Correlation of electron beam parameters with measured dose ratios in clinical photon beams

被引:0
|
作者
Deng, J [1 ]
Chen, Z [1 ]
Song, H [1 ]
Nath, R [1 ]
机构
[1] Yale Univ, Sch Med, New Haven, CT USA
关键词
D O I
10.1118/1.1997996
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work is to find a direct correlation between measured depth dose ratios and off axis ratios and two beam parameters for Monte Carlo simulations (i.e., the incident beam energy and radius) in clinical megavoltage photon beams in order to facilitate Monte Carlo applications in radiotherapy treatment planning. Method and Materials: The BEAM code was used to simulate the 6 MV photon beams from a Varian 2100C. A series of Monte Carlo simulations of Varian 2100C treatment head were performed for the incident beam energies from 5.1 MeV to 6.9 MeV and the beam radii from 0.03 cm to 0.12 cm. The calculated phase space files were then used for dose calculations in water. The depth dose ratio (DDR) defined as ratio of central axis depth dose at 20 cm to that at 10 cm and the off axis ratio (OAR) defined as ratio of dose at 10 cm in depth and 15 cm off axis to that at 10 cm on central axis as a function of incident electron beam energy and beam radius were studied. Results: For a fixed beam radius, the DDRs and OARs were linearly proportional to the incident beam energy for all the beam radii, with DDR = 0.5746 + 0.0072Ein and OAR = 1.4864 − 0.0824Ein, respectively. However, for a fixed incident beam energy, both DDRs and OARs were found to be virtually independent of incident beam radius, which is inconsistent with previously reported 18 MV photon beam in‐air results (Med. Phys. 29, 379, 2002). Conclusion: The OARs are more sensitive than the DDRs to the incident beam energy. However, both ratios are essentially independent of incident beam radius. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2011 / 2012
页数:2
相关论文
共 50 条
  • [1] Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams
    Tzedakis, A
    Damilakis, JE
    Mazonakis, M
    Stratakis, J
    Varveris, H
    Gourtsoyiannis, N
    MEDICAL PHYSICS, 2004, 31 (04) : 907 - 913
  • [2] INVESTIGATION OF BUILDUP DOSE FROM ELECTRON CONTAMINATION OF CLINICAL PHOTON BEAMS
    PETTI, PL
    GOODMAN, MS
    GABRIEL, TA
    MOHAN, R
    MEDICAL PHYSICS, 1983, 10 (01) : 18 - 24
  • [3] INVESTIGATION OF BUILDUP DOSE FROM ELECTRON CONTAMINATION OF CLINICAL PHOTON BEAMS
    PETTI, PL
    GOODMAN, MS
    GABRIEL, TA
    MOHAN, R
    MEDICAL PHYSICS, 1982, 9 (04) : 631 - 632
  • [4] Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation
    Yang, J
    Li, JS
    Qin, L
    Xiong, W
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2657 - 2673
  • [5] Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm
    Bloch, P
    Altschuler, MD
    Bjärngard, BE
    Kassaee, A
    McDonough, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01): : 171 - 183
  • [6] Quality assurance of measured depth dose for megavoltage photon beams
    Thompson, AV
    Zhu, TC
    Bjärngard, BE
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 3108 - 3111
  • [7] SURFACE DOSE MEASUREMENTS IN CLINICAL PHOTON BEAMS
    NILSSON, B
    SORCINI, B
    ACTA ONCOLOGICA, 1989, 28 (04) : 537 - 542
  • [8] Extraction of the photon spectra from measured beam parameters
    Bloch, P
    McDonough, J
    MEDICAL PHYSICS, 1998, 25 (05) : 752 - 757
  • [9] Extraction of the photon spectra from measured beam parameters
    University of Pennsylvania, Department of Radiation Oncology, Philadelphia, PA 19104-4283, United States
    Med. Phys., 5 (752-757):
  • [10] Effect of scanning parameters on dose-response of radiochromic films irradiated with photon and electron beams
    Tagiling, Nashrulhaq
    Ab Rashid, Raizulnasuha
    Azhan, Siti Nur Amirah
    Dollah, Norhayati
    Geso, Moshi
    Rahman, Wan Nordiana
    HELIYON, 2018, 4 (10):