Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT

被引:24
|
作者
Cao, Qian [1 ]
Zbijewski, Wojciech [1 ]
Sisniega, Alejandro [1 ]
Yorkston, John [2 ]
Siewerdsen, Jeffrey H. [1 ,3 ]
Stayman, J. Webster [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Carestream Hlth, Rochester, NY 14608 USA
[3] Johns Hopkins Univ, Russell H Morgan Dept Radiol, Baltimore, MD 21205 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 20期
基金
美国国家卫生研究院;
关键词
CBCT; model-based reconstruction; multiresolution; bone; extremity; IMAGE QUALITY; TOMOGRAPHIC RECONSTRUCTION; BREAST CT; ALGORITHMS; REGION; SYSTEM; DESIGN; MODELS;
D O I
10.1088/0031-9155/61/20/7263
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Application of model-based iterative reconstruction (MBIR) to high resolution cone-beam CT (CBCT) is computationally challenging because of the very fine discretization (voxel size <100 mu m) of the reconstructed volume. Moreover, standard MBIR techniques require that the complete transaxial support for the acquired projections is reconstructed, thus precluding acceleration by restricting the reconstruction to a region-of-interest. To reduce the computational burden of high resolution MBIR, we propose a multiresolution penalized-weighted least squares (PWLS) algorithm, where the volume is parameterized as a union of fine and coarse voxel grids as well as selective binning of detector pixels. We introduce a penalty function designed to regularize across the boundaries between the two grids. The algorithm was evaluated in simulation studies emulating an extremity CBCT system and in a physical study on a test-bench. Artifacts arising from the mismatched discretization of the fine and coarse sub-volumes were investigated. The fine grid region was parameterized using 0.15 mm voxels and the voxel size in the coarse grid region was varied by changing a downsampling factor. No significant artifacts were found in either of the regions for downsampling factors of up to 4x. For a typical extremities CBCT volume size, this downsampling corresponds to an acceleration of the reconstruction that is more than five times faster than a brute force solution that applies fine voxel parameterization to the entire volume. For certain configurations of the coarse and fine grid regions, in particular when the boundary between the regions does not cross high attenuation gradients, downsampling factors as high as 10x can be used without introducing artifacts, yielding a similar to 50x speedup in PWLS. The proposed multiresolution algorithm significantly reduces the computational burden of high resolution iterative CBCT reconstruction and can be extended to other applications of MBIR where computationally expensive, high-fidelity forward models are applied only to a sub-region of the field-of-view.
引用
收藏
页码:7263 / 7281
页数:19
相关论文
共 50 条
  • [31] Cone-beam CT reconstruction for planar object
    Liu, Tong
    NDT & E INTERNATIONAL, 2012, 45 (01) : 9 - 15
  • [32] Cone-beam reconstruction for micro-CT
    Wang, G
    Jiang, M
    Lee, SW
    Liu, H
    Hoffman, E
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 384 - 387
  • [33] Iterative Reconstruction for Circular Cone-Beam CT with an Offset Flat-Panel Detector
    Hansis, Eberhard
    Bredno, Joerg
    Sowards-Emmerd, David
    Shao, Lingxiong
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2228 - 2231
  • [34] Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT
    Matenine, Dmitri
    Mascolo-Fortin, Julia
    Goussard, Yves
    Despres, Philippe
    MEDICAL PHYSICS, 2015, 42 (11) : 6376 - 6386
  • [35] Iterative Helical Cone-Beam CT Reconstruction Using Graphics Hardware: A Simulation Study
    Pan, Yongsheng
    Whitaker, Ross
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [36] Handling of long objects in iterative improvement of nonexact reconstruction in helical cone-beam CT
    Magnusson, Maria
    Danielsson, Per-Erik
    Sunnegardh, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 935 - 940
  • [37] Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging
    Tilley, Steven, II
    Jacobson, Matthew
    Cao, Qian
    Brehler, Michael
    Sisniega, Alejandro
    Zbijewski, Wojciech
    Stayman, J. Webster
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (04) : 988 - 999
  • [38] Planar Cone-Beam Computed Tomography for High-Resolution Industrial Application
    Liu, Tong
    FOURTH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2010, 7522
  • [39] Cone Artifacts Correction in Iterative Cone Beam CT Reconstruction
    Yan, H.
    Wang, X.
    Bai, T.
    Lu, W.
    Folkerts, M.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 526 - 526
  • [40] Clinically relevant human temporal bone measurements using novel high-resolution cone-beam CT
    Jing Zou
    Jaakko Lhelm
    Antti Arnisalo
    Ilmari Pyykk
    JournalofOtology, 2017, 12 (01) : 9 - 17