Extraction of the photon spectra from measured beam parameters

被引:12
|
作者
Bloch, P [1 ]
McDonough, J [1 ]
机构
[1] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
关键词
x-ray spectrum; radiotherapy; spectrum reconstruction; transmission; buildup;
D O I
10.1118/1.598257
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Knowledge of the photon spectrum of a radiotherapy beam is often needed for three-dimensional (3-D) dose calculations using Monte Carlo methods and/or algorithms employing energy deposition kernels. Direct measurement of the x-ray energy fluence spectrum is not feasible for the high-energy photon beams used clinically. In this paper, the spectrum is extracted from basic beam data that are readily obtained for a clinical beam. We describe the photon spectrum using just two parameters. One parameter, which determines the high-energy part of the spectrum, is obtained using the measured dose in the buildup region for a small field, where electron contamination of the beam can be neglected. The other parameter is extracted from the photon beam attenuation in water. The results compare favorably to spectra generated from Monte Carlo simulations. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:752 / 757
页数:6
相关论文
共 50 条
  • [1] Extraction of the photon spectra from measured beam parameters
    University of Pennsylvania, Department of Radiation Oncology, Philadelphia, PA 19104-4283, United States
    Med. Phys., 5 (752-757):
  • [2] Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm
    Bloch, P
    Altschuler, MD
    Bjärngard, BE
    Kassaee, A
    McDonough, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01): : 171 - 183
  • [3] Calculation of a pencil beam kernel from measured photon beam data
    Storchi, PRM
    van Battum, LJ
    Woudstra, E
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12): : 2917 - 2928
  • [4] EXTRACTION OF WAVE PARAMETERS FROM MEASURED HF RADAR SEA-ECHO DOPPLER SPECTRA
    BARRICK, DE
    RADIO SCIENCE, 1977, 12 (03) : 415 - 424
  • [5] Correlation of electron beam parameters with measured dose ratios in clinical photon beams
    Deng, J
    Chen, Z
    Song, H
    Nath, R
    MEDICAL PHYSICS, 2005, 32 (06) : 2011 - 2012
  • [6] THE PHOTON SPECTRA FROM BEAM INTERACTIONS WITH MATTER AND RADIATION
    BEDNAREK, W
    GIOVANNELLI, F
    KARAKULA, S
    TKACZYK, W
    ASTRONOMY & ASTROPHYSICS, 1990, 236 (01) : 268 - 274
  • [7] EXTRACTION OF CRYSTAL PARAMETERS FROM EXAFS SPECTRA
    GURMAN, SJ
    PENDRY, JB
    SOLID STATE COMMUNICATIONS, 1976, 20 (03) : 287 - 290
  • [8] METHOD FOR EXTRACTING KINETIC-PARAMETERS FROM MEASURED IMPEDANCE SPECTRA
    KURZWEIL, P
    OBER, J
    WABNER, DW
    ELECTROCHIMICA ACTA, 1989, 34 (08) : 1179 - 1185
  • [9] On the problem of calculating the optical film parameters from the measured transmission spectra
    Vol'pyan, OD
    Yakovlev, PP
    OPTICS AND SPECTROSCOPY, 2002, 92 (01) : 109 - 111
  • [10] On the problem of calculating the optical film parameters from the measured transmission spectra
    O. D. Vol’pyan
    P. P. Yakovlev
    Optics and Spectroscopy, 2002, 92 : 109 - 111