Real-Time Three-Dimensional Transesophageal Echocardiography in the Assessment of Mechanical Prosthetic Mitral Valve Ring Thrombosis

被引:46
|
作者
Oezkan, Mehmet [1 ]
Guersoy, Ozan Mustafa [1 ]
Astarcioglu, Mehmet Ali [1 ]
Guenduez, Sabahattin [1 ]
Cakal, Beytullah [1 ]
Karakoyun, Sueleyman [1 ]
Kalcik, Macit [1 ]
Kahveci, Goekhan [1 ]
Duran, Niluefer Eksi [1 ]
Yildiz, Mustafa [1 ]
Cevik, Cihan [2 ]
机构
[1] Kosuyolu Kartal Heart Training & Res Hosp, Dept Cardiol, Istanbul, Turkey
[2] St Lukes Episcopal Hosp, Texas Heart Inst, Dept Cardiol, Houston, TX USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2013年 / 112卷 / 07期
关键词
THROMBOLYTIC TREATMENT; MANAGEMENT; GUIDELINES; AMERICAN; PATIENT;
D O I
10.1016/j.amjcard.2013.05.032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although 2-dimensional (2D) transesophageal echocardiography (TEE) is the gold standard for the diagnosis of prosthetic valve thrombosis, nonobstructive clots located on mitral valve rings can be missed. Real-time 3-dimensional (3D) TEE has incremental value in the visualization of mitral prosthesis. The aim of this study was to investigate the utility of real-time 3D TEE in the diagnosis of mitral prosthetic ring thrombosis. The clinical outcomes of these patients in relation to real-time 3D transesophageal echocardiographic findings were analyzed. Of 1,263 patients who underwent echocardiographic studies, 174 patients (37 men, 137 women) with mitral ring thrombosis detected by real-time 3D TEE constituted the main study population. Patients were followed prospectively on oral anticoagulation for 25 +/- 7 months. Eighty-nine patients (51%) had thrombi that were missed on 2D TEE and depicted only on real-time 3D TEE. The remaining cases were partially visualized with 2D TEE but completely visualized with real-time 3D TEE. Thirty-seven patients (21%) had thromboembolism. The mean thickness of the ring thrombosis in patients with thromboembolism was greater than that in patients without thromboembolism (3.8 +/- 0.9 vs 2.8 +/- 0.7 mm, p <0.001). One hundred fifty-five patients (89%) underwent real-time 3D TEE during follow-up. There were no thrombi in 39 patients (25%); 45 (29%) had regression of thrombi, and there was no change in thrombus size in 68 patients (44%). Thrombus size increased in 3 patients (2%). Thrombosis was confirmed surgically and histopathologically in 12 patients (7%). In conclusion, real-time 3D TEE can detect prosthetic mitral ring thrombosis that could be missed on 2D TEE and cause thromboembolic events. (c) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:977 / 983
页数:7
相关论文
共 50 条
  • [1] Thrombosis of a bileaflet prosthetic mitral valve: a real-time three-dimensional transesophageal echocardiography perspective
    Biswajit Paul
    Anil Minocha
    [J]. The International Journal of Cardiovascular Imaging, 2010, 26 : 367 - 368
  • [2] Thrombosis of a bileaflet prosthetic mitral valve: a real-time three-dimensional transesophageal echocardiography perspective
    Paul, Biswajit
    Minocha, Anil
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (04): : 367 - 368
  • [3] Real-time three-dimensional transesophageal echocardiography in the assessment of tricuspid mechanical prosthetic valve
    Ozkan, Mehmet
    Gokdeniz, Tayyar
    Yildiz, Mustafa
    Duran, Nilufer Eksi
    [J]. TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2009, 37 (04): : 283 - 283
  • [4] Prosthetic mitral valve obstruction: diagnosis with real-time three-dimensional transesophageal echocardiography
    Aytekin, Saide
    Yurdakul, Selen
    Tayyareci, Yelda
    [J]. ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2013, 13 (01): : E6 - E6
  • [5] Assessment of mitral prosthetic valve thrombosis by live three-dimensional echocardiography: comparison with transesophageal echocardiography
    Moreo, Antonella
    Lobiati, Elisabetta
    De Chiara, Benedetta
    Mauri, Francesco
    [J]. HEART AND VESSELS, 2007, 22 (04) : 287 - 289
  • [6] Assessment of mitral prosthetic valve thrombosis by live three-dimensional echocardiography: comparison with transesophageal echocardiography
    Antonella Moreo
    Elisabetta Lobiati
    Benedetta De Chiara
    Francesco Mauri
    [J]. Heart and Vessels, 2007, 22 : 287 - 289
  • [7] Real-time three-dimensional transesophageal echocardiography in the evaluation of mechanical prosthetic mitral valve ring thrombosis: an echo-morphologic study of the danger lying in ambush
    Gursoy, M. O.
    Astarcioglu, M. A.
    Gunduz, S.
    Bayram, Z.
    Cakal, B.
    Karakoyun, S.
    Kalcik, M.
    Yesin, M.
    Yildiz, M.
    Ozkan, M.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 : 105 - 105
  • [8] Real-Time Three-Dimensional Transesophageal Echocardiography in the Intraoperative Assessment of Mitral Valve Disease
    Grewal, Jasmine
    Mankad, Sunil
    Freeman, William K.
    Click, Roger L.
    Suri, Rakesh M.
    Abel, Martin D.
    Oh, Jae K.
    Pellikka, Patricia A.
    Nesbitt, Gillian C.
    Syed, Imran
    Mulvagh, Sharon L.
    Miller, Fletcher A.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) : 34 - 41
  • [9] Role of real-time three-dimensional transesophageal echocardiography in mitral valve repair
    Cuizhen Pan~1 Xianhong Shu~1 Qiling Cao~2 Chunsheng Wang~1 Wenjun Ding~1 Haozhu Chen~1 1 Department of Echocardiography
    [J]. Journal of Geriatric Cardiology, 2008, (03) : 137 - 141
  • [10] Diagnostic assessment of prosthetic mitral valve thrombosis by real-time three-dimensional transoesophageal echocardiography and successful thrombolytic treatment
    Morais, Humberto
    Martins, Telmo
    Roberto, Jose
    Caceres-Loriga, Fidel
    [J]. CARDIOVASCULAR JOURNAL OF AFRICA, 2011, 22 (06) : 340 - 342