Real-time D transesophageal echocardiography for the assessment of secundum atrial septal defects in children Three dimensional transesophageal echocardiography for assessment of atrial septa! defects

被引:0
|
作者
Kosger, Pelin [1 ]
Sulu, Ayse [1 ]
Akin, Tugcem [2 ]
Kiztanir, Hikmet [1 ]
Ucar, Birsen [1 ]
机构
[1] Eskisehir Osmangazi Univ, Fac Med, Dept Pediat Cardiol, Eskisehir, Turkey
[2] Eskisehir State Hosp, Pediat Cardiol Clin, Eskisehir, Turkey
关键词
ASD; Echocardiography; 3D TEE; Percutaneous closure; CONGENITAL HEART-DISEASE; TRANSCATHETER CLOSURE; DEVICE CLOSURE; OCCLUDER DEVICE; FEASIBILITY; EFFICACY; IMPACT;
D O I
10.4328/ACAM.20533
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: The need for more than one cross-section in the imaging of the atrial septum with two-dimensional (2D) echocardiography creates a limitation in determining the morphology of atrial septal defects (ASD) and negatively affects the success of the percutaneous closure procedure. In this study, measurements of ASDs and surrounding rims obtained by 3D transesophageal echocardiography (TEE) were compared with 2D TEE and angiographic balloon sizing measurements. Material and Methods: The study included 24 pediatric patients with the diagnosis of ASD who were scheduled for transcatheter defect closure. All patients underwent catheter-angiography following a detailed 2D TEE examination. Results: The data of 17 patients with optimal 3D TEE images were analyzed offline in the Q-lab. The diameter of the defects and surrounding rims, which were measured with two- and three-dimensional TEE were similar (p> 0.05). There was a strong correlation between the two measurement techniques in terms of defect diameter (r = 0.896, p <0.001). While the diameter of the defect measured by the sizing balloon was greater than that measured by 2D TEE, it was similar to that measured by 3D TEE (p <0.001, p = 0.14, respectively). There was also a strong correlation between the defect diameter measured by 3D TEE and balloon sizing diameter (r = 0.844. p <0.001). Discussion: The "en face" visualization of the atrial septum with 3D TEE provides adequate identification of the defect morphology and adjacent structures. Furthermore, reliable determination of the defect size by 3D imaging may lead to appropriate device selection without the requirement for invasive measurement techniques such as balloon sizing.
引用
收藏
页码:S301 / S305
页数:5
相关论文
共 50 条
  • [21] Comparison of transthoracic and transesophageal three-dimensional echocardiography for assessment of atrial septal defect diameter in children
    Acar, P
    Dulac, Y
    Roux, D
    Rougé, P
    Duterque, D
    Aggoun, Y
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (04): : 500 - +
  • [22] TRANSESOPHAGEAL ECHOCARDIOGRAPHIC ASSESSMENT OF PRIMUM, SECUNDUM AND SINUS VENOSUS ATRIAL SEPTAL-DEFECTS
    GNANAPRAGASAM, JP
    HOUSTON, AB
    NORTHRIDGE, DB
    JAMIESON, MPG
    POLLOCK, JCS
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1991, 31 (02) : 167 - 174
  • [23] Monitoring Complex Secundum Atrial Septal Defects Percutaneous Closure with Real Time Three-Dimensional Echocardiography
    Garcia-Fuertes, Daniel
    Mesa-Rubio, Dolores
    Ruiz-Ortiz, Martin
    Delgado-Ortega, Monica
    Tejero-Mateo, Ignacio
    Pan-Alvarez-Ossorio, Manuel
    Suarez-de-Lezo, Jose
    Lafuente, Mercedes
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (06): : 729 - 734
  • [24] Anatomic assessment of ostium secundum atrial septal defects with tridimensional echocardiography.
    Acar, P
    Piechaud, JF
    Bonhoeffer, P
    Aggoun, Y
    Bonnet, D
    Iserin, L
    Sidi, D
    Kachaner, J
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1998, 91 (05): : 543 - 550
  • [25] The role of three-dimensional transesophageal echocardiography in percutaneous closure of atrial septal defects associated with aneurysm of the atrial septum
    Costa, Catia
    Anjos, Rui
    Martins, Duarte
    Canada, Manuel
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2017, 36 (03) : 225 - 226
  • [26] Quantitative transesophageal three-dimensional color Doppler echocardiography for the calculation of shuntflow in atrial septal defects
    Hofmann, T
    Franzen, OW
    Knap, M
    Goldmann, B
    Meinertz, T
    CIRCULATION, 2000, 102 (18) : 630 - +
  • [27] Quantitative analysis of the morphology of secundum-type atrial septal defects and their dynamic change using transesophageal three-dimensional echocardiography
    Franke, A
    Kuhl, HP
    Rulands, D
    Jansen, C
    Erena, C
    Grabitz, RG
    Dabritz, S
    Messmer, BJ
    Flachskampf, FA
    Hanrath, P
    CIRCULATION, 1997, 96 (09) : 323 - 327
  • [28] Assessment of the morphology and mechanical function of the left atrial appendage by real-time three-dimensional transesophageal echocardiography
    Chen Ou-di
    Wu Wei-chun
    Jiang Yong
    Xiao Ming-hu
    Wang Hao
    CHINESE MEDICAL JOURNAL, 2012, 125 (19) : 3416 - 3420
  • [29] Assessment of the morphology and mechanical function of the left atrial appendage by real-time three-dimensional transesophageal echocardiography
    CHEN Ou-di
    WU Wei-chun
    JIANG Yong
    XIAO Ming-hu
    WANG Hao
    中华医学杂志(英文版), 2012, (19) : 3416 - 3420
  • [30] Assessment of atrial septal defect size and residual rim using real-time 3D transesophageal echocardiography
    Kaku K.
    Takeuchi M.
    Sugeng L.
    Lodato J.A.
    Nakai H.
    Weinert L.
    Otani K.
    Yoshitani H.
    Haruki N.
    Hijazi Z.M.
    Otsuji Y.
    Lang R.M.
    Journal of Echocardiography, 2009, 7 (3) : 48 - 54