Background current elimination in thin layer ion-selective membrane coulometry

被引:29
|
作者
Grygolowicz-Pawlak, Ewa [1 ]
Bakker, Eric [1 ]
机构
[1] Curtin Univ Technol, Dept Chem, Nanochem Res Inst, Perth, WA 6845, Australia
基金
美国国家卫生研究院; 澳大利亚研究理事会;
关键词
Ion-selective electrode; Calcium ionophore; Ion transfer voltammetry; Calibration free sensing; Thin layer coulometry; Polypropylene hollow fiber membrane; INTERFACE; ELECTROLYSIS; VOLTAMMETRY; SENSORS;
D O I
10.1016/j.elecom.2010.06.017
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A promising method for the elimination of undesired capacitive currents in view of realizing a potentially calibration free coulometric ion detection system is presented. The coulometric cell is composed of a porous polypropylene tube doped with a liquid calcium-selective membrane and a silver/silver chloride wire as an inner electrode, forming a thin layer sample between wire and tubing. The total charge passed through the system during potential controlled electrolysis of the thin layer sample is indeed found to be proportional to the amount of calcium present, but non-Faradaic processes do contribute to the obtained signal. We introduce here a multi-pulse procedure that allows one to perform a second excitation pulse at the same excitation potential after exhaustive ion transfer voltammetry of calcium has taken place. The intercept of the calibration curve after background subtraction is found as 20.6 +/- 0.6 mu C. significantly lower than the value of 54.1 +/- 0.8 mu C for the uncorrected curve. Changes in sample temperature (from 23 C degrees to 38 degrees C) did equally not affect the background corrected coulometric readings, supporting that the procedure renders the readout principle more robust. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1195 / 1198
页数:4
相关论文
共 50 条
  • [21] ION-SELECTIVE MEMBRANE ELECTRODES - A REVIEW
    PUNGOR, E
    TOTH, K
    ANALYST, 1970, 95 (1132) : 625 - &
  • [22] WATER AND THE ION-SELECTIVE ELECTRODE MEMBRANE
    HARRISON, DJ
    LI, XZ
    PETROVIC, S
    ACS SYMPOSIUM SERIES, 1992, 487 : 292 - 300
  • [23] POTASSIUM ION-SELECTIVE LIQUID MEMBRANE
    BAND, DM
    KRATOCHV.J
    JOURNAL OF PHYSIOLOGY-LONDON, 1974, 239 (01): : P10 - P10
  • [24] THE SURFACE-MORPHOLOGY OF ION-SELECTIVE MEMBRANE ELECTRODES .3. STUDIES ON THE LEAD ION-SELECTIVE MEMBRANE
    PUNGOR, E
    TOTH, K
    NAGY, G
    POLOS, L
    EBEL, MF
    WERNISCH, I
    ANALYTICA CHIMICA ACTA, 1983, 147 (MAR) : 23 - 32
  • [25] Effects of controlled current on the response behavior of polymeric membrane ion-selective electrodes
    Morf, WE
    Badertscher, M
    Zwickl, T
    de Rooij, NF
    Pretsch, E
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2): : 19 - 28
  • [26] Regulating the Polypyrrole Ion-Selective Membrane and Au Solid Contact Layer to Improve the Performance of Nitrate All-Solid Ion-Selective Electrodes
    Gao, Weizhuo
    Jing, Weixuan
    Du, Yanrui
    Li, Zehao
    Liu, Pengcheng
    Han, Feng
    Zhao, Libo
    Yang, Zhaochu
    Jiang, Zhuangde
    MICROMACHINES, 2023, 14 (04)
  • [27] ION-SELECTIVE MEMBRANE ELECTRODES - MECHANISMS AND ION ASSOCIATION
    RECHNITZ, GA
    ACTA PHARMACEUTICA SUECICA, 1972, 9 (06): : 638 - 639
  • [28] Current-Driven Ion Fluxes of Polymeric Membrane Ion-Selective Electrode for Potentiometric Biosensing
    Ding, Jiawang
    Qin, Wei
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (41) : 14640 - +
  • [29] ROTATED MERCURY CELL FOR CONTROLLED POTENTIAL COULOMETRY - ELIMINATION OF BACKGROUND CURRENT BY DIGITAL NORMALIZATION
    CLEM, RG
    JAKOB, F
    ANDERBER.DH
    ORNELAS, LD
    ANALYTICAL CHEMISTRY, 1971, 43 (11) : 1398 - &
  • [30] Immunoenzymatic sensitisation of membrane ion-selective electrodes
    Koncki, R
    Owczarek, A
    Dzwolak, W
    Glab, S
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 47 (1-3) : 246 - 250