Reliability of three-dimensional fluoroscopy for detecting pedicle screw violations in the thoracic and lumbar spine

被引:34
|
作者
Wang, MY
Kim, KA
Liu, CY
Kim, P
Apuzzo, MLJ
机构
[1] Univ So Calif, Keck Sch Med, Dept Neurol Surg, Los Angeles, CA 90033 USA
[2] Univ So Calif, Keck Sch Med, Dept Neurol Surg, Los Angeles, CA USA
[3] Univ So Calif, Keck Sch Med, Dept Radiol, Los Angeles, CA USA
关键词
computed tomography; lumbar spine; minimally invasive; pedicle screws; thoracic spine;
D O I
10.1227/01.NEU.0000119330.70023.8F
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Thoracic and lumbar pedicle screws have become popular because of their biomechanical superiority over other methods of spinal fixation. However, the safety and efficacy of transpedicular screws depend on their proper placement. Recent advances in imaging have resulted in the ability to acquire three-dimensional (3-D) axial images of the spine during surgery, and this study was undertaken to assess the reliability of this technology to detect,pedicle violations. METHODS: Pedicle screws were placed in six human cadaver spines from T1 to S1 using standard techniques. Intentional pedicle violations were created in 74 of 216 pedicles, and violations were graded on a four-point scale (range, 0-3). Radiographic images were then obtained using a conventional spiral computed tomographic scanner and the Siremobil Iso-C 3D (Siemens Medical Solutions, Erlangen, Germany) 3-D fluoroscopy unit. An independent neuroradiologist then graded pedicle violations as ascertained by the two imaging modalities. RESULTS: Using direct inspection of the pedicles as the "gold standard," the overall sensitivity and specificity for detecting pedicle violations were 0.716 and 0.789, respectively, with 3-D fluoroscopy. The overall sensitivity and specificity for detecting pedicle violations were 0.608 and 0.937, respectively, with conventional computed tomography. All Grade 2 pedicle violations were detected in the thoracic spine by both modalities, and all Grade-3 violations were detected by both modalities. CONCLUSION: Axial images obtained with 3-D fluoroscopy demonstrate a higher sensitivity but lower specificity than conventional computed tomographic scanning for assessing pedicle violations. By providing real-time intraoperative imaging, 3-D fluoroscopy may enhance the safety of thoracic transpedicular instrumentation.
引用
收藏
页码:1138 / 1142
页数:5
相关论文
共 50 条
  • [1] Reliability of three-dimensional fluoroscopy for detecting pedicle screw violations in the thoracic and lumbar spine - Comments
    Benzel, EC
    McCormick, PC
    Kaiser, MG
    Le, HN
    Kim, D
    [J]. NEUROSURGERY, 2004, 54 (05) : 1142 - 1143
  • [2] The Reliability of the Ball-Tipped Probe for Detecting Pedicle Screw Tract Violations Prior to Instrumenting the Thoracic and Lumbar Spine
    Sedory, David M.
    Crawford, John J.
    Topp, Raymond F.
    [J]. SPINE, 2011, 36 (06) : E447 - E453
  • [3] Upper Lumbar Pedicle Screw Insertion Using Three-Dimensional Fluoroscopy Navigation: Assessment of Clinical Accuracy
    Sugimoto, Yoshihisa
    Ito, Yasuo
    Tomioka, Masao
    Shimokawa, Tetsuya
    Shiozaki, Yasuyuki
    Mazaki, Tetsuro
    Tanaka, Masato
    [J]. ACTA MEDICA OKAYAMA, 2010, 64 (05) : 293 - 297
  • [4] Pedicle screw fixation for traumatic fractures of the thoracic and lumbar spine
    Cheng, Li Ming
    Wang, Jian Jie
    Zeng, Zhi Li
    Zhu, Rui
    Yu, Yan
    Li, Chunbo
    Wu, Zhou Rui
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (05):
  • [5] Clinical Accuracy of Three-Dimensional Fluoroscopy (IsoC-3D)-Assisted Upper Thoracic Pedicle Screw Insertion
    Sugimoto, Yoshihisa
    Ito, Yasuo
    Tomioka, Masao
    Shimokawa, Tetsuya
    Shiozaki, Yasuyuki
    Mazaki, Tetsuro
    Tanaka, Masato
    [J]. ACTA MEDICA OKAYAMA, 2010, 64 (03) : 209 - 212
  • [6] A novel system for accurate lumbar spine pedicle screw placement based on three-dimensional computed tomography reconstruction
    Ding, Baozhi
    Zho, Tangjun
    Zhao, Jie
    [J]. JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 23 : 101 - 106
  • [7] Three-dimensional distribution of CT attenuation in the lumbar spine pedicle wall
    Irie, Tomoyo Y.
    Irie, Tohru
    Espinoza Orias, Alejandro A.
    Segami, Kazuyuki
    Iwasaki, Norimasa
    An, Howard S.
    Inoue, Nozomu
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] Three-dimensional distribution of CT attenuation in the lumbar spine pedicle wall
    Tomoyo Y. Irie
    Tohru Irie
    Alejandro A. Espinoza Orías
    Kazuyuki Segami
    Norimasa Iwasaki
    Howard S. An
    Nozomu Inoue
    [J]. Scientific Reports, 11
  • [9] Minimally invasive transmuscular pedicle screw fixation of the thoracic and lumbar spine
    Ringel, Florian
    Stoffel, Michael
    Stueer, Carsten
    Meyer, Bernhard
    [J]. NEUROSURGERY, 2006, 59 (04) : 361 - 366
  • [10] Reliability of axial landmarks for pedicle screw placement in the lower lumbar spine
    Robertson, PA
    Novotny, JE
    Grobler, LJ
    Abgai, JU
    [J]. SPINE, 1998, 23 (01) : 60 - 66