Evaluation of air dielectric four-terminal-pair capacitance standards using resonance frequency of impedance elements

被引:8
|
作者
Satish [1 ]
Kumar, Sachin [1 ]
Babita [1 ]
John, Thomas [1 ]
Saxena, A. K. [1 ]
机构
[1] CSIR, Natl Phys Lab, LF HF Impedance & DC Metrol, New Delhi, India
关键词
Four-terminal-pair; Capacitance standards; Resonance frequency; Impedance; Uncertainty;
D O I
10.1016/j.measurement.2016.12.052
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new method is proposed for the evaluation of air dielectric four-terminal-pair capacitance standards of nominal values 100 pF and 1000 pF using resonance frequency of impedance elements. It involves the determination of residual inductive and capacitive parameters of simple electrical-circuit-model of capacitance standards and thereafter computation of effective capacitance as a function of frequency up-to 10 MHz. The reference capacitance and residual capacitive parameters are measured using capacitance bridge and residual inductive parameters are estimated using measured resonance frequencies. The reported work will be helpful in the establishment of calibration services for capacitances up-to 10 MHz at CSIR-National Physical Laboratory. The uncertainty in measurement of effective capacitance is evaluated at k = 2 as per guide to the expression of uncertainty in measurement. The uncertainty budgets for 100 pF and 1000 pF capacitance standards at 1 MHz and 10 MHz respectively are also provided to analyze the sources of uncertainty contributing to the final uncertainty in measurement. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:176 / 182
页数:7
相关论文
共 29 条
  • [1] Resonance frequency of four-terminal-pair air-dielectric capacitance standards and closing the metrological impedance triangle
    Awan, SA
    Callegaro, L
    Kibble, BP
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (05) : 969 - 972
  • [2] Effect of humidity on the calibration of the four-terminal-pair air-dielectric capacitance standards
    Lee, Hyung-Kew
    Kim, Dan Bee
    Kim, Wan-Seop
    [J]. MEASUREMENT, 2016, 86 : 196 - 201
  • [3] Evaluation of four-terminal-pair capacitance standards using electrical equivalent circuit model
    Satish
    Babita
    Khurana, Bharat
    Kumar, Sachin
    Saxena, A. K.
    [J]. MEASUREMENT, 2015, 73 : 121 - 126
  • [4] Calibration method for four-terminal-pair capacitance standards: Progress report
    Aoki, T
    Suzuki, K
    Yokoi, K
    [J]. 1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 36 - 37
  • [5] Realization of Four-Terminal-Pair Capacitors as Reference Standards of Impedance at High Frequency Using Impedance-Matrix Method
    Singh, Satish
    Kumar, Sachin
    Babita
    John, Thomas
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (08) : 2129 - 2135
  • [6] Measurement Automation to Implement Evaluation Procedure of Four-Terminal-Pair Capacitance Standards Using S-Parameters
    Satish
    Babita
    Khurana, Bharat
    John, Thomas
    [J]. MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2017, 32 (03): : 175 - 181
  • [7] Measurement Automation to Implement Evaluation Procedure of Four-Terminal-Pair Capacitance Standards Using S-Parameters
    Bharat Satish
    Thomas Babita
    [J]. MAPAN, 2017, 32 : 175 - 181
  • [8] Four-terminal-pair capacitance characterization at frequencies up to 30 MHz using resonance frequencies
    Ozkan, Turgay
    Gulmez, Gulay
    Turhan, Enis
    Gulmez, Yakup
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (11) : 3496 - 3500
  • [9] Uncertainty Evaluation using the Monte-Carlo Method for the Calibration of Four Terminal Pair Air Capacitance Standards
    Lee, Hyung-Kew
    Kim, Dan Bee
    Kim, Wan-Seop
    [J]. 2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [10] A design for four-terminal-pair resistor with calculable frequency dependence
    Tong Yazhen
    Huang Xiaoding
    [J]. PROCEEDINGS OF 2015 IEEE 12TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL. 1, 2015, : 411 - 415