Repeatability and reproducibility of anterior ocular biometric measurements with 2-dimensional and 3-dimensional optical coherence tomography

被引:44
|
作者
Fukuda, Shinichi [1 ,2 ]
Kawana, Keisuke [1 ,2 ]
Yasuno, Yoshiaki [2 ,3 ]
Oshika, Tetsuro [1 ,2 ]
机构
[1] Univ Tsukuba, Dept Ophthalmol, Inst Clin Med, Tsukuba, Ibaraki 3058575, Japan
[2] Univ Tsukuba, Computat Opt & Ophthalmol Grp, Tsukuba, Ibaraki 3058575, Japan
[3] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 3058575, Japan
来源
基金
日本学术振兴会;
关键词
HIGH-SPEED; ULTRASOUND BIOMICROSCOPY; CORNEAL THICKNESS; SEGMENT;
D O I
10.1016/j.jcrs.2010.05.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE To evaluate the repeatability and reproducibility of central corneal thickness (CCT), anterior chamber depth (ACD), and anterior chamber width (ACW) measurements using 3-dimensional (3-D) corneal and anterior segment optical coherence tomography (CAS-OCT) and 2-dimensional (2-D) anterior segment OCT (AS-OCT) SETTING Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan DESIGN Nonrandomized clinical trial METHODS The CCT, ACD, and ACW were measured in normal eyes using a prototype 3-D swept-source CAS-OCT device and a 2-D time-domain AS-OCT device (Visante) The coefficient of repeatability and reproducibility and the intraclass correlation coefficient (ICC) were calculated to evaluate the repeatability and reproducibility of the measurements RESULTS Eighty-five eyes (85 subjects) were evaluated The mean CCT measurement was 557 5 mu m +/- 40 5 (SD) with CAS-OCT and 556 4 +/- 39 4 mu m with AS-OCT, the mean ACD measurement, 3 13 +/- 0 40 mm and 3 16 +/- 0 39 mm, respectively, and the mean ACW, 11 80 + 0 47 mm and 11 79 + 0 49 mm, respectively There was no statistically significant difference in CCT or AC,W measurements between the 2 devices (P> 05, Wilcoxon signed rank test) Although the ACD measurements were significantly different (P< 0001), the difference was small (0 03 mm) Significant linear correlations were found between the measurements of the 2 devices (P< 0(101) The ICC was greater than 0 99 for CAS-OCT and greater than 0 96 for AS-OCT CONCLUSION Corneal and anterior segment OCT and AS-OCT provided comparable and well-correlated anterior ocular biometric measurements with sufficient repeatability and reproducibility
引用
收藏
页码:1867 / 1873
页数:7
相关论文
共 50 条
  • [21] 2-DIMENSIONAL AND 3-DIMENSIONAL INSTANTONS
    LOHE, MA
    PHYSICS LETTERS B, 1977, 70 (03) : 325 - 328
  • [22] Effect of Facial Asymmetry on 2-Dimensional and 3-Dimensional Cephalometric Measurements
    Gateno, Jaime
    Xia, James J.
    Teichgraeber, John F.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (03) : 655 - 662
  • [23] 2-Dimensional and 3-Dimensional Navigation
    Asha, P.
    Rajakumari, Kavitha Esther
    Abhilash, R.
    2017 IEEE INTERNATIONAL CONFERENCE ON POWER, CONTROL, SIGNALS AND INSTRUMENTATION ENGINEERING (ICPCSI), 2017, : 2036 - 2040
  • [24] Enhanced Diagnostic Capability for Glaucoma of 3-Dimensional Versus 2-Dimensional Neuroretinal Rim Parameters Using Spectral Domain Optical Coherence Tomography
    Fan, Kenneth C.
    Tsikata, Edem
    Khoueir, Ziad
    Simavli, Huseyin
    Guo, Rong
    de Luna, Regina A.
    Pandit, Sumir
    Que, Christian J.
    de Boer, Johannes F.
    Chen, Teresa C.
    JOURNAL OF GLAUCOMA, 2017, 26 (05) : 450 - 458
  • [25] Repeatability and reproducibility of pachymetric mapping with visante anterior segment-optical coherence tomography
    Mohamed, Shaheeda
    Lee, Gary K. Y.
    Rao, Srinivas K.
    Wong, Amy L.
    Cheng, Arthur C. K.
    Li, Emmy Y. M.
    Chi, Stanley C. C.
    Lam, Dennis S. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (12) : 5499 - 5504
  • [26] Corneal topographic analysis in patients with keratoconus using 3-dimensional anterior segment optical coherence tomography
    Nakagawa, Tomoya
    Maeda, Naoyuki
    Higashiura, Ritsuko
    Hori, Yuichi
    Inoue, Tomoyuki
    Nishida, Kohji
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (10): : 1871 - 1878
  • [27] Filtering Blebs Using 3-Dimensional Anterior-Segment Optical Coherence Tomography A Prospective Investigation
    Kojima, Sachi
    Inoue, Toshihiro
    Nakashima, Kei-Ichi
    Fukushima, Ayako
    Tanihara, Hidenobu
    JAMA OPHTHALMOLOGY, 2015, 133 (02) : 148 - 156
  • [28] Corneal Topographic Analysis by 3-Dimensional Anterior Segment Optical Coherence Tomography after Endothelial Keratoplasty
    Higashiura, Ritsuko
    Maeda, Naoyuki
    Nakagawa, Tomoya
    Fuchihata, Mutsumi
    Koh, Shizuka
    Hori, Yuichi
    Inoue, Tomoyuki
    Nishida, Kohji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) : 3286 - 3295
  • [29] Repeatability of ocular surface vessel density measurements with optical coherence tomography angiography
    Sijie Cai
    Fengping Zhao
    Chixin Du
    BMC Ophthalmology, 19
  • [30] ANALYSIS OF REPRODUCIBILITY OF 2-DIMENSIONAL ECHOCARDIOGRAPHIC MEASUREMENTS
    HENG, MK
    WYATT, HL
    MEERBAUM, S
    WOYTHALER, J
    HESTENES, J
    DAVIDSON, R
    CORDAY, E