Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging

被引:25
|
作者
Tilley, Steven, II [1 ]
Jacobson, Matthew [1 ]
Cao, Qian [1 ]
Brehler, Michael [1 ]
Sisniega, Alejandro [1 ]
Zbijewski, Wojciech [1 ]
Stayman, J. Webster [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
关键词
Model-based iterative reconstruction; deconvolution; noise correlation; trabecular bone; extremities imaging; X-RAY CT; STATISTICAL RECONSTRUCTION; TRANSMISSION TOMOGRAPHY; COMPUTED-TOMOGRAPHY; SYSTEM RESPONSE; ORDERED SUBSETS; BREAST CT; BONE; ALGORITHM; COMPENSATION;
D O I
10.1109/TMI.2017.2779406
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a novel reconstruction algorithm based on a general cone-beam CT forward model, which is capable of incorporating the blur and noise correlations that are exhibited in flat-panel CBCT measurement data. Specifically, the proposed model may include scintillator blur, focal-spot blur, and noise correlations due to light spread in the scintillator. The proposed algorithm (GPL-BC) uses a Gaussian Penalized-Likelihood objective function, which incorporates models of blur and correlated noise. In a simulation study, GPL-BC was able to achieve lower bias as compared with deblurring followed by FDK as well as a model-based reconstruction method without integration of measurement blur. In the same study, GPL-BC was able to achieve better line-pair reconstructions (in terms of segmented-image accuracy) as compared with deblurring followed by FDK, a model-based method without blur, and a model-based method with blur but not noise correlations. A prototype extremities quantitative cone-beam CT test-bench was used to image a physical sample of human trabecular bone. These data were used to compare reconstructions using the proposed method and model-based methods without blur and/or correlation to a registered mu CT image of the same bone sample. The GPL-BC reconstructions resulted in more accurate trabecular bone segmentation. Multiple trabecular bone metrics, including trabecular thickness (Tb.Th.) were computed for each reconstruction approach as well as the mu CT volume. The GPL-BC reconstruction provided the most accurate Tb.Th. measurement, 0.255 mm, as compared with the mu CT derived value of 0.193 mm, followed by the GPL-B reconstruction, the GPL-I reconstruction, and then the FDK reconstruction (0.271 mm, 0.309 mm, and 0.335 mm, respectively).
引用
收藏
页码:988 / 999
页数:12
相关论文
共 50 条
  • [31] High-speed cone-beam reconstruction: an embedded systems approach
    Goddard, I
    Trepanier, M
    MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 : 483 - 491
  • [32] Quantitative Evaluation of Bone Microstructure using High-Resolution Extremity Cone-Beam CT with a CMOS Detector
    Subramanian, S.
    Brehler, M.
    Cao, Q.
    Gonzalez, F. J. Quevedo
    Breighner, R. E.
    Canino, J. A.
    Wright, T.
    Yorkston, J.
    Siewerdsen, J. H.
    Zbijewski, W.
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [33] Clinically relevant human temporal bone measurements using novel high-resolution cone-beam CT
    Jing Zou
    Jaakko Lhelm
    Antti Arnisalo
    Ilmari Pyykk
    Journal of Otology, 2017, 12 (01) : 9 - 17
  • [34] High-resolution cone-beam computed tomography: a potential tool to improve atraumatic electrode design and position
    Cushing, Sharon L.
    Daly, Michael J.
    Treaba, Claudiu G.
    Chan, Harley
    Irish, Jonathan C.
    Blaser, Susan
    Gordon, Karen A.
    Papsin, Blake C.
    ACTA OTO-LARYNGOLOGICA, 2012, 132 (04) : 361 - 368
  • [35] HIGH-RESOLUTION AND HIGH-FIDELITY X-RAY MASK STRUCTURE EMPLOYING EMBEDDED ABSORBERS
    CHOU, SY
    MALUF, NI
    PEASE, RFW
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1988, 6 (06): : 2202 - 2206
  • [36] High-Fidelity High-Resolution Regional Seismic Risk and Resilience Assessment of Large Building Inventories
    Dahal, Laxman
    Burton, Henry
    Zhong, Kuanshi
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2025,
  • [37] Towards high-fidelity high-resolution modeling of a BWR fuel assembly by CASMO-5
    Cherezov, Alexey
    Vasiliev, Alexander
    Ferroukhi, Hakim
    ANNALS OF NUCLEAR ENERGY, 2025, 213
  • [38] High Quality and Low Dose Cone-beam CT Imaging with Anisotropic Regularized FDK Reconstruction Algorithm
    Lee, H.
    Lee, R.
    Suh, T.
    Jeong, W.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S70 - S70
  • [39] Detection of Incomplete Root Fractures in Endodontically Treated Teeth Using Different High-resolution Cone-beam Computed Tomographic Imaging Protocols
    Wanderley, Victor Aquino
    Neves, Frederico Sampaio
    Chagas Nascimento, Monikelly Carmo
    de Melo Monteiro, Gabriela Queiroz
    Lobo, Natalia Siqueira
    Oliveira, Matheus Lima
    Sobrinho Nascimento Neto, Joao Batista
    Araujo, Luciane Farias
    JOURNAL OF ENDODONTICS, 2017, 43 (10) : 1720 - 1724
  • [40] High-resolution images of cone beam collimated CT scans
    Shechter, G
    Altman, A
    Koehler, T
    Proksa, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2973 - 2977