Real-time D transesophageal echocardiography for the assessment of secundum atrial septal defects in children Three dimensional transesophageal echocardiography for assessment of atrial septa! defects

被引:0
|
作者
Kosger, Pelin [1 ]
Sulu, Ayse [1 ]
Akin, Tugcem [2 ]
Kiztanir, Hikmet [1 ]
Ucar, Birsen [1 ]
机构
[1] Eskisehir Osmangazi Univ, Fac Med, Dept Pediat Cardiol, Eskisehir, Turkey
[2] Eskisehir State Hosp, Pediat Cardiol Clin, Eskisehir, Turkey
关键词
ASD; Echocardiography; 3D TEE; Percutaneous closure; CONGENITAL HEART-DISEASE; TRANSCATHETER CLOSURE; DEVICE CLOSURE; OCCLUDER DEVICE; FEASIBILITY; EFFICACY; IMPACT;
D O I
10.4328/ACAM.20533
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: The need for more than one cross-section in the imaging of the atrial septum with two-dimensional (2D) echocardiography creates a limitation in determining the morphology of atrial septal defects (ASD) and negatively affects the success of the percutaneous closure procedure. In this study, measurements of ASDs and surrounding rims obtained by 3D transesophageal echocardiography (TEE) were compared with 2D TEE and angiographic balloon sizing measurements. Material and Methods: The study included 24 pediatric patients with the diagnosis of ASD who were scheduled for transcatheter defect closure. All patients underwent catheter-angiography following a detailed 2D TEE examination. Results: The data of 17 patients with optimal 3D TEE images were analyzed offline in the Q-lab. The diameter of the defects and surrounding rims, which were measured with two- and three-dimensional TEE were similar (p> 0.05). There was a strong correlation between the two measurement techniques in terms of defect diameter (r = 0.896, p <0.001). While the diameter of the defect measured by the sizing balloon was greater than that measured by 2D TEE, it was similar to that measured by 3D TEE (p <0.001, p = 0.14, respectively). There was also a strong correlation between the defect diameter measured by 3D TEE and balloon sizing diameter (r = 0.844. p <0.001). Discussion: The "en face" visualization of the atrial septum with 3D TEE provides adequate identification of the defect morphology and adjacent structures. Furthermore, reliable determination of the defect size by 3D imaging may lead to appropriate device selection without the requirement for invasive measurement techniques such as balloon sizing.
引用
收藏
页码:S301 / S305
页数:5
相关论文
共 50 条
  • [41] Prospective Randomized Trial of Transthoracic Echocardiography Versus Transesophageal Echocardiography for Assessment and Guidance of Transcatheter Closure of Atrial Septal Defects in Children Using the Amplatzer Septal Occluder
    Bartakian, Sergio
    El-Said, Howaida G.
    Printz, Beth
    Moore, John W.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (09) : 974 - 980
  • [42] Torn Atrial Septum during Transcatheter Closure of Atrial Septal Defect Visualized by Real-Time Three-Dimensional Transesophageal Echocardiography
    Kijima, Yasufumi
    Taniguchi, Manabu
    Akagi, Teiji
    Nakagawa, Koji
    Kusano, Kengo
    Ito, Hiroshi
    Sano, Shunji
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (11) : 1222.e5 - 1222.e8
  • [43] Transesophageal Real Time Three-Dimensional Echocardiography in Assessment of Partial Atrioventricular Septal Defect
    Piatkowski, Radoslaw
    Budaj-Fidecka, Anna
    Scislo, Piotr
    Kochanowski, Janusz
    Spiewak, Mateusz
    Opolski, Grzegorz
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (09): : 1092 - 1094
  • [44] Incremental Value of Live/Real Time Three-Dimensional over Two-Dimensional Transesophageal Echocardiography in the Assessment of Atrial Septal Pouch
    Elsayed, Mahmoud
    Hsiung, Ming C.
    Meggo-Quiroz, L. David
    Elguindy, Mostafa
    Uygur, Begum
    Tandon, Rohit
    Guvenc, Tolga
    Keser, Nurgul
    Vural, Mustafa G.
    Bulur, Serkan
    Chahwala, Jugal R.
    Abtahi, Firoozeh
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (12): : 1858 - 1867
  • [45] THE ASSESSMENT OF JUXTAPOSED ATRIAL APPENDAGES BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    STUMPER, O
    RIJLAARSDAM, M
    VARGASBARRON, J
    ROMERO, A
    HESS, J
    SUTHERLAND, GR
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1990, 29 (03) : 365 - 371
  • [46] Assessment of the left atrial appendage structure and function of the non-valvular atrial fibrillation by real-time three-dimensional transesophageal echocardiography
    Chen, Zhongxiu
    Bai, Wenjuan
    Wang, Hui
    Li, Chen
    Cheng, Wei
    Tang, Hong
    Rao, Li
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C189 - C190
  • [47] 4-D echocardiography in assessment of ventricular and atrial septal defects
    Mozaeva, N
    Duzikov, A
    Nelassov, N
    Kislitsky, A
    Mozaev, I
    EUROPEAN HEART JOURNAL, 2004, 25 : 270 - 270
  • [48] En Face View of Atrial Septal Defect by Two-Dimensional Transthoracic Echocardiography: Comparison to Real-Time Three-Dimensional Transesophageal Echocardiography
    Huang, Xinsheng
    Shen, Junjun
    Huang, Yigao
    Zheng, Zhichao
    Fei, Hongwen
    Hou, Yueshuang
    Xu, Yan
    Huang, Tao
    Huang, Wenhui
    Zhang, Caojin
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (07) : 714 - 721
  • [49] Multiperforated atrial septal "aneurysm in aneurysm": Percutaneous closure guided by real-time three-dimensional transesophageal echocardiography
    Sun, Feifei
    Fan, Miao
    Li, Ying
    Ren, Weidong
    Chen, Yanli
    JOURNAL OF CLINICAL ULTRASOUND, 2018, 46 (06) : 421 - 423
  • [50] Echocardiographic guidance of transcatheter closure of atrial septal defects: Is intracardiac echocardiography better than transesophageal echocardiography?
    Koenig, P
    Cao, QL