Stability analysis of Three-phase Grid-Connected inverter under the weak grids with asymmetrical grid impedance by LTP theory in time domain

被引:72
|
作者
Lin, Xianfu [1 ,2 ]
Liu, Yupeng [1 ,2 ]
Yu, Jingrong [3 ]
Yu, Ruoxue [4 ]
Zhang, Junhao [1 ,2 ]
Wen, He [1 ,2 ]
机构
[1] Hunan Univ, Coll Elect & Informat Engn, Changsha, Peoples R China
[2] Hunan Prov Key Lab Intelligent Elect Measurement, Changsha, Peoples R China
[3] Cent South Univ, Hunan Prov Key Lab Power Elect Equipment & Grid, Sch Automat, Changsha, Peoples R China
[4] Jiangxi Univ Engn, Coll Artificial Intelligence, Xinyu City, Peoples R China
关键词
Grid-connected inverter; asymmetrical grid impedance; Phase Lock Loop; harmonic state-space model; stability boundaries; participation factors; PLL;
D O I
10.1016/j.ijepes.2022.108244
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Grid-connected inverter (GCI) often operates in the weak grid with asymmetrical grid impedance due to the unbalanced and single-phase loads. However, the time-periodic dynamic behavior effect of the Phase-Locked Loop (PLL) on the GCI operating in an asymmetrical system is not investigated in the time domain. This paper explores the influence of the asymmetrical grid impedance on the stability of the weak grid with GCI. Firstly, GCI's complete harmonic state-space (HSS) model considering PLL under the asymmetrical network is established. Secondly, in view of the developed HSS model, the predominant parameters are determined through the eigenvalues of the system state matrix, along with the participation factors. Afterward, with eigenvalue locus analysis, the stability boundaries of the system's critical parameters involving the current reference, current controller, and PLL controller are determined under different grid impedance asymmetrical indexes. It is found that the stability region of system parameters is narrowed with increasing impedance asymmetrical index. Lastly, simulations and experiments are carried out to verify the effectiveness of the proposed HSS model and the theoretical analysis results.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Performance Analysis of Grid-Connected Three-Phase Three-Level NPC Inverter
    Kharedia, Ravina
    Batra, Rupanshi
    2018 IEEE 8TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2018,
  • [42] Impedance Modeling and Output Impedance Coupling Analysis of Three-Phase Grid-Connected Inverters
    Yang, Wen
    Wang, Mingyu
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 1355 - 1359
  • [43] Stability Analysis for the Grid-Connected Single-Phase Asymmetrical Cascaded Multilevel Inverter With SRF-PI Current Control Under Weak Grid Conditions
    Han, Yang
    Chen, Hao
    Li, Zipeng
    Yang, Ping
    Xu, Lin
    Guerrero, Josep M.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (03) : 2052 - 2069
  • [44] IMPEDANCE SHAPING OF GRID-CONNECTED THREE-PHASE PV SYSTEMS
    Silva, P. O.
    Nunes, E. A. F.
    Rocha, T. O. A.
    Costa, F. B.
    2017 XIV BRAZILIAN POWER ELECTRONICS CONFERENCE (COBEP), 2017,
  • [45] Frequency Coupling Suppression Control Method for Three-Phase Grid-Connected Converter Under Weak Grid
    Zhang X.
    Xia D.
    Chen W.
    Chen L.
    Xu D.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (21): : 4559 - 4571
  • [46] A Low-Loss Grid Decoupling Mechanism in a Three-Phase Grid-Connected Inverter
    Wang, Bangchao
    He, Yuanbin
    Shen, Lei
    Xie, Xiaogao
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 1730 - 1735
  • [47] Nonlinear Stability Analysis for Three-Phase Grid-Connected PV Generators
    Wei, Wei
    Xia, Yanghong
    Blaabjerg, Frede
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2020, 8 (04) : 3487 - 3501
  • [48] Impedance Modeling and Stability Analysis of Three-Phase Four-Leg Grid-Connected Inverter Considering Zero-Sequence
    Nian, Heng
    Liao, Yuming
    Li, Meng
    Sun, Dan
    Xu, Yunyang
    Hu, Bin
    IEEE ACCESS, 2021, 9 : 83676 - 83687
  • [49] The Control Strategy for the Grid-Connected Inverter Through Impedance Reshaping in q-Axis and its Stability Analysis Under a Weak Grid
    Li, Ming
    Zhang, Xing
    Guo, Zixuan
    Wang, Jilei
    Wang, Yang
    Li, Fei
    Zhao, Wei
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (03) : 3229 - 3242
  • [50] Stability Analysis of LCL-type Grid-connected Inverter in Weak Grid Systems
    Chen, Xin
    Gong, Chun Yin
    Wang, Hui Zhen
    Cheng, Lin
    INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,