Operational limits of controlled current coulometry with ion-selective polymeric membranes

被引:10
|
作者
Bhakthavatsalam, Vishnupriya [1 ]
Bakker, Eric [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
chemically selective coulometry; ion-selective membrane; chronopotentiometry; electrochemical reagent delivery; ionophore;
D O I
10.1002/elan.200703979
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Plasticized polymeric membrane electrodes containing selective chemical receptors (ionophores) that are used in potentiometric and optical sensors have recently been shown to be attractive in controlled current coulometry for calibration free reagent delivery. For this purpose, a galvanostatic pulse of fixed duration is applied across an ion-selective membrane containing added ion-exchanger sites, resulting in the release of a calculated amount of ions from the membrane into the sample phase. This paper evaluates the operational limits of such coulometric actuators with chronopotentiometry, using silver-selective membranes as model systems. Diffusion theory predicts the depletion of ionophore and ion-exchanger at one of the two interfaces in a matter of minutes, owing to the relatively small diffusion coefficients in such membranes. Chronopotentiometry on membranes containing lipophilic cations at either side of the membrane, rather than silver ions, confirms that the ionophore depletes at the inner side of the membrane. At the sample side, ionophore is expected to increase in concentration and does not result in a loss of selectivity. Chronopotentiometric responses show a drastic transition at long times, typically 30 min, which cannot plausibly be explained by the depletion of added lipophilic ion-exchanger at the sample side since the diffusion coefficients are similar to that of ionophore. It is postulated that the intrinsic anion-exchanger sites of the PVC matrix are relatively immobile and do not easily concentration polarize upon application of a transmembrane current pulse, in agreement with Buck's earlier work on fixed site membranes. Indeed, silver and calcium-selective membranes fabricated with increased concentrations of such fixed sites, by using carboxylated PVC, exhibited chronopotentiometric breakdown times larger than 60 min and no loss in coulometric efficiency. The results obtained here will help in designing coulometric actuators with improved characteristics on the basis of hydrophobic polymeric ion-selective membranes.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 50 条
  • [1] Current response of ion-selective solvent polymeric membranes at controlled potential
    Sutter, J
    Morf, WE
    de Rooij, NF
    Pretsch, E
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 571 (01) : 27 - 35
  • [2] Detection Limits of Thin Layer Coulometry with lonophore Based Ion-Selective Membranes
    Shvarev, Alexey
    Neel, Bastien
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2012, 84 (18) : 8038 - 8044
  • [3] Thin Layer Coulometry of Nitrite with Ion-Selective Membranes
    Afshar, Majid Ghahraman
    Crespo, Gaston A.
    Dorokhin, Denis
    Neel, Bastien
    Bakker, Eric
    ELECTROANALYSIS, 2015, 27 (03) : 609 - 615
  • [4] Thin Layer Coulometry with Ionophore Based Ion-Selective Membranes
    Grygolowicz-Pawlak, Ewa
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2010, 82 (11) : 4537 - 4542
  • [5] Background current elimination in thin layer ion-selective membrane coulometry
    Grygolowicz-Pawlak, Ewa
    Bakker, Eric
    ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (09) : 1195 - 1198
  • [6] DEVELOPMENT OF POLYMERIC MEMBRANES FOR ZINC ION-SELECTIVE ELECTRODES
    FIEDLERLINNERSUND, U
    BHATTI, KM
    ANALYTICA CHIMICA ACTA, 1979, 111 (01) : 57 - 70
  • [7] Effects of controlled current on the response behavior of polymeric membrane ion-selective electrodes
    Morf, WE
    Badertscher, M
    Zwickl, T
    de Rooij, NF
    Pretsch, E
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2): : 19 - 28
  • [8] COMBINATION ION-SELECTIVE ELECTRODE BASED ON SOLVENT POLYMERIC MEMBRANES
    DOHNER, RE
    SIMON, W
    ANALYTICAL LETTERS, 1979, 12 (03) : 205 - 212
  • [9] Properties of ion-selective electrodes with polymeric membranes for ketoprofen determination
    Lenik, J.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 67 (06) : 543 - 549
  • [10] Temperature dependence of electrical conductivity of ion-selective polymeric membranes
    Saldaze, G.K.
    Bazikova, G.D.
    Balavadze, E.M.
    Colloid journal of the USSR, 1989, 50 (04): : 628 - 632