Comparison of Perpendicular to the Coronal Plane versus Medial Inclination for C2 Pedicle Screw Insertion Assisted by 3D Printed Navigation Template

被引:2
|
作者
Wu, Chao [1 ,2 ]
Deng, Jiayan [2 ]
Wang, Qing [3 ]
Shen, Danwei [2 ]
Qin, Binwei [3 ]
Li, Tao [1 ]
Wang, Xiangyu [1 ]
Zeng, Baifang [1 ,3 ]
机构
[1] Zigong Fourth Peoples Hosp, Dept Orthoped, 19 Tanmu Lin St, Zigong 643000, Sichuan, Peoples R China
[2] Zigong Acad Big Data Med Sci & Artificial Intelli, Inst Digital Med, Zigong 643000, Peoples R China
[3] Hosp Southwest Med Univ, Dept Orthoped, Fuzhou, Peoples R China
关键词
Axis; Navigation templates; Pedicle screw; FIXATION; PLACEMENT; PARS; AXIS; FREEHAND; SAFETY; C1;
D O I
10.1111/os.13535
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective C2 pedicle screw insertion is very important in posterior upper cervical surgery. The traditional screw placement technique requires us to consider both medial inclination and cephalad angle, it is difficult to operate intraoperatively. This paper is to explore a novel method of C2 pedicle screw placement compared with traditional C2 pedicle screw. Methods A total of 44 patients diagnosed with atlantoaxial fracture or instability from May 2018 to November 2020 were involved in this retrospective study, and they were divided into C2-PPS group (perpendicular to the coronal plane C2 screw, 24 patients) and C2-TPS group (traditional C2 pedicle screw, 20 patients). The diameter of the maximum tangential circle, distance between geometric center and median sagittal plane and screw length of PPS and TPS were measured based on the 3D model of C2, respectively. Then the 3D printed navigation templated were designed and manufactured by 3D printing to assisted the PPS and TPS placement, respectively. The surgical time and radiation exposure times during operation were recorded; the post-operative grading criteria, deviation of screw entry point and deviation of screw angle of two groups were evaluated, respectively. Results A total of 48 screws were inserted in the C2-PPS group, and 40 screws were inserted in the C2-TPS group. There were 46 screws with grade 0 (95.8%) in the PPS group and 31 screws with grade 0 (77.5%) in the TPS group, (P = 0.03). The radiation exposure times in the C2-PPS group and C2-TPS group were 4.7 +/- 1.5 and 7.8 +/- 3.8, respectively, (P = 0.045). The deviations of screw entry point in the C2-PPS group and C2-TPS group were 1.2 +/- 0.8 mm and 3.2 +/- 1.3 mm, respectively; the deviations of screw angle in the C2-PPS group and C2-TPS group were 2.1 +/- 1.6 degrees and 4.8 +/- 2.0 degrees, respectively, (P = 0.000). The diameters of the maximum tangential circle in the C2-PPS group and C2-TPS group were 5.5 +/- 1.0 mm and 5.3 +/- 0.9 mm, respectively. The distances between the geometric center and median sagittal plane in the C2-PPS group and C2-TPS group were 15.4 +/- 2.3 mm and 18.0 +/- 3.3 mm, respectively; The screw lengths in the C2-PPS group and C2-TPS group were 25.9 +/- 3.2 mm and 27.6 +/- 3.7 mm, respectively, (P = 0.000). Conclusion Eighty percent of C2-PPS corridor can accommodate a 3.5 mm diameter screw, and with an average screw length of 26 mm. Navigation templates assisted the C2-PPS placement is less surgical time, less radiation exposure times, more safe and more accurate than C2-TPS.
引用
收藏
页码:563 / 571
页数:9
相关论文
共 31 条
  • [1] Comparison of perpendicular to the coronal plane versus medial inclination for atlas pedicle screw insertion: an anatomic and radiological study in human cadavers
    Ma, Jun
    Tang, Jian
    Wang, Deguang
    Zhu, Yucheng
    Sui, Tao
    Cao, Xiaojian
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (01) : 141 - 147
  • [2] Comparison of perpendicular to the coronal plane versus medial inclination for atlas pedicle screw insertion: an anatomic and radiological study in human cadavers
    Jun Ma
    Jian Tang
    Deguang Wang
    Yucheng Zhu
    Tao Sui
    Xiaojian Cao
    International Orthopaedics, 2016, 40 : 141 - 147
  • [3] A Comparative Study of C2 Pedicle or Pars Screw Placement with Assistance from a 3-Dimensional (3D)-Printed Navigation Template versus C-Arm Based Navigation
    Tian, Ye
    Zhang, Jianan
    Liu, Tuanjiang
    Tang, Shi
    Chen, Hao
    Ding, Keyuan
    Hao, Dingjun
    MEDICAL SCIENCE MONITOR, 2019, 25 : 9981 - 9990
  • [4] Feasibility of Atlas Pedicle Screw Fixation Perpendicular to the Coronal Plane-A 3D Anatomic Analysis
    Wu, Chao
    Deng, Jiayan
    Wang, Qing
    Pan, Jian
    Hu, Haigang
    Li, Guangzhou
    Tan, Lun
    Wei, Qin
    GLOBAL SPINE JOURNAL, 2022, 12 (07) : 1369 - 1374
  • [5] Clinical Application of Atlantoaxial Pedicle Screw Placement Assisted by a Modified 3D-Printed Navigation Template
    Pu, Xingwei
    Luo, Chunshan
    Lu, Tinsheng
    Yao, Shudan
    Chen, Qiling
    CLINICS, 2018, 73
  • [6] Comparison of Computer-Assisted Navigation and 3D Printed Patient-Specific Template for the Iliosacral Screw Placement
    Wan, Yizhou
    Xue, Peiran
    Yue, Junyi
    Yu, Keda
    Guo, Xiaodong
    Chen, Kaifang
    ORTHOPAEDIC SURGERY, 2023, 15 (11) : 2855 - 2863
  • [7] C2 pedicle screw placement on 3D-printed models for the performance assessment of CTA-based screw preclusion
    Wu, Yuelin
    Liang, Zhaoquan
    Bao, Junhao
    Wen, Ling
    Zhang, Li
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [8] C2 pedicle screw placement on 3D-printed models for the performance assessment of CTA-based screw preclusion
    Yuelin Wu
    Zhaoquan Liang
    Junhao Bao
    Ling Wen
    Li Zhang
    Journal of Orthopaedic Surgery and Research, 18
  • [9] Comparative study of 3D printed navigation template-assisted atlantoaxial pedicle screws versus free-hand screws for type II odontoid fractures
    Yang Li
    Jing Lin
    Yuan Wang
    Haotian Luo
    Jing Wang
    Sheng Lu
    Yongqing Xu
    European Spine Journal, 2021, 30 : 498 - 506
  • [10] Comparative study of 3D printed navigation template-assisted atlantoaxial pedicle screws versus free-hand screws for type II odontoid fractures
    Li, Yang
    Lin, Jing
    Wang, Yuan
    Luo, Haotian
    Wang, Jing
    Lu, Sheng
    Xu, Yongqing
    EUROPEAN SPINE JOURNAL, 2021, 30 (02) : 498 - 506