Correlation of electron beam parameters with measured dose ratios in clinical photon beams

被引:0
|
作者
Deng, J [1 ]
Chen, Z [1 ]
Song, H [1 ]
Nath, R [1 ]
机构
[1] Yale Univ, Sch Med, New Haven, CT USA
关键词
D O I
10.1118/1.1997996
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work is to find a direct correlation between measured depth dose ratios and off axis ratios and two beam parameters for Monte Carlo simulations (i.e., the incident beam energy and radius) in clinical megavoltage photon beams in order to facilitate Monte Carlo applications in radiotherapy treatment planning. Method and Materials: The BEAM code was used to simulate the 6 MV photon beams from a Varian 2100C. A series of Monte Carlo simulations of Varian 2100C treatment head were performed for the incident beam energies from 5.1 MeV to 6.9 MeV and the beam radii from 0.03 cm to 0.12 cm. The calculated phase space files were then used for dose calculations in water. The depth dose ratio (DDR) defined as ratio of central axis depth dose at 20 cm to that at 10 cm and the off axis ratio (OAR) defined as ratio of dose at 10 cm in depth and 15 cm off axis to that at 10 cm on central axis as a function of incident electron beam energy and beam radius were studied. Results: For a fixed beam radius, the DDRs and OARs were linearly proportional to the incident beam energy for all the beam radii, with DDR = 0.5746 + 0.0072Ein and OAR = 1.4864 − 0.0824Ein, respectively. However, for a fixed incident beam energy, both DDRs and OARs were found to be virtually independent of incident beam radius, which is inconsistent with previously reported 18 MV photon beam in‐air results (Med. Phys. 29, 379, 2002). Conclusion: The OARs are more sensitive than the DDRs to the incident beam energy. However, both ratios are essentially independent of incident beam radius. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2011 / 2012
页数:2
相关论文
共 50 条
  • [31] Technical Note: On the impact of the incident electron beam energy on the primary dose component of flattening filter free photon beams
    Kuess, Peter
    Georg, Dietmar
    Palmans, Hugo
    Lechner, Wolfgang
    MEDICAL PHYSICS, 2016, 43 (08) : 4507 - 4513
  • [32] Photon-beam subsource sensitivity to the initial electron-beam parameters
    Fix, MK
    Keall, PJ
    Siebers, JV
    MEDICAL PHYSICS, 2005, 32 (04) : 1164 - 1175
  • [33] The Influence of Oblique Incidence Electron Beams to Beam Specification Parameters
    Supriyanto
    Soejoko, Djarwani S.
    Adi, Rachmat W.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1948 - +
  • [34] Equilibrium electron beam parameters of the High Energy Photon Source
    Xu, Haisheng
    Meng, Cai
    Peng, Yuemei
    Tian, Saike
    Wang, Na
    Cui, Xiaohao
    Du, Chongchong
    Duan, Zhe
    Guo, Yuanyuan
    He, Ping
    Huang, Xiyang
    Ji, Daheng
    Ji, Hongfei
    Jiao, Yi
    Li, Jingyi
    Li, Nan
    Li, Xiaoyu
    Lu, Xiaohan
    Liang, Pengfei
    Pan, Weimin
    Qu, Huamin
    Wang, Bin
    Wang, Jiuqing
    Wei, Yuanyuan
    Wan, Jinyu
    Xu, Gang
    Yan, Fang
    Yu, Chenghui
    Yue, Sen
    Zhang, Xiang
    Zhao, Yaliang
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2023, 7 (02) : 279 - 287
  • [35] Determination of scatter factor parameters and electron disequilibrium for monoenergetic photon beams
    McDonough, J
    Bloch, P
    Bjärngard, BE
    MEDICAL PHYSICS, 1999, 26 (02) : 200 - 205
  • [36] VARIATION OF CROSS BEAM DOSE PROFILE DUE TO THE PRESENCE OF INHOMOGENEITY IN PHOTON BEAMS
    VANDEGEIJN, J
    POCHENG, C
    MEDICAL PHYSICS, 1980, 7 (04) : 417 - 418
  • [37] Equilibrium electron beam parameters of the High Energy Photon Source
    Haisheng Xu
    Cai Meng
    Yuemei Peng
    Saike Tian
    Na Wang
    Xiaohao Cui
    Chongchong Du
    Zhe Duan
    Yuanyuan Guo
    Ping He
    Xiyang Huang
    Daheng Ji
    Hongfei Ji
    Yi Jiao
    Jingyi Li
    Nan Li
    Xiaoyu Li
    Xiaohan Lu
    Pengfei Liang
    Weimin Pan
    Huamin Qu
    Bin Wang
    Jiuqing Wang
    Yuanyuan Wei
    Jinyu Wan
    Gang Xu
    Fang Yan
    Chenghui Yu
    Sen Yue
    Xiang Zhang
    Yaliang Zhao
    Radiation Detection Technology and Methods, 2023, 7 : 279 - 287
  • [38] DIMENSIONLESS PARAMETERS FOR CORRELATION OF ELECTRON BEAM WELDING VARIABLES
    LUBIN, BT
    WELDING JOURNAL, 1968, 47 (03) : S140 - &
  • [39] Towards Clinical Cherenkov Emission Dosimetry: Stopping Power-To-Cherenkov Power Ratios and Beam Quality Specification of Clinical Electron Beams
    Zlateva, Y.
    Seuntjens, J.
    El Naqa, I.
    MEDICAL PHYSICS, 2016, 43 (06) : 3317 - 3317
  • [40] Photoacoustic dose monitoring in clinical high-energy photon beams
    Giza, Olivia M.
    Sanchez-Parcerisa, Daniel
    Sanchez-Tembleque, Victor
    Herraiz, Joaquin L.
    Camacho, Jorge
    Avery, Stephen
    Manuel Udias, Jose
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03):