Stability analysis of Three-phase Grid-Connected inverter under the weak grids with asymmetrical grid impedance by LTP theory in time domain

被引:72
|
作者
Lin, Xianfu [1 ,2 ]
Liu, Yupeng [1 ,2 ]
Yu, Jingrong [3 ]
Yu, Ruoxue [4 ]
Zhang, Junhao [1 ,2 ]
Wen, He [1 ,2 ]
机构
[1] Hunan Univ, Coll Elect & Informat Engn, Changsha, Peoples R China
[2] Hunan Prov Key Lab Intelligent Elect Measurement, Changsha, Peoples R China
[3] Cent South Univ, Hunan Prov Key Lab Power Elect Equipment & Grid, Sch Automat, Changsha, Peoples R China
[4] Jiangxi Univ Engn, Coll Artificial Intelligence, Xinyu City, Peoples R China
关键词
Grid-connected inverter; asymmetrical grid impedance; Phase Lock Loop; harmonic state-space model; stability boundaries; participation factors; PLL;
D O I
10.1016/j.ijepes.2022.108244
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Grid-connected inverter (GCI) often operates in the weak grid with asymmetrical grid impedance due to the unbalanced and single-phase loads. However, the time-periodic dynamic behavior effect of the Phase-Locked Loop (PLL) on the GCI operating in an asymmetrical system is not investigated in the time domain. This paper explores the influence of the asymmetrical grid impedance on the stability of the weak grid with GCI. Firstly, GCI's complete harmonic state-space (HSS) model considering PLL under the asymmetrical network is established. Secondly, in view of the developed HSS model, the predominant parameters are determined through the eigenvalues of the system state matrix, along with the participation factors. Afterward, with eigenvalue locus analysis, the stability boundaries of the system's critical parameters involving the current reference, current controller, and PLL controller are determined under different grid impedance asymmetrical indexes. It is found that the stability region of system parameters is narrowed with increasing impedance asymmetrical index. Lastly, simulations and experiments are carried out to verify the effectiveness of the proposed HSS model and the theoretical analysis results.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Sequence admittance modeling and stability analysis for three-phase LCL-type grid-connected inverter with DC bus and MFC disturbance under weak grid
    Zhu Y.
    Pu J.
    Ge X.
    Yan P.
    Sun W.
    Li T.
    Liu C.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (09): : 190 - 196
  • [22] Improving Small-Signal Stability of Grid-Connected Inverter Under Weak Grid by Decoupling Phase-Lock Loop and Grid Impedance
    Lin, Xianfu
    Yu, Jingrong
    Yu, Ruoxue
    Zhang, Junhao
    Yan, Zhongzong
    Wen, He
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (07) : 7040 - 7053
  • [23] Impedance-based Analysis of Grid-connected Inverter in high Impedance Grids
    Chen, Xin
    Chen, Jie
    Gong, ChunYing
    Wang, HuiZhen
    PROCEEDINGS OF THE 2013 IEEE 8TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2013, : 1284 - 1289
  • [24] Asymmetrical Grid Fault Ride-Through Strategy of Three-Phase Grid-Connected Inverter Considering Network Impedance Impact in Low-Voltage Grid
    Guo, Xiaoqiang
    Zhang, Xue
    Wang, Baocheng
    Wu, Weiyang
    Guerrero, Josep M.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) : 1064 - 1068
  • [25] Impedance Modeling and Stability Analysis of a Three-phase Three-level NPC Inverter Connected to the Grid
    Zhang, Bo
    Du, Xiong
    Zhao, Jingbo
    Zhou, Jiapei
    Zou, Xiaoming
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2020, 6 (02): : 270 - 278
  • [26] Modeling and Control of a Three-phase Grid-connected Inverter under Fault Conditions
    Rolan, Alejandro
    Gimenez, Pablo
    Yague, Sauro J.
    Bogrra, Santiago
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2018, : 479 - 484
  • [27] Stability analysis of three-phase PV inverter under inductive grid impedance condition
    Li, Xiaoqiang
    Wu, Xiaojie
    Geng, Yiwen
    Zhang, Qi
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (18): : 2906 - 2916
  • [28] New Perspectives on Stability Analysis of Three-Phase Grid-Connected Inverter Considering System Couplings
    Yu, Jingrong
    Lin, Xianfu
    Song, Dongran
    Yu, Ruoxue
    Yang, Jian
    Su, Mei
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (03) : 1967 - 1978
  • [29] Oscillation Suppression Strategy of Three-Phase Four-Wire Grid-Connected Inverter in Weak Power Grid
    Feng, Guoli
    Ye, Zhihao
    Xia, Yihui
    Nian, Heng
    Jiang, Yunxiang
    ELECTRONICS, 2023, 12 (14)
  • [30] Three-Phase Boost-Type Grid-Connected Inverter
    Chen, Yang
    Smedley, Keyue
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (05) : 2301 - 2309