Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability

被引:9
|
作者
Parchani, Gaurav [1 ]
Kumar, Gulshan [2 ]
Rao, Raghavendra [3 ]
Udupa, Kaviraja [2 ]
Saran, Vibhor [1 ]
机构
[1] Turtle Shell Technol Pvt Ltd, City Ctr 40,Ground & Mezzanine Floor, Bengaluru 560038, Karnataka, India
[2] Natl Inst Mental Hlth & Neuro Sci NIMHANS, Dept Neurophysiol, Bengaluru, Karnataka, India
[3] Cent Council Res Yoga & Naturopathy, Dept Res, Delhi, India
关键词
Autonomic nervous system balance; Ballistocardiography; Heart rate variability; Parasympathetic nervous system; Sympathetic nervous system;
D O I
10.1177/09727531211063426
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Functions of the autonomic nervous system have cardinal importance in day-to-day life. Heart rate variability (HRV) has been shown to estimate the functioning of the autonomic nervous system. Imbalance in the functioning of the autonomic nervous system is seen to be associated with chronic conditions such as chronic kidney disease, cardiovascular diseases, diabetes mellitus, and so on. Purpose: To evaluate the efficacy of a non-contact ballistocardiography (BCG) system to calculate HRV parameters by comparing them to the parameters derived from a standard commercial software that uses an electrocardiogram (ECG). Methods: Current study captured an ECG signal using a three-channel ECG Holter machine, whereas the BCG signal was captured using a BCG sensor sheet consisting of vibroacoustic sensors placed under the mattress of the participants of the study. Results: The study was conducted on 24 subjects for a total of 54 overnight recordings. The proposed method covered 97.92% epochs of the standard deviation of NN intervals (SDNN) and 99.27% epochs of root mean square of successive differences (RMSSD) within 20 ms and 30 ms tolerance, respectively, whereas 98.84% of two-min intervals for low-frequency (LF) to high-frequency (HF) ratio was covered within a tolerance of 1. Kendall's coefficient of concordance was also calculated, giving a P < .001 for all the three parameters and coefficients 0.66, 0.55, and 0.44 for SDNN, RMSSD, and LF/HF, respectively. Conclusion: The results show that HRV parameters captured using unobtrusive and non-invasive BCG sensors are comparable to HRV calculated using ECG.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 50 条
  • [31] Contact and Non-contact Heart Beat Rate Measurement Techniques: Challenges and Issues
    Khong, Wei Leong
    Mariappan, Muralindran
    Chong, Chee Siang
    PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY, 2021, 29 (03): : 1707 - 1732
  • [32] Development of Non-contact Monitoring System of Heart Rate Variability (HRV) - An Approach of Remote Sensing for Ubiquitous Technology
    Suzuki, Satoshi
    Matsui, Takemi
    Gotoh, Shinji
    Mori, Yasutaka
    Takase, Bonpei
    Ishihara, Masayuki
    ERGONOMICS AND HEALTH ASPECTS OF WORK WITH COMPUTERS, 2009, 5624 : 195 - +
  • [33] Second Harmonic Weighted Reconstruction for Non-Contact Monitoring Heart Rate
    Zheng, Pengwei
    Zheng, Chundi
    Li, Xiaoxia
    Chen, Huihui
    Wang, Aiguo
    Luo, Yihong
    IEEE SENSORS JOURNAL, 2022, 22 (06) : 5815 - 5823
  • [34] A Comparative Study of Video Signals for Non-contact Heart Rate Measurement
    Lueangwattana, Chanya
    Kondo, Toshiaki
    Haneishi, Hideaki
    2015 12TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2015,
  • [35] Non-contact Heart Rate Monitoring Using Multiple RGB Cameras
    Ghanadian, Hamideh
    Al Osman, Hussein
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, CAIP 2019, PT II, 2019, 11679 : 85 - 95
  • [36] A Non-Contact Photoplethysmography Technique for the Estimation of Heart Rate via Smartphone
    Maestre-Rendon, J. Rodolfo
    Rivera-Roman, Tomas A.
    Fernandez-Jaramillo, Arturo A.
    Guerron Paredes, Nancy E.
    Serrano Olmedo, Jose Javier
    APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [37] Non-contact Heart Rate Estimation in Pediatric Intensive Care Units
    Bal, Ufuk
    Bal, Alkan
    2014 18TH NATIONAL BIOMEDICAL ENGINEERING MEETING (BIYOMUT), 2014,
  • [38] A non-contact ECG measurement system for pervasive heart rate detection
    Zhu, Da-Huan
    Wang, Lei
    Zhang, Yuan-Ting
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 551 - 552
  • [39] Non-Contact Heart Rate Monitoring Using Lab Color Space
    Rahman, Hamidur
    Ahmed, Mobyen Uddin
    Begum, Shahina
    PHEALTH 2016, 2016, 224 : 46 - 53
  • [40] Non-Contact Heart Rate Monitoring Based on Millimeter Wave Radar
    Ling, Zongquan
    Zhou, Weinan
    Ren, Yuhao
    Wang, Jiping
    Guo, Liquan
    IEEE Access, 2022, 10 : 74033 - 74044