Correlation of electron beam parameters with measured dose ratios in clinical photon beams

被引:0
|
作者
Deng, J [1 ]
Chen, Z [1 ]
Song, H [1 ]
Nath, R [1 ]
机构
[1] Yale Univ, Sch Med, New Haven, CT USA
关键词
D O I
10.1118/1.1997996
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work is to find a direct correlation between measured depth dose ratios and off axis ratios and two beam parameters for Monte Carlo simulations (i.e., the incident beam energy and radius) in clinical megavoltage photon beams in order to facilitate Monte Carlo applications in radiotherapy treatment planning. Method and Materials: The BEAM code was used to simulate the 6 MV photon beams from a Varian 2100C. A series of Monte Carlo simulations of Varian 2100C treatment head were performed for the incident beam energies from 5.1 MeV to 6.9 MeV and the beam radii from 0.03 cm to 0.12 cm. The calculated phase space files were then used for dose calculations in water. The depth dose ratio (DDR) defined as ratio of central axis depth dose at 20 cm to that at 10 cm and the off axis ratio (OAR) defined as ratio of dose at 10 cm in depth and 15 cm off axis to that at 10 cm on central axis as a function of incident electron beam energy and beam radius were studied. Results: For a fixed beam radius, the DDRs and OARs were linearly proportional to the incident beam energy for all the beam radii, with DDR = 0.5746 + 0.0072Ein and OAR = 1.4864 − 0.0824Ein, respectively. However, for a fixed incident beam energy, both DDRs and OARs were found to be virtually independent of incident beam radius, which is inconsistent with previously reported 18 MV photon beam in‐air results (Med. Phys. 29, 379, 2002). Conclusion: The OARs are more sensitive than the DDRs to the incident beam energy. However, both ratios are essentially independent of incident beam radius. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2011 / 2012
页数:2
相关论文
共 50 条
  • [21] DOSE CALCULATIONS FOR HIGH-ENERGY ELECTRON AND PHOTON BEAMS
    CUNNINGHAM, JR
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1989, 13 (03) : 241 - 250
  • [22] Application of measured pencil beam parameters for electron beam model evaluation
    Higgins, PD
    Gerbi, BJ
    Khan, FM
    MEDICAL PHYSICS, 2003, 30 (04) : 514 - 520
  • [23] Electron contamination in clinical high energy photon beams
    Sjogren, R
    Karlsson, M
    MEDICAL PHYSICS, 1996, 23 (11) : 1873 - 1881
  • [24] DOSE AND SHIELDING PARAMETERS OF ELECTRON-PHOTON STRAY RADIATION FROM A HIGH-ENERGY ELECTRON-BEAM
    DINTER, H
    TESCH, K
    NUCLEAR INSTRUMENTS & METHODS, 1977, 143 (02): : 349 - 355
  • [25] Skin dose estimation from 6MV photon beams for different clinical setup parameters
    Fayaz, Vahid
    Zandi, Hassan
    Tavakol, Asieh
    World Academy of Science, Engineering and Technology, 2011, 56 : 629 - 630
  • [26] Measured and Monte Carlo calculated output ratios in air for 6 and 18 MV photon beams
    Ding, G
    Yu, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1900 - 1900
  • [27] Volume dose ratios relevant for alanine dosimetry in small, 6 MV photon beams
    Cronholm, Rickard O.
    Andersen, Claus E.
    Behrens, Claus F.
    Helt-Hansen, Jakob
    RADIATION MEASUREMENTS, 2012, 47 (10) : 1014 - 1017
  • [28] A measured data set for evaluating electron beam dose algorithms
    Boyd, R
    Hogstrom, KR
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 231 - 233
  • [29] LIF SURFACE AND DEPTH DOSE MEASUREMENTS OF MEGAVOLTAGE PHOTON AND ELECTRON BEAMS
    KARTHA, M
    MACDONALD, JC
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1971, 10 (02): : 279 - +
  • [30] DOSE PERTURBATIONS AT INTERFACES IN PHOTON BEAMS - SECONDARY-ELECTRON TRANSPORT
    WERNER, BL
    DAS, IJ
    SALK, WN
    MEDICAL PHYSICS, 1990, 17 (02) : 212 - 226