Assessment of the morphology and mechanical function of the left atrial appendage by real-time three-dimensional transesophageal echocardiography

被引:16
|
作者
Chen Ou-di [1 ,2 ,3 ,4 ]
Wu Wei-chun [1 ,2 ]
Jiang Yong [1 ,2 ]
Xiao Ming-hu [1 ,2 ]
Wang Hao [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Dept Echocardiog, State Key Lab Cardiovasc Dis, Natl Ctr Cardiovasc Dis,Fuwai Hosp, Beijing 100037, Peoples R China
[2] Peking Union Med Coll, Beijing 100037, Peoples R China
[3] Gen Hosp, Cardiovasc Inst, Guangzhou 510080, Guangdong, Peoples R China
[4] Acad Med Sci Guangdong Prov, Guangzhou 510080, Guangdong, Peoples R China
关键词
real-time three-dimensional transesophageal echocardiography; left atrial appendage; function; SINUS RHYTHM; MITRAL-VALVE; FIBRILLATION; OCCLUSION; EVOLUTION; DEVICES; STROKE; RISK; FLOW;
D O I
10.3760/cma.j.issn.0366-6999.2012.19.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The left atrial appendage (LAA) is an important source of thrombus formation. We investigated the feasibility of the recently developed real-time three-dimensional transesophageal echocardiography (RT3D-TEE) method in assessment of the morphology and function of the LAA. Methods Ninety-six consecutive patients (58 males with a mean age of (43.4 +/- 12.5) years) who were referred for 2-dimensional (2D) transesophageal echocardiography (TEE) underwent additional RT3D-TEE. LAA morphology was visualized in multiple views. Orifice size, depth, volumes and ejection fraction (EF) of the LAA, were measured. Results All the patients underwent RT3D-TEE examination without complications. Ninety-two patients (95.8%) had adequate images for visualization and quantitative analysis of the LAA. The LAA exhibited great variability with respect to relative dimensions and morphology. LAA orifice area was (3.8 +/- 1.2) cm(2) with a diameter of (2.4 +/- 0.9) cm x (1.4 +/- 0.6) cm. The mean depth of the LAA was (2.9 +/- 0.7) cm. End-diastolic volume (EDV-LAA), end-systolic volume (ESV-LAA) and EF of the LAA were (6.2 +/- 3.7) ml, (4.1 +/- 2.8) ml, and 0.35 +/- 0.16, respectively. EDV-LAA, ESV-LAA and the orifice area of the LAA in patients with atrial fibrillation (AF) were larger than those without AF, whereas the EF was smaller in the AF patients. Conclusions Defining LAA morphology and quantitative analysis of the size and function of the LAA with superior quality and resolution of images using RT3D-TEE is feasible. This technique may be an ideal tool for guidance of the LAA occlusion procedure. Determination of LAA volumes and volume-derived EF by RT3D-TEE provides new insights into the analysis of LAA function. Chin Med J 2012;125(19):3416-3420
引用
收藏
页码:3416 / 3420
页数:5
相关论文
共 50 条
  • [41] Evaluation of left atrial systolic function in noncompaction cardiomyopathy by real-time three-dimensional echocardiography
    Attila Nemes
    Ashraf M. Anwar
    Kadir Caliskan
    Osama I. I. Soliman
    Bas M. van Dalen
    Marcel L. Geleijnse
    Folkert J. ten Cate
    [J]. The International Journal of Cardiovascular Imaging, 2008, 24 : 237 - 242
  • [42] Role of three-dimensional transoesophageal echocardiography in the evaluation of left atrial appendage morphology
    Petersen, M.
    Roehrich, A.
    Aissa, J.
    Kroepil, P.
    Antoch, G.
    Verde, P.
    Ohmann, C.
    Kelm, M.
    Kehmeier, E. S.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 39 - 40
  • [43] Real-Time Three-Dimensional Transesophageal Echocardiography in the Assessment of Mechanical Prosthetic Mitral Valve Ring Thrombosis
    Oezkan, Mehmet
    Guersoy, Ozan Mustafa
    Astarcioglu, Mehmet Ali
    Guenduez, Sabahattin
    Cakal, Beytullah
    Karakoyun, Sueleyman
    Kalcik, Macit
    Kahveci, Goekhan
    Duran, Niluefer Eksi
    Yildiz, Mustafa
    Cevik, Cihan
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (07): : 977 - 983
  • [44] Three-dimensional echocardiography of left atrial appendage thrombus
    Khan, GN
    Dairywala, IT
    Liu, Z
    Li, P
    Carroll, J
    Vannan, MA
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (02): : 163 - 166
  • [45] Real-time Three-Dimensional Transesophageal Echocardiography: The Matrix Revolution
    Fischer, Gregory W.
    Salgo, Ivan S.
    Adams, David H.
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (06) : 904 - 912
  • [46] Real-time three-dimensional transesophageal echocardiography of the Gerbode defect
    Millan, Raul
    Pericas, Pere
    Forteza, Jose F.
    Rodriguez, Antonio
    Pascual, Marcos
    Vidal, Laura
    Bonnin, Oriol
    Bethencourt, Armando
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (03) : E52 - E53
  • [47] Clinical application of transesophageal real-time three-dimensional echocardiography
    Wang, H.
    Chen, O.
    Jiang, Y.
    Duan, F. J.
    Ye, Z. K.
    Wang, Z. M.
    Wang, Y.
    Cui, Q. Q.
    Lu, X. Z.
    Li, J. R.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 125 : S68 - S68
  • [48] Assessment of left ventricular dyssynchrony by real-time three-dimensional echocardiography
    Delgado, Victoria
    Sitges, Marta
    Vidal, Barbara
    Silva, Etelvino
    Azqueta, Manuel
    Tolosana, Jose M.
    Mont, Lluis
    Pare, Carles
    Brugada, Josep
    [J]. REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (08): : 825 - 834
  • [49] Left ventricular mass assessment by real-time three-dimensional echocardiography
    Singh, Anurag
    Pothineni, Koteswara R.
    Panwar, Sadik R.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08): : 1180 - 1181
  • [50] Quantitative Assessment of Left Ventricle by Real-time Three-dimensional Echocardiography
    Lin, Lung-Chun
    Liau, Chiau-Suong
    Lee, Yuan-Teh
    [J]. JOURNAL OF MEDICAL ULTRASOUND, 2007, 15 (01) : 19 - 30