Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging

被引:25
|
作者
Tilley, Steven, II [1 ]
Jacobson, Matthew [1 ]
Cao, Qian [1 ]
Brehler, Michael [1 ]
Sisniega, Alejandro [1 ]
Zbijewski, Wojciech [1 ]
Stayman, J. Webster [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
关键词
Model-based iterative reconstruction; deconvolution; noise correlation; trabecular bone; extremities imaging; X-RAY CT; STATISTICAL RECONSTRUCTION; TRANSMISSION TOMOGRAPHY; COMPUTED-TOMOGRAPHY; SYSTEM RESPONSE; ORDERED SUBSETS; BREAST CT; BONE; ALGORITHM; COMPENSATION;
D O I
10.1109/TMI.2017.2779406
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a novel reconstruction algorithm based on a general cone-beam CT forward model, which is capable of incorporating the blur and noise correlations that are exhibited in flat-panel CBCT measurement data. Specifically, the proposed model may include scintillator blur, focal-spot blur, and noise correlations due to light spread in the scintillator. The proposed algorithm (GPL-BC) uses a Gaussian Penalized-Likelihood objective function, which incorporates models of blur and correlated noise. In a simulation study, GPL-BC was able to achieve lower bias as compared with deblurring followed by FDK as well as a model-based reconstruction method without integration of measurement blur. In the same study, GPL-BC was able to achieve better line-pair reconstructions (in terms of segmented-image accuracy) as compared with deblurring followed by FDK, a model-based method without blur, and a model-based method with blur but not noise correlations. A prototype extremities quantitative cone-beam CT test-bench was used to image a physical sample of human trabecular bone. These data were used to compare reconstructions using the proposed method and model-based methods without blur and/or correlation to a registered mu CT image of the same bone sample. The GPL-BC reconstructions resulted in more accurate trabecular bone segmentation. Multiple trabecular bone metrics, including trabecular thickness (Tb.Th.) were computed for each reconstruction approach as well as the mu CT volume. The GPL-BC reconstruction provided the most accurate Tb.Th. measurement, 0.255 mm, as compared with the mu CT derived value of 0.193 mm, followed by the GPL-B reconstruction, the GPL-I reconstruction, and then the FDK reconstruction (0.271 mm, 0.309 mm, and 0.335 mm, respectively).
引用
收藏
页码:988 / 999
页数:12
相关论文
共 50 条
  • [21] Efficacy of high-resolution cone-beam CT in the evaluation of perforators in vertebral artery dissection
    Shimada, Kenji
    Tanaka, Michihiro
    Kadooka, Keisuke
    Hadeishi, Hiromu
    INTERVENTIONAL NEURORADIOLOGY, 2017, 23 (04) : 350 - 356
  • [22] Image-Based Motion Compensation for High-Resolution Extremities Cone-Beam CT
    Sisniega, A.
    Stayman, J. W.
    Cao, Q.
    Yorkston, J.
    Siewerdsen, J. H.
    Zbijewski, W.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [23] Width of the normal facial canal measured by high-resolution cone-beam computed tomography
    Komori, Masahiro
    Yamada, Kazuomi
    Hinohira, Yasuyuki
    Aritomo, Hiroshi
    Yanagihara, Naoaki
    ACTA OTO-LARYNGOLOGICA, 2013, 133 (11) : 1227 - 1232
  • [24] Developing Large High-Resolution Display Visualizations of High-Fidelity Terrain Data
    Chung, Haeyong
    North, Chris
    Ferris, John
    JOURNAL OF COMPUTING AND INFORMATION SCIENCE IN ENGINEERING, 2013, 13 (03)
  • [25] High-fidelity SIM reconstruction-based super-resolution quantitative FRET imaging
    Luo, Zewei
    Zang, Guodong
    Wu, Ge
    Kong, Mengting
    Zhuang, Zhengfei
    Chen, Tongsheng
    ADVANCED PHOTONICS NEXUS, 2023, 2 (05):
  • [26] Potential of 80-kV high-resolution cone-beam CT imaging combined with an optimized protocol for neurological surgery
    Kanayama, Seisaku
    Hara, Takayuki
    Hamada, Yusuke
    Matsumaru, Yuji
    NEURORADIOLOGY, 2015, 57 (02) : 155 - 162
  • [27] Potential of 80-kV high-resolution cone-beam CT imaging combined with an optimized protocol for neurological surgery
    Seisaku Kanayama
    Takayuki Hara
    Yusuke Hamada
    Yuji Matsumaru
    Neuroradiology, 2015, 57 : 155 - 162
  • [28] High-resolution reconstruction for terahertz imaging
    Xu, Li-Min
    Fan, Wen-Hui
    Liu, Jia
    APPLIED OPTICS, 2014, 53 (33) : 7891 - 7897
  • [29] Development and application of a high-fidelity and high-resolution telemetry seismic data acquisition system
    Du LiZhi
    Qiu JianHui
    Zhang Qi
    Zhang XiaoPei
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2019, 62 (10): : 3964 - 3973
  • [30] Validation of high-resolution echocardiography and magnetic resonance imaging vs. high-fidelity catheterization in experimental pulmonary hypertension
    Urboniene, Dalia
    Haber, Idith
    Fang, Yong-Hu
    Thenappan, Thenappan
    Archer, Stephen L.
    AMERICAN JOURNAL OF PHYSIOLOGY-LUNG CELLULAR AND MOLECULAR PHYSIOLOGY, 2010, 299 (03) : L401 - L412