Assessment of the morphology and mechanical function of the left atrial appendage by real-time three-dimensional transesophageal echocardiography

被引:16
|
作者
Chen Ou-di [1 ,2 ,3 ,4 ]
Wu Wei-chun [1 ,2 ]
Jiang Yong [1 ,2 ]
Xiao Ming-hu [1 ,2 ]
Wang Hao [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Dept Echocardiog, State Key Lab Cardiovasc Dis, Natl Ctr Cardiovasc Dis,Fuwai Hosp, Beijing 100037, Peoples R China
[2] Peking Union Med Coll, Beijing 100037, Peoples R China
[3] Gen Hosp, Cardiovasc Inst, Guangzhou 510080, Guangdong, Peoples R China
[4] Acad Med Sci Guangdong Prov, Guangzhou 510080, Guangdong, Peoples R China
关键词
real-time three-dimensional transesophageal echocardiography; left atrial appendage; function; SINUS RHYTHM; MITRAL-VALVE; FIBRILLATION; OCCLUSION; EVOLUTION; DEVICES; STROKE; RISK; FLOW;
D O I
10.3760/cma.j.issn.0366-6999.2012.19.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The left atrial appendage (LAA) is an important source of thrombus formation. We investigated the feasibility of the recently developed real-time three-dimensional transesophageal echocardiography (RT3D-TEE) method in assessment of the morphology and function of the LAA. Methods Ninety-six consecutive patients (58 males with a mean age of (43.4 +/- 12.5) years) who were referred for 2-dimensional (2D) transesophageal echocardiography (TEE) underwent additional RT3D-TEE. LAA morphology was visualized in multiple views. Orifice size, depth, volumes and ejection fraction (EF) of the LAA, were measured. Results All the patients underwent RT3D-TEE examination without complications. Ninety-two patients (95.8%) had adequate images for visualization and quantitative analysis of the LAA. The LAA exhibited great variability with respect to relative dimensions and morphology. LAA orifice area was (3.8 +/- 1.2) cm(2) with a diameter of (2.4 +/- 0.9) cm x (1.4 +/- 0.6) cm. The mean depth of the LAA was (2.9 +/- 0.7) cm. End-diastolic volume (EDV-LAA), end-systolic volume (ESV-LAA) and EF of the LAA were (6.2 +/- 3.7) ml, (4.1 +/- 2.8) ml, and 0.35 +/- 0.16, respectively. EDV-LAA, ESV-LAA and the orifice area of the LAA in patients with atrial fibrillation (AF) were larger than those without AF, whereas the EF was smaller in the AF patients. Conclusions Defining LAA morphology and quantitative analysis of the size and function of the LAA with superior quality and resolution of images using RT3D-TEE is feasible. This technique may be an ideal tool for guidance of the LAA occlusion procedure. Determination of LAA volumes and volume-derived EF by RT3D-TEE provides new insights into the analysis of LAA function. Chin Med J 2012;125(19):3416-3420
引用
收藏
页码:3416 / 3420
页数:5
相关论文
共 50 条
  • [1] Assessment of the morphology and mechanical function of the left atrial appendage by real-time three-dimensional transesophageal echocardiography
    CHEN Ou-di
    WU Wei-chun
    JIANG Yong
    XIAO Ming-hu
    WANG Hao
    [J]. 中华医学杂志(英文版), 2012, (19) : 3416 - 3420
  • [2] Assessment of the left atrial appendage structure and morphology: comparison of real-time three-dimensional transesophageal echocardiography and computed tomography
    Wenjuan Bai
    Zhongxiu Chen
    Hong Tang
    Hui Wang
    Wei Cheng
    Li Rao
    [J]. The International Journal of Cardiovascular Imaging, 2017, 33 : 623 - 633
  • [3] Assessment of the left atrial appendage structure and morphology: comparison of real-time three-dimensional transesophageal echocardiography and computed tomography
    Bai, Wenjuan
    Chen, Zhongxiu
    Tang, Hong
    Wang, Hui
    Cheng, Wei
    Rao, Li
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (05): : 623 - 633
  • [4] Assessment of the Left Atrial Appendage using Real-time Three Dimensional Transesophageal Echocardiography
    Bai Wenjuan
    Chen Zhongxiu
    Wang Hui
    Wei Xin
    Rao Li
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C227 - C227
  • [5] Assessment of the left atrial appendage using real-time three dimensional transesophageal echocardiography
    Bai, Wenjuan
    Chen, Zhongxiu
    Wang, Hui
    Wei, Xin
    Rao, Li
    [J]. CARDIOLOGY, 2014, 129 : 128 - 128
  • [6] Real-Time Three-Dimensional Transesophageal Echocardiography and a Congenital Bilobar Left Atrial Appendage
    Cummisford, Kevin
    Sundar, Sugantha
    Hagberg, Robert
    Mahmood, Feroze
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (03) : 475 - 477
  • [7] Analysis of real-time three dimensional transesophageal echocardiography in the assessment of left atrial appendage function in patients with atrial fibrillation
    Gan, Lin
    Yu, Lan
    Xie, Manying
    Feng, Wei
    Yin, Jiabao
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2016, 12 (05) : 3323 - 3327
  • [8] Assessment of the left atrial appendage structure and function of the non-valvular atrial fibrillation by real-time three-dimensional transesophageal echocardiography
    Chen, Zhongxiu
    Bai, Wenjuan
    Wang, Hui
    Li, Chen
    Cheng, Wei
    Tang, Hong
    Rao, Li
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C189 - C190
  • [9] Relationship Between Left Appendage Volume and Function, and Left Atrial Function: A Real-Time Three-Dimensional Transesophageal Echocardiography Study
    Fukuoka, Yoko
    Izumo, Masaki
    Saitoh, Takeji
    Kuwahara, Eiji
    Tanaka, Jun
    Gurudevan, Swaminatha V.
    Tolstrup, Kirsten
    Siegel, Robert J.
    Shiota, Takahiro
    [J]. CIRCULATION, 2011, 124 (21)
  • [10] Thrombus or Bilobar Left Atrial Appendage? Diagnosis by Real-Time Three-Dimensional Transesophageal Echocardiography
    Mizuguchi, K. Annette
    Burch, Thomas M.
    Bulwer, Bernard E.
    Fox, Amanda A.
    Rizzo, Robert J.
    Shernan, Stanton K.
    [J]. ANESTHESIA AND ANALGESIA, 2009, 108 (01): : 70 - 72