A Four Terminal Pair Digitally Assisted Impedance Bridge at TUBITAK UME

被引:0
|
作者
Turhan, Enis [1 ]
Giilmez, Giilay [1 ]
Erkan, Omer [1 ]
Hayirli, Cem [1 ]
机构
[1] TUBITAK Ulusal Metrol Enstitusu UME, PK 54, TR-41470 Gebze, Turkey
关键词
Impedance bridge; automation; bridge circuits; impedance measurements; impedance standard; precision measurements;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Capacitance and AC resistance comparisons at audio frequencies are being performed by using a four-terminal pair transformer- based coaxial AC bridge at TUBITAK UME. A four-terminal pair digitally assisted (DA) coaxial AC bridge has been developed in order to reduce the complexity of coaxial transformer AC bridges. This paper describes realization of fourterminal pair DA coaxial AC bridge using commercial DAQ modules and performance test measurements by using the transformer-based bridge. According to preliminary results, the bridge can be balanced automatically in less than 5 minutes. R- R and C-C comparisons at 1 kHz and 10 k Omega magnitude level give ratio errors of a few 10(-6). Further improvements for ratio errors and bridge balancing time will be performed.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] A Digital Five-Terminal Impedance Bridge
    Ihlenfeld, Waldemar G. Kurten
    de Barros e Vasconcellos, Renata T.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (06) : 1546 - 1552
  • [32] Self-Compensating Networks for Four-Terminal-Pair Impedance Definition in Current Comparator Bridges
    Callegaro, Luca
    D'Elia, Vincenzo
    Kucera, Jan
    Ortolano, Massimo
    Pourdanesh, Faranak
    Trinchera, Bruno
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (05) : 1149 - 1155
  • [33] Self-compensating networks for four terminal-pair impedance definition in current comparator bridges
    CaRegan, Luca
    D'Llia, Vincenzo
    Pourdanesh, Faranak
    Trinchera, Bruno
    Kucera, Jan
    Ortolan, Massimo
    [J]. 2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 1658 - 1661
  • [34] New impedance bridge at LNE for the two terminal-pair AC resistor calibration up to 20 kHz
    Ouameur, Mohamed
    Vasconcellos, Renata
    Agazar, Mohamed
    Thevenot, Olivier
    Patois, Emmanuel
    [J]. METROLOGIA, 2022, 59 (05)
  • [35] Calibration of four-terminal-pair resistor
    Dai Dongxue
    Ruan Yongshun
    Wang Xiaochao
    [J]. 2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 332 - 333
  • [36] Evaluation of air dielectric four-terminal-pair capacitance standards using resonance frequency of impedance elements
    Satish
    Kumar, Sachin
    Babita
    John, Thomas
    Saxena, A. K.
    [J]. MEASUREMENT, 2017, 100 : 176 - 182
  • [37] A Four-Terminal Coaxial-Pair Maxwell-Wein Bridge for the Measurement of Self-Inductance
    Cote, Marcel
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) : 962 - 966
  • [38] A digitally assisted IVD calibration bridge using a programmable digital detector
    Jain, Priyanka
    Sathish
    Kumar, Sachin
    Singh, Nidhi
    John, Thomas
    Biswas, J. C.
    [J]. MEASUREMENT, 2023, 206
  • [39] A complementary pair of four-terminal silicon synapses
    Diorio, C
    Hasler, P
    Minch, BA
    Mead, C
    [J]. ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 1997, 13 (1-2) : 153 - 166
  • [40] Four-terminal-pair impedances and scattering parameters
    Callegaro, L
    Durbiano, F