Clinical Application of Atlantoaxial Pedicle Screw Placement Assisted by a Modified 3D-Printed Navigation Template

被引:10
|
作者
Pu, Xingwei [1 ]
Luo, Chunshan [1 ]
Lu, Tinsheng [1 ]
Yao, Shudan [1 ]
Chen, Qiling [1 ]
机构
[1] Guizhou Orthoped Hosp, Dept Spinal Surg, Guiyang 550002, Guizhou, Peoples R China
关键词
Atlantoaxial; Improvement; Navigation Template; 3D Print; Pedicle Screw; ACCURACY;
D O I
10.6061/clinics/2018/e259
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: To investigate the primary clinical value of atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template. METHODS: We retrospectively analyzed the cases of 17 patients treated from June 2015 to September 2016 with atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template. All procedures were performed prior to surgery, including thin-slice CT scanning, medical image sampling and computerized 3D modeling of the atlantoaxial joint, optimal pedicle screw trajectory determination, and anatomical trait acquisition for the atlantoaxial pedicle, spinous process of the axis, vertebral lamina and posterior lateral mass, and design of a reverse template. During surgery, a navigation template was tightly attached to the atlantoaxial joint to assist in pedicle screw placement. Surgeons subsequently used an electric drill to remove the template through a guide channel and then placed the atlantoaxial pedicle screw. Observed indexes included the VAS score, JOA improvement rate, surgery duration, and blood loss. RESULTS: Surgery was successful in all 17 patients, with an average operation duration of 106 +/- 25 min and an average blood loss of 220 +/- 125 ml. Three days postoperatively, the VAS score decreased from 6.42 +/- 2.21 to 3.15 +/- 1.26. Six months postoperatively, the score decreased to 2.05 +/- 1.56. The postoperative JOA score increased significantly from 7.68 +/- 2.51 to 11.65 +/- 2.72 3 d after surgery and to 13.65 +/- 2.57 after 6 months. Sixtyeight pedicle screws were inserted successfully, with 34 in the atlas and 34 in the axis. According to the Kawaguchi standard, 66 screws were in grade 0 (97.06%), and 2 were in grade 1 (2.94%). The pre- and postoperative transverse and sagittal screw angles showed no significant differences. CONCLUSIONS: Atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template is worth recommending due to the improved accuracy in screw placement, improved patient safety and beneficial clinical effects.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Individualized 3D-printed navigation template-assisted tension band wiring for olecranon fractures
    Xu Xiong
    Ya-Ling Chen
    Lan Zhao
    Hao Li
    Min Xu
    Feng Shuang
    Journal of Orthopaedic Surgery and Research, 18
  • [22] Individualized 3D-printed navigation template-assisted tension band wiring for olecranon fractures
    Xiong, Xu
    Chen, Ya-Ling
    Zhao, Lan
    Li, Hao
    Xu, Min
    Shuang, Feng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [23] A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
    Chen, Hsuan-Yu
    Xiao, Xiu-Yun
    Chen, Chih-Wei
    Chou, Hao-Kai
    Sung, Chen-Yu
    Lin, Feng Huei
    Chen, Po-Quang
    Wong, Tze-hong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):
  • [24] Comparison of Perpendicular to the Coronal Plane versus Medial Inclination for C2 Pedicle Screw Insertion Assisted by 3D Printed Navigation Template
    Wu, Chao
    Deng, Jiayan
    Wang, Qing
    Shen, Danwei
    Qin, Binwei
    Li, Tao
    Wang, Xiangyu
    Zeng, Baifang
    ORTHOPAEDIC SURGERY, 2023, 15 (02) : 563 - 571
  • [25] Optimizing Lumbar Pedicle Screw Trajectory Utilizing a 3D-Printed Drill Guide to Ensure Placement of Pedicle Screws Into Higher Density Bone May Improve Pedicle Screw Pullout Resistance
    Zhao, Xin
    Zhao, Jie
    Sun, Xiao-Jiang
    Zhou, Xian-Hao
    Zhang, Kai
    Xie, You-Zhuan
    WORLD NEUROSURGERY, 2022, 158 : E459 - E464
  • [26] 3D-printed drill guide template, a promising tool to improve pedicle screw placement accuracy in spinal deformity surgery: A systematic review and meta-analysis
    Weishi Liang
    Bo Han
    Junrui Jonathan Hai
    Yong Hai
    Long Chen
    Nan Kang
    Peng Yin
    European Spine Journal, 2021, 30 : 1173 - 1183
  • [27] Comparative study of sacroiliac screw placement guided by 3D-printed template technology and X-ray fluoroscopy
    Wu Zhou
    Tian Xia
    Yi Liu
    Faqi Cao
    Mengfei Liu
    Jing Liu
    Bobin Mi
    Liangcong Hu
    Yuan Xiong
    Guohui Liu
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 11 - 17
  • [28] 3D-printed drill guide template, a promising tool to improve pedicle screw placement accuracy in spinal deformity surgery: A systematic review and meta-analysis
    Liang, Weishi
    Han, Bo
    Hai, Junrui Jonathan
    Hai, Yong
    Chen, Long
    Kang, Nan
    Yin, Peng
    EUROPEAN SPINE JOURNAL, 2021, 30 (05) : 1173 - 1183
  • [29] Comparative study of sacroiliac screw placement guided by 3D-printed template technology and X-ray fluoroscopy
    Zhou, Wu
    Xia, Tian
    Liu, Yi
    Cao, Faqi
    Liu, Mengfei
    Liu, Jing
    Mi, Bobin
    Hu, Liangcong
    Xiong, Yuan
    Liu, Guohui
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (01) : 11 - 17
  • [30] Individualized 3D printed navigation template-assisted atlantoaxial pedicle screws vs. free-hand screws for the treatment of upper cervical fractures
    Niu, Guoqi
    Cheng, Jiawei
    Liu, Lutan
    Li, Chao
    Zhou, Gong
    Chen, Hui
    Liu, Tao
    Nie, Hu
    Sun, Zheng
    Jiang, Weili
    Zhou, Qiankun
    Zhao, Baoyin
    Zhu, Jun
    Yu, Ruochen
    Guo, Yalong
    Yang, Yi
    Bai, Jianzhong
    FRONTIERS IN SURGERY, 2022, 9