Cone beam X-ray scatter removal via image frequency modulation and filtering

被引:17
|
作者
Bani-Hashemi, A
Blanz, E
Maltz, J
Hristov, D
Svatos, M
机构
关键词
D O I
10.1118/1.1998387
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a rapid method of patient scatter removal from cone beam (CB) projection images that requires no scatter measurement, physical modeling or strong assumptions regarding the spatial smoothness of the scatter distribution. Method and Materials: A modulator grid is placed between the imaged distribution and the detector that differentially frequency modulates primary and scattered photons. When photons travel through the grid, photons that originate directly from the CB source are modulated by a higher frequency than scattered photons that have more proximal, diffusely distributed sources. We employ non‐linear Fourier domain filtering to attenuate the contribution of scatter to the image spectrum. The theoretical validity of the method is verified using linear analysis of planar sources and its performance is evaluated using a simulator based on this analytical model. Results: Simulation experiments with an ideal modulator indicate that even unrealistically large amounts of scatter are almost entirely removed by this method. The recovered images are devoid of major artifacts and exhibit an RMS error of 10%. Conclusion: A disadvantage of the technique is that it will always produce a filtered image having at best 0.41 of the maximum detector resolution when maximum scatter rejection is desired. This is not a major issue in most medical X‐ray CB imaging applications using contemporary detector technology, especially since scatter often significantly reduces useful resolution. Conflict of Interest: Supported by Siemens Medical Solutions USA, Inc. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2093 / 2093
页数:1
相关论文
共 50 条
  • [1] Cone beam X-ray scatter removal via image frequency modulation and filtering
    Maltz, Jonathan S.
    Blanz, Wolf-Ekkehard
    Hristov, Dimitre
    Bani-Hashemi, Ali
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1854 - 1857
  • [2] Accelerated simulation of cone beam X-ray scatter projections
    Colijn, AP
    Beekman, FJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) : 584 - 590
  • [3] X-ray scatter correction algorithm for cone beam CT imaging
    Ning, R
    Tang, XY
    Conover, D
    [J]. MEDICAL PHYSICS, 2004, 31 (05) : 1195 - 1202
  • [4] X-ray scatter suppression algorithm for cone beam volume CT
    Ning, RL
    Tang, XY
    Conover, DL
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 774 - 781
  • [5] Evaluation of scatter mitigation strategies for X-ray cone-beam CT
    Lasio, G.
    Williamson, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2288 - 2289
  • [6] Scatter measurements and simulations in x-ray cone beam CT breast imaging
    Chen, Y.
    Liu, B.
    O'Connor, M.
    Didier, C.
    Glick, S.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2606 - 2606
  • [7] An enhancement method for X-ray image via fuzzy noise removal and homomorphic filtering
    Xiao, Limei
    Li, Ce
    Wu, Zongze
    Wang, Tian
    [J]. NEUROCOMPUTING, 2016, 195 : 56 - 64
  • [8] X-RAY SCATTER REMOVAL BY DECONVOLUTION
    SEIBERT, JA
    BOONE, JM
    [J]. MEDICAL PHYSICS, 1986, 13 (05) : 782 - 782
  • [9] X-RAY SCATTER REMOVAL BY DECONVOLUTION
    SEIBERT, JA
    BOONE, JM
    [J]. MEDICAL PHYSICS, 1988, 15 (04) : 567 - 575
  • [10] A beam stop based correction procedure for high spatial frequency scatter in industrial cone-beam X-ray CT
    Peterzol, A.
    Letang, J. M.
    Babot, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (18): : 4042 - 4054