Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability

被引:9
|
作者
Parchani, Gaurav [1 ]
Kumar, Gulshan [2 ]
Rao, Raghavendra [3 ]
Udupa, Kaviraja [2 ]
Saran, Vibhor [1 ]
机构
[1] Turtle Shell Technol Pvt Ltd, City Ctr 40,Ground & Mezzanine Floor, Bengaluru 560038, Karnataka, India
[2] Natl Inst Mental Hlth & Neuro Sci NIMHANS, Dept Neurophysiol, Bengaluru, Karnataka, India
[3] Cent Council Res Yoga & Naturopathy, Dept Res, Delhi, India
关键词
Autonomic nervous system balance; Ballistocardiography; Heart rate variability; Parasympathetic nervous system; Sympathetic nervous system;
D O I
10.1177/09727531211063426
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Functions of the autonomic nervous system have cardinal importance in day-to-day life. Heart rate variability (HRV) has been shown to estimate the functioning of the autonomic nervous system. Imbalance in the functioning of the autonomic nervous system is seen to be associated with chronic conditions such as chronic kidney disease, cardiovascular diseases, diabetes mellitus, and so on. Purpose: To evaluate the efficacy of a non-contact ballistocardiography (BCG) system to calculate HRV parameters by comparing them to the parameters derived from a standard commercial software that uses an electrocardiogram (ECG). Methods: Current study captured an ECG signal using a three-channel ECG Holter machine, whereas the BCG signal was captured using a BCG sensor sheet consisting of vibroacoustic sensors placed under the mattress of the participants of the study. Results: The study was conducted on 24 subjects for a total of 54 overnight recordings. The proposed method covered 97.92% epochs of the standard deviation of NN intervals (SDNN) and 99.27% epochs of root mean square of successive differences (RMSSD) within 20 ms and 30 ms tolerance, respectively, whereas 98.84% of two-min intervals for low-frequency (LF) to high-frequency (HF) ratio was covered within a tolerance of 1. Kendall's coefficient of concordance was also calculated, giving a P < .001 for all the three parameters and coefficients 0.66, 0.55, and 0.44 for SDNN, RMSSD, and LF/HF, respectively. Conclusion: The results show that HRV parameters captured using unobtrusive and non-invasive BCG sensors are comparable to HRV calculated using ECG.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 50 条
  • [21] Non-contact Measurement of Heart Rate Based on Facial Video
    Wang, Cheng
    Jiang, Yuling
    Cai, Zhuohao
    Lin, Lan
    2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - FALL (PIERS - FALL), 2019, : 2269 - 2275
  • [22] Non-Contact Remote Measurement of Heart Rate Variability using Near-Infrared Photoplethysmography Imaging
    Yu, Xinchi
    Paul, Michael
    Antink, Christoph Hoog
    Venema, Boudewijn
    Blazek, Vladimir
    Bollheimer, Cornelius
    Leonhardt, Steffen
    Teichmann, Daniel
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 846 - 849
  • [23] Non-contact video-based estimation of heart rate variability spectrogram from hemoglobin composition
    Fukunishi M.
    Kurita K.
    Yamamoto S.
    Tsumura N.
    Artificial Life and Robotics, 2017, 22 (4) : 457 - 463
  • [24] Non-contact Heart Rate Measurements Based on Skin Detection
    Zhao Ting
    Zhou Zuofeng
    Chen Pengyong
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [25] Non-contact Heart Rate Measurement based on Camera Image
    Kitajima, Toshihiro
    Choi, SangOn
    Murakami, Edwardo Arata Y.
    JOURNAL OF INFORMATION ASSURANCE AND SECURITY, 2015, 10 (03): : 120 - 129
  • [26] Non-contact Heart Rate Monitoring with Mobile Phone Camera
    Lin, Shu-Yen
    Tsai, Meng-Ru
    2019 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - TAIWAN (ICCE-TW), 2019,
  • [27] The Non-Contact Heart Rate Measurement System for Monitoring HRV
    Huang, Ji-Jer
    Yu, Sheng-, I
    Syu, Hao-Yi
    See, Aaron Raymond
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3238 - 3241
  • [28] Motion-compensated non-contact detection of heart rate
    Yang, Lei
    Liu, Ming
    Dong, Liquan
    Zhao, Yuejin
    Liu, Xiaohua
    OPTICS COMMUNICATIONS, 2015, 357 : 161 - 168
  • [29] Uncertainty Measurements in Non-Contact Neonatal Heart Rate Monitoring
    Dosso, Yasmina Souley
    Greenwood, Kimberley J.
    Harrold, Joann
    Green, James R.
    IEEE ACCESS, 2023, 11 : 144168 - 144179
  • [30] Non-contact Heart Rate Estimation from a Video Sequence
    Taralunga, Dragos Daniel
    Nicolae, Irina
    Hurezeanu, Bogdan
    Ungureanu, Mihaela
    Strungaru, Rodica
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2016), 2016, : 348 - 351