3 (48): : 25461 - 25474
  • [5] Background current elimination in thin layer ion-selective membrane coulometry
    Grygolowicz-Pawlak, Ewa
    Bakker, Eric
    ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (09) : 1195 - 1198
  • [6] Operational limits of controlled current coulometry with ion-selective polymeric membranes
    Bhakthavatsalam, Vishnupriya
    Bakker, Eric
    ELECTROANALYSIS, 2008, 20 (03) : 225 - 232
  • [7] Problems and prospects of solid contact ion-selective electrodes with ionophore-based membranes
    N. M. Ivanova
    M. B. Levin
    K. N. Mikhelson
    Russian Chemical Bulletin, 2012, 61 : 926 - 936
  • [8] Problems and prospects of solid contact ion-selective electrodes with ionophore-based membranes
    Ivanova, N. M.
    Levin, M. B.
    Mikhelson, K. N.
    RUSSIAN CHEMICAL BULLETIN, 2012, 61 (05) : 926 - 936
  • [9] Current response of ionophore-based ion-selective electrode membranes at controlled potential
    Morf, WE
    Zwickl, T
    Pretsch, E
    de Rooij, NF
    CHIMIA, 2003, 57 (10) : 639 - 642
  • [10] Mathematical model of current-polarized ionophore-based ion-selective membranes
    Zook, Justin M.
    Buck, Richard P.
    Langmaier, Jan
    Lindner, Erno
    JOURNAL OF PHYSICAL CHEMISTRY B, 2008, 112 (07): : 2008 - 2015