Repeatability and reproducibility of anterior ocular biometric measurements with 2-dimensional and 3-dimensional optical coherence tomography

被引:44
|
作者
Fukuda, Shinichi [1 ,2 ]
Kawana, Keisuke [1 ,2 ]
Yasuno, Yoshiaki [2 ,3 ]
Oshika, Tetsuro [1 ,2 ]
机构
[1] Univ Tsukuba, Dept Ophthalmol, Inst Clin Med, Tsukuba, Ibaraki 3058575, Japan
[2] Univ Tsukuba, Computat Opt & Ophthalmol Grp, Tsukuba, Ibaraki 3058575, Japan
[3] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 3058575, Japan
来源
基金
日本学术振兴会;
关键词
HIGH-SPEED; ULTRASOUND BIOMICROSCOPY; CORNEAL THICKNESS; SEGMENT;
D O I
10.1016/j.jcrs.2010.05.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE To evaluate the repeatability and reproducibility of central corneal thickness (CCT), anterior chamber depth (ACD), and anterior chamber width (ACW) measurements using 3-dimensional (3-D) corneal and anterior segment optical coherence tomography (CAS-OCT) and 2-dimensional (2-D) anterior segment OCT (AS-OCT) SETTING Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan DESIGN Nonrandomized clinical trial METHODS The CCT, ACD, and ACW were measured in normal eyes using a prototype 3-D swept-source CAS-OCT device and a 2-D time-domain AS-OCT device (Visante) The coefficient of repeatability and reproducibility and the intraclass correlation coefficient (ICC) were calculated to evaluate the repeatability and reproducibility of the measurements RESULTS Eighty-five eyes (85 subjects) were evaluated The mean CCT measurement was 557 5 mu m +/- 40 5 (SD) with CAS-OCT and 556 4 +/- 39 4 mu m with AS-OCT, the mean ACD measurement, 3 13 +/- 0 40 mm and 3 16 +/- 0 39 mm, respectively, and the mean ACW, 11 80 + 0 47 mm and 11 79 + 0 49 mm, respectively There was no statistically significant difference in CCT or AC,W measurements between the 2 devices (P> 05, Wilcoxon signed rank test) Although the ACD measurements were significantly different (P< 0001), the difference was small (0 03 mm) Significant linear correlations were found between the measurements of the 2 devices (P< 0(101) The ICC was greater than 0 99 for CAS-OCT and greater than 0 96 for AS-OCT CONCLUSION Corneal and anterior segment OCT and AS-OCT provided comparable and well-correlated anterior ocular biometric measurements with sufficient repeatability and reproducibility
引用
收藏
页码:1867 / 1873
页数:7
相关论文
共 50 条
  • [31] Repeatability of ocular surface vessel density measurements with optical coherence tomography angiography
    Cai, Sijie
    Zhao, Fengping
    Du, Chixin
    BMC OPHTHALMOLOGY, 2019, 19 (01)
  • [32] Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power
    Lei, Chak Seng
    Lin, Xuanqiao
    Ning, Rui
    Yu, Jinjin
    Huang, Xiaomin
    Li, Kexin
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (06) : 3263 - 3279
  • [33] Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power
    Chak Seng Lei
    Xuanqiao Lin
    Rui Ning
    Jinjin Yu
    Xiaomin Huang
    Kexin Li
    Yiran Wang
    Giacomo Savini
    Domenico Schiano-Lomoriello
    Xingtao Zhou
    Jinhai Huang
    Ophthalmology and Therapy, 2023, 12 : 3263 - 3279
  • [34] Translation of 2-Dimensional Wrist Radiographic Measurements to 3-Dimensional CT Scans
    Wollstein, Ronit
    Kramer, Aviv
    Babb, James
    Petchprapa, Catherine
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2020, 25 (03): : 315 - 319
  • [35] Successful double-layer metal stents rotational ablation under 2-dimensional and 3-dimensional optical coherence tomography guidance: a case report
    Tong Yaliang
    Liu Guohui
    Zhang Cheng
    Du Beibei
    Zhao Yanan
    He Yuquan
    Yang Ping
    BMC Cardiovascular Disorders, 21
  • [36] Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography
    Bruce, Alison
    Pacey, Ian E.
    Dharni, Poonam
    Scally, Andy J.
    Barrett, Brendan T.
    OPEN OPHTHALMOLOGY JOURNAL, 2009, 3 : 10 - 14
  • [37] Successful double-layer metal stents rotational ablation under 2-dimensional and 3-dimensional optical coherence tomography guidance: a case report
    Tong, Yaliang
    Liu, Guohui
    Zhang, Cheng
    Du, Beibei
    Zhao, Yanan
    He, Yuquan
    Yang, Ping
    BMC CARDIOVASCULAR DISORDERS, 2021, 21 (01)
  • [38] Repeatability and reproducibility of vessel density measurements on optical coherence tomography angiography in diabetic retinopathy
    Levine, Emily S.
    Arya, Malvika
    Chaudhari, Juhi
    Greig, Eugenia Custo
    Alibhai, A. Yasin
    Baumal, Caroline R.
    Witkin, Andre J.
    Duker, Jay S.
    Waheed, Nadia K.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (08) : 1687 - 1695
  • [39] Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography
    Radhakrishnan, Sunita
    See, Jovina
    Smith, Scott D.
    Nolan, Winifred P.
    Ce, Zheng
    Friedman, David S.
    Huang, David
    Li, Yan
    Aung, Tin
    Chew, Paul T. K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (08) : 3683 - 3688
  • [40] Repeatability and Reproducibility of Slit Lamp, Optical Coherence Tomography, and Scheimpflug Measurements of Corneal Scars
    Das, Manoranjan
    Menda, Shivali A.
    Panigrahi, Arun K.
    Prajna, N. Venkatesh
    Yen, Michael
    Tsang, Betty
    Kumar, Alisha
    Rose-Nussbaumer, Jennifer
    Acharya, Nisha R.
    McCulloch, Charles E.
    Lietman, Thomas M.
    McLeod, Stephen D.
    Keenan, Jeremy D.
    OPHTHALMIC EPIDEMIOLOGY, 2019, 26 (04) : 251 - 256