Repeatability and reproducibility of anterior ocular biometric measurements with 2-dimensional and 3-dimensional optical coherence tomography

被引:44
|
作者
Fukuda, Shinichi [1 ,2 ]
Kawana, Keisuke [1 ,2 ]
Yasuno, Yoshiaki [2 ,3 ]
Oshika, Tetsuro [1 ,2 ]
机构
[1] Univ Tsukuba, Dept Ophthalmol, Inst Clin Med, Tsukuba, Ibaraki 3058575, Japan
[2] Univ Tsukuba, Computat Opt & Ophthalmol Grp, Tsukuba, Ibaraki 3058575, Japan
[3] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 3058575, Japan
来源
基金
日本学术振兴会;
关键词
HIGH-SPEED; ULTRASOUND BIOMICROSCOPY; CORNEAL THICKNESS; SEGMENT;
D O I
10.1016/j.jcrs.2010.05.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE To evaluate the repeatability and reproducibility of central corneal thickness (CCT), anterior chamber depth (ACD), and anterior chamber width (ACW) measurements using 3-dimensional (3-D) corneal and anterior segment optical coherence tomography (CAS-OCT) and 2-dimensional (2-D) anterior segment OCT (AS-OCT) SETTING Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan DESIGN Nonrandomized clinical trial METHODS The CCT, ACD, and ACW were measured in normal eyes using a prototype 3-D swept-source CAS-OCT device and a 2-D time-domain AS-OCT device (Visante) The coefficient of repeatability and reproducibility and the intraclass correlation coefficient (ICC) were calculated to evaluate the repeatability and reproducibility of the measurements RESULTS Eighty-five eyes (85 subjects) were evaluated The mean CCT measurement was 557 5 mu m +/- 40 5 (SD) with CAS-OCT and 556 4 +/- 39 4 mu m with AS-OCT, the mean ACD measurement, 3 13 +/- 0 40 mm and 3 16 +/- 0 39 mm, respectively, and the mean ACW, 11 80 + 0 47 mm and 11 79 + 0 49 mm, respectively There was no statistically significant difference in CCT or AC,W measurements between the 2 devices (P> 05, Wilcoxon signed rank test) Although the ACD measurements were significantly different (P< 0001), the difference was small (0 03 mm) Significant linear correlations were found between the measurements of the 2 devices (P< 0(101) The ICC was greater than 0 99 for CAS-OCT and greater than 0 96 for AS-OCT CONCLUSION Corneal and anterior segment OCT and AS-OCT provided comparable and well-correlated anterior ocular biometric measurements with sufficient repeatability and reproducibility
引用
收藏
页码:1867 / 1873
页数:7
相关论文
共 50 条
  • [41] Repeatability and reproducibility of vessel density measurements on optical coherence tomography angiography in diabetic retinopathy
    Emily S. Levine
    Malvika Arya
    Juhi Chaudhari
    Eugenia Custo Greig
    A. Yasin Alibhai
    Caroline R. Baumal
    Andre J. Witkin
    Jay S. Duker
    Nadia K. Waheed
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1687 - 1695
  • [42] 2-DIMENSIONAL AND 3-DIMENSIONAL BOUNDARY DETECTION
    LIU, HK
    COMPUTER GRAPHICS AND IMAGE PROCESSING, 1977, 6 (02): : 123 - 134
  • [43] ON 2-DIMENSIONAL AND 3-DIMENSIONAL EXPANSION FLOWS
    BALOCH, A
    TOWNSEND, P
    WEBSTER, MF
    COMPUTERS & FLUIDS, 1995, 24 (08) : 863 - 882
  • [44] 3-DIMENSIONAL SCATTERING BY 2-DIMENSIONAL TOPOGRAPHIES
    PEDERSEN, HA
    SANCHEZSESMA, FJ
    CAMPILLO, M
    BULLETIN OF THE SEISMOLOGICAL SOCIETY OF AMERICA, 1994, 84 (04) : 1169 - 1183
  • [45] 2-DIMENSIONAL MEASURE IN 3-DIMENSIONAL SPACE
    TORALBAL.LV
    NOTICES OF THE AMERICAN MATHEMATICAL SOCIETY, 1973, 20 (01): : A103 - A103
  • [46] 2-DIMENSIONAL AND 3-DIMENSIONAL BGK WAVES
    KATO, K
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1976, 41 (03) : 1050 - 1053
  • [47] 2-DIMENSIONAL AND 3-DIMENSIONAL FLUID TRANSIENTS
    FABIC, S
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (01): : 360 - &
  • [48] 2-DIMENSIONAL AND 3-DIMENSIONAL ENVELOPE SOLITONS
    KAW, PK
    NISHIKAWA, K
    YOSHIDA, Y
    HASEGAWA, A
    PHYSICAL REVIEW LETTERS, 1975, 35 (02) : 88 - 91
  • [49] NONSEPARABLE 2-DIMENSIONAL AND 3-DIMENSIONAL WAVELETS
    KOVACEVIC, J
    VETTERLI, M
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1995, 43 (05) : 1269 - 1273
  • [50] HOLOGRAPHY IN 2-DIMENSIONAL AND 3-DIMENSIONAL MEDIA
    DENISYUK, YN
    SUKHANOV, VI
    SOVIET PHYSICS USPEKHI-USSR, 1972, 14 (06): : 805 - &