Clinical Application of Atlantoaxial Pedicle Screw Placement Assisted by a Modified 3D-Printed Navigation Template

被引:10
|
作者
Pu, Xingwei [1 ]
Luo, Chunshan [1 ]
Lu, Tinsheng [1 ]
Yao, Shudan [1 ]
Chen, Qiling [1 ]
机构
[1] Guizhou Orthoped Hosp, Dept Spinal Surg, Guiyang 550002, Guizhou, Peoples R China
关键词
Atlantoaxial; Improvement; Navigation Template; 3D Print; Pedicle Screw; ACCURACY;
D O I
10.6061/clinics/2018/e259
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: To investigate the primary clinical value of atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template. METHODS: We retrospectively analyzed the cases of 17 patients treated from June 2015 to September 2016 with atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template. All procedures were performed prior to surgery, including thin-slice CT scanning, medical image sampling and computerized 3D modeling of the atlantoaxial joint, optimal pedicle screw trajectory determination, and anatomical trait acquisition for the atlantoaxial pedicle, spinous process of the axis, vertebral lamina and posterior lateral mass, and design of a reverse template. During surgery, a navigation template was tightly attached to the atlantoaxial joint to assist in pedicle screw placement. Surgeons subsequently used an electric drill to remove the template through a guide channel and then placed the atlantoaxial pedicle screw. Observed indexes included the VAS score, JOA improvement rate, surgery duration, and blood loss. RESULTS: Surgery was successful in all 17 patients, with an average operation duration of 106 +/- 25 min and an average blood loss of 220 +/- 125 ml. Three days postoperatively, the VAS score decreased from 6.42 +/- 2.21 to 3.15 +/- 1.26. Six months postoperatively, the score decreased to 2.05 +/- 1.56. The postoperative JOA score increased significantly from 7.68 +/- 2.51 to 11.65 +/- 2.72 3 d after surgery and to 13.65 +/- 2.57 after 6 months. Sixtyeight pedicle screws were inserted successfully, with 34 in the atlas and 34 in the axis. According to the Kawaguchi standard, 66 screws were in grade 0 (97.06%), and 2 were in grade 1 (2.94%). The pre- and postoperative transverse and sagittal screw angles showed no significant differences. CONCLUSIONS: Atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template is worth recommending due to the improved accuracy in screw placement, improved patient safety and beneficial clinical effects.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Design and basic research on accuracy of a novel individualized three-dimensional printed navigation template in atlantoaxial pedicle screw placement
    Chen, Xiao-Long
    Xie, Ya-Fen
    Li, Jian-Xin
    Wu, Wu
    Li, Guan-Nan
    Hu, Hui-Jing
    Wang, Xiao-Yun
    Meng, Zhao-Jian
    Wen, Yue-Feng
    Huang, Wen-Hua
    PLOS ONE, 2019, 14 (04):
  • [2] A Modified Personalized Image-Based Drill Guide Template for Atlantoaxial Pedicle Screw Placement: A Clinical Study
    Jiang, Lianghai
    Dong, Liang
    Tan, Mingsheng
    Qi, Yingna
    Yang, Feng
    Yi, Ping
    Tang, Xiangsheng
    MEDICAL SCIENCE MONITOR, 2017, 23 : 1325 - 1333
  • [3] 3D-printed guides versus computer navigation for pedicle screw placement in the surgical treatment of congenital scoliosis deformities
    Xu, Hui-Fa
    Li, Chao
    Tang, Guoliang
    Li, Tian-Qing
    Fan, Zong-Zhi
    Huang, Lu-Yu
    JOURNAL OF ORTHOPAEDIC SURGERY, 2024, 32 (01)
  • [4] Clinical Application of a 3D-Printed Positioning Module and Navigation Template for Percutaneous Vertebroplasty
    Yang, Jing
    Ni, Penghui
    Zhang, Lina
    Lu, Zhanxin
    Liu, Dapeng
    Mo, Fuhao
    Liu, Tang
    SURGICAL INNOVATION, 2022, 29 (06) : 760 - 768
  • [5] Mixed Reality-Based Navigation for Pedicle Screw Placement: A Preliminary Study Using a 3D-Printed Spine Model
    Ohashi, Masayuki
    Sato, Masayuki
    Tashi, Hideki
    Minato, Keitaro
    Makino, Tatsuo
    Kawashima, Hiroyuki
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [6] Clinical application of individualized 3D-printed navigation template to children with cubitus varus deformity
    Xinyue Hu
    Meiling Zhong
    Yue Lou
    Peng Xu
    Bo Jiang
    Fengyong Mao
    Dan Chen
    Pengfei Zheng
    Journal of Orthopaedic Surgery and Research, 15
  • [7] Clinical application of individualized 3D-printed navigation template to children with cubitus varus deformity
    Hu, Xinyue
    Zhong, Meiling
    Lou, Yue
    Xu, Peng
    Jiang, Bo
    Mao, Fengyong
    Chen, Dan
    Zheng, Pengfei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [8] Cervical pedicle screw placement with patient-specific 3D-printed guides: accuracy and safety in a clinical experience
    Marengo, Nicola
    Colonna, Stefano
    Lo Bue, Enrico
    Pesaresi, Alessandro
    Saaid, Ayoub
    Allevi, Mario
    Ajello, Marco
    Mahieu, Geert
    Garbossa, Diego
    Cofano, Fabio
    EUROPEAN SPINE JOURNAL, 2025, : 1248 - 1255
  • [9] Pedicle screw placement in spinal neurosurgery using a 3D-printed drill guide template: a systematic review and meta-analysis
    Chengqiang Yu
    Yufu Ou
    Chengxin Xie
    Yu Zhang
    Jianxun Wei
    Xiaoping Mu
    Journal of Orthopaedic Surgery and Research, 15
  • [10] Pedicle screw placement in spinal neurosurgery using a 3D-printed drill guide template: a systematic review and meta-analysis
    Yu, Chengqiang
    Ou, Yufu
    Xie, Chengxin
    Zhang, Yu
    Wei, Jianxun
    Mu, Xiaoping
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)