Feasibility and improvement of a three-dimensional printed navigation template for modified cortical bone trajectory screw placement in the lumbar spine

被引:4
|
作者
Shi, Wenjie [1 ]
Aini, Mijiti [2 ]
Dang, Limin [1 ]
Kahaer, Alafate [3 ]
Zhou, Zhihao [3 ]
Wang, Yixi [1 ]
Maimaiti, Abulikemu [3 ]
Wang, Shuiquan [4 ]
Guo, Hailong [3 ]
Rexiti, Paerhati [3 ]
机构
[1] Xinjiang Med Univ, Xinjiang Uygur Autonomous Reg, Urumqi, Peoples R China
[2] Second Peoples Hosp Kashgar Dist, Xinjiang Uygur Autonomous Reg, Dept Orthoped, Kashgar City, Peoples R China
[3] Xinjiang Med Univ, Affiliated Hosp 1, Dept Spine Surg, Xinjiang Uygur Autonomous Reg, Urumqi, Peoples R China
[4] Xinjiang Med Univ, Coll Basic Med, Dept Anat, Xinjiang Uygur Autonomous Reg, Urumqi, Peoples R China
来源
FRONTIERS IN SURGERY | 2022年 / 9卷
关键词
spine implants; lumbar vertebra; 3D printing; reverse engineering; cortical bone trajectory; 3D navigation template; STRENGTH; FIXATION; DENSITY;
D O I
10.3389/fsurg.2022.1028276
中图分类号
R61 [外科手术学];
学科分类号
摘要
ObjectivesCompared with traditional pedicle screw trajectory, cortical bone trajectory (CBT) increases the contact surface between the screw and cortical bone where the screw is surrounded by dense cortical bone, which does not deform remarkably due to degeneration. We aimed to provide detailed information about the improvement of three-dimensional (3D)-printed navigation templates for modified CBT screw placement in the lumbar spine and evaluate the safety and accuracy thereof. MethodsFour human cadaveric lumbar spine specimens were selected. After CT scanning data were reconstructed to 3D models, either the left or right side of each specimen was randomly selected to establish a 3D-navigation template, mutually complemented with the surface anatomical structure of the lateral margin of the lumbar isthmus, vertebral plate, and spinous process. The corresponding 3D centrum was printed according to the CT scanning data, and a navigation template of supporting design was made according to modified cortical bone technique. The same template was used to insert CBT screws into 3D printed and cadaveric specimens. After the screws were inserted, the screw path of the 3D printed specimens was directly observed, and that of the anatomical specimens was scanned by CT, to determine the position and direction of the screws to analyze the success rate of screw placement. ResultsTwenty cortical bone screws were placed in each of the 3D printed and anatomical specimens, with excellent rates of screw placement of 100% and 95%, respectively. ConclusionsWe report the easy, safe, accurate, and reliable use of a 3D-printed navigation template to carry out screw placement by modified cortical bone technique in the lumbar spine.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Clinical Application of Atlantoaxial Pedicle Screw Placement Assisted by a Modified 3D-Printed Navigation Template
    Pu, Xingwei
    Luo, Chunshan
    Lu, Tinsheng
    Yao, Shudan
    Chen, Qiling
    CLINICS, 2018, 73
  • [22] The three-dimensional printed template guided technique for S2 alar iliac screw placement and a comparison with freehand technique
    Zhou, Zhenhai
    Zeng, Zhimin
    Yu, Honggui
    Xiong, Jiachao
    Liu, Zhiming
    Zhou, Rongping
    Wan, Wenbing
    Pan, Zhimin
    Chen, Lu
    Cao, Kai
    JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (03)
  • [23] Reliability of three-dimensional fluoroscopy for detecting pedicle screw violations in the thoracic and lumbar spine
    Wang, MY
    Kim, KA
    Liu, CY
    Kim, P
    Apuzzo, MLJ
    NEUROSURGERY, 2004, 54 (05) : 1138 - 1142
  • [24] Biomechanical Evaluation of Cortical Bone Trajectory Fixation with Traditional Pedicle Screw in the Lumbar Spine: A Finite Element Study
    Su, Kuo-Chih
    Chen, Kun-Hui
    Pan, Chien-Chou
    Lee, Cheng-Hung
    APPLIED SCIENCES-BASEL, 2021, 11 (22):
  • [25] Axial translaminar screw placement using three-dimensional fluoroscopy-based navigation
    Rajasekaran, S.
    Avadhani, A.
    Shetty, A. P.
    SINGAPORE MEDICAL JOURNAL, 2011, 52 (01) : 15 - 18
  • [26] A 3D-CT Study of the Cortical Bone Trajectory Screw Placement Parameters Based on Lumbar CT
    Zeng, Weibo
    Hu, Shengxuan
    Zhu, Zhemin
    Wang, Shuai
    Guo, Lijun
    Shi, Benchao
    ORTHOPAEDIC SURGERY, 2024, 16 (11) : 2771 - 2780
  • [27] The feasibility of laminar screw placement in the subaxial spine: analysis using 215 three-dimensional computed tomography scans and simulation software
    Shin, Sang Ik
    Yeom, Jin S.
    Kim, Ho-Joong
    Chang, Bong-Soon
    Lee, Choon-Ki
    Riew, K. Daniel
    SPINE JOURNAL, 2012, 12 (07): : 577 - 584
  • [28] Comparing Cortical Bone Trajectories for Pedicle Screw Insertion using Robotic Guidance and Three-Dimensional Computed Tomography Navigation
    Khan, Asham
    Rho, Kyungduk
    Mao, Jennifer Z.
    O'Connor, Timothy E.
    Agyei, Justice O.
    Meyers, Joshua E.
    Mullin, Jeffrey P.
    Pollina, John
    WORLD NEUROSURGERY, 2020, 141 : E625 - E632
  • [29] Three-Dimensional Hounsfield Units Measurement of Pedicle Screw Trajectory for Predicating Screw Loosening in Lumbar Fusion Surgery
    Zhao, He
    Wang, Yan-jun
    Wang, Rui-guo
    Liu, Da
    Duan, Ya-qing
    Liu, Yang-jin
    Zeng, Yu-hong
    Zhao, Qin-peng
    Zhang, Zheng-ping
    CLINICAL INTERVENTIONS IN AGING, 2023, 18 : 485 - 493
  • [30] Feasibility and accuracy of computer-assisted individual drill guide template for minimally invasive lumbar pedicle screw placement trajectory
    Wang, Hongwei
    Liu, Yusheng
    Zhao, Yiwen
    Song, Guoli
    Liu, Jun
    Han, Jianda
    Xiang, Liangbi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (03): : 644 - 648