Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging

被引:25
|
作者
Tilley, Steven, II [1 ]
Jacobson, Matthew [1 ]
Cao, Qian [1 ]
Brehler, Michael [1 ]
Sisniega, Alejandro [1 ]
Zbijewski, Wojciech [1 ]
Stayman, J. Webster [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
关键词
Model-based iterative reconstruction; deconvolution; noise correlation; trabecular bone; extremities imaging; X-RAY CT; STATISTICAL RECONSTRUCTION; TRANSMISSION TOMOGRAPHY; COMPUTED-TOMOGRAPHY; SYSTEM RESPONSE; ORDERED SUBSETS; BREAST CT; BONE; ALGORITHM; COMPENSATION;
D O I
10.1109/TMI.2017.2779406
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a novel reconstruction algorithm based on a general cone-beam CT forward model, which is capable of incorporating the blur and noise correlations that are exhibited in flat-panel CBCT measurement data. Specifically, the proposed model may include scintillator blur, focal-spot blur, and noise correlations due to light spread in the scintillator. The proposed algorithm (GPL-BC) uses a Gaussian Penalized-Likelihood objective function, which incorporates models of blur and correlated noise. In a simulation study, GPL-BC was able to achieve lower bias as compared with deblurring followed by FDK as well as a model-based reconstruction method without integration of measurement blur. In the same study, GPL-BC was able to achieve better line-pair reconstructions (in terms of segmented-image accuracy) as compared with deblurring followed by FDK, a model-based method without blur, and a model-based method with blur but not noise correlations. A prototype extremities quantitative cone-beam CT test-bench was used to image a physical sample of human trabecular bone. These data were used to compare reconstructions using the proposed method and model-based methods without blur and/or correlation to a registered mu CT image of the same bone sample. The GPL-BC reconstructions resulted in more accurate trabecular bone segmentation. Multiple trabecular bone metrics, including trabecular thickness (Tb.Th.) were computed for each reconstruction approach as well as the mu CT volume. The GPL-BC reconstruction provided the most accurate Tb.Th. measurement, 0.255 mm, as compared with the mu CT derived value of 0.193 mm, followed by the GPL-B reconstruction, the GPL-I reconstruction, and then the FDK reconstruction (0.271 mm, 0.309 mm, and 0.335 mm, respectively).
引用
收藏
页码:988 / 999
页数:12
相关论文
共 50 条
  • [1] Penalized-Likelihood Reconstruction for Metal Artifact Reduction in Cone-Beam CT
    Aootaphao, Sorapong
    Pintavirooj, Chuchart
    Sotthivirat, Saowapak
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2733 - 2736
  • [2] Spatial Resolution and Noise Prediction in Flat-Panel Cone-Beam CT Penalized-likelihood Reconstruction
    Wang, W.
    Gang, G. J.
    Siewerdsen, J. H.
    Stayman, J. W.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [3] High-fidelity artifact correction for cone-beam CT imaging of the brain
    Sisniega, A.
    Zbijewski, W.
    Xu, J.
    Dang, H.
    Stayman, J. W.
    Yorkston, J.
    Aygun, N.
    Koliatsos, V.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04): : 1415 - 1439
  • [4] Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT
    Cao, Qian
    Zbijewski, Wojciech
    Sisniega, Alejandro
    Yorkston, John
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (20): : 7263 - 7281
  • [5] Cone-Beam CT for Neurosurgical Guidance: High-Fidelity Artifacts Correction for Soft-Tissue Contrast Resolution
    Wu, P.
    Sisniega, A.
    Uneri, A.
    Han, R.
    Ketcha, M.
    Jones, C. K.
    Vagdargi, P.
    Zhang, X.
    Luciano, M.
    Anderson, W. S.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [6] High-Resolution Extremity Cone-Beam CT Prototype System
    Bernstein, M.
    Karp, J.
    Li, K.
    Zbijewski, W.
    MEDICAL PHYSICS, 2018, 45 (06) : E539 - E539
  • [7] Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems
    Stayman, JW
    Fessler, JA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (03) : 269 - 284
  • [8] IMAGING CHARACTERISTICS OF A HIGH-RESOLUTION CONE BEAM COLLIMATOR
    JASZCZAK, RJ
    GREER, KL
    FLOYD, CE
    MANGLOS, SH
    COLEMAN, RE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 644 - 648
  • [9] High-fidelity and high-resolution phase mapping of granites via confocal Raman imaging
    Krishna C. Polavaram
    Nishant Garg
    Scientific Reports, 11
  • [10] High-fidelity and high-resolution phase mapping of granites via confocal Raman imaging
    Polavaram, Krishna C.
    Garg, Nishant
    SCIENTIFIC REPORTS, 2021, 11 (01)