Reliability and Validity of the CORE Sensor to Assess Core Body Temperature during Cycling Exercise

被引:28
|
作者
Verdel, Nina [1 ]
Podlogar, Tim [2 ,3 ,4 ]
Ciuha, Ursa [3 ]
Holmberg, Hans-Christer [5 ]
Debevec, Tadej [3 ,6 ]
Supej, Matej [1 ,6 ]
机构
[1] Mid Sweden Univ, Swedish Winter Sports Res Ctr, S-83125 Ostersund, Sweden
[2] Univ Primorska, Fac Hlth Sci, Izola 6310, Slovenia
[3] Jozef Stefan Inst, Dept Automat Biocybernet & Robot, Ljubljana 1000, Slovenia
[4] Human Performance Ctr, Ljubljana 1000, Slovenia
[5] Lulea Univ Technol, Dept Hlth Med & Rehabil, S-97187 Lulea, Sweden
[6] Univ Ljubljana, Fac Sport, Ljubljana 1000, Slovenia
基金
欧盟地平线“2020”;
关键词
validity; reliability; core body temperature; rectal temperature; CORE sensor; cycling; non-invasive; INTESTINAL TEMPERATURE; RECTAL TEMPERATURE; TELEMETRY PILL; HEAT ILLNESS; ESOPHAGEAL; DEVICES; SKIN;
D O I
10.3390/s21175932
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring core body temperature (T-c) during training and competitions, especially in a hot environment, can help enhance an athlete's performance, as well as lower the risk for heat stroke. Accordingly, a noninvasive sensor that allows reliable monitoring of T-c would be highly beneficial in this context. One such novel non-invasive sensor was recently introduced onto the market (CORE, greenTEG, Rumlang, Switzerland), but, to our knowledge, a validation study of this device has not yet been reported. Therefore, the purpose of this study was to evaluate the validity and reliability of the CORE sensor. In Study I, 12 males were subjected to a low-to-moderate heat load by performing, on two separate occasions several days apart, two identical 60-min bouts of steady-state cycling in the laboratory at 19 degrees C and 30% relative humidity. In Study II, 13 males were subjected to moderate-to-high heat load by performing 90 min of cycling in the laboratory at 31 degrees C and 39% relative humidity. In both cases the core body temperatures indicated by the CORE sensor were compared to the corresponding values obtained using a rectal sensor (T-rec). The first major finding was that the reliability of the CORE sensor is acceptable, since the mean bias between the two identical trials of exercise (0.02 degrees C) was not statistically significant. However, under both levels of heat load, the body temperature indicated by the CORE sensor did not agree well with T-rec, with approximately 50% of all paired measurements differing by more than the predefined threshold for validity of <= 0.3 degrees C. In conclusion, the results obtained do not support the manufacturer's claim that the CORE sensor provides a valid measure of core body temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Changes of body core temperature and intraperitoneal milieu during pneumoperitoneum
    Gründel, K
    Böhm, B
    Junghans, T
    Schwenk, W
    Müller, JM
    LANGENBECKS ARCHIVES OF SURGERY, 1999, : 209 - 215
  • [42] Regularization of body core temperature prediction during physical activity
    Gribok, Andrei
    McKenna, Thomas
    Reifman, Jaques
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2130 - +
  • [43] Do Humans With a Patent Foramen Ovale Have a Higher Core Body Temperature During Rest, Exercise and Post-Exercise?
    Davis, James
    Ng, Chi-Yan A.
    Hill, Sierra D.
    Lovering, Andrew T.
    FASEB JOURNAL, 2013, 27
  • [44] Cooling During Endurance Cycling in the Heat: Blunted Core Temperature but Not Inflammatory Responses
    Keller, Sebastian
    Kohne, Simon
    Notbohm, Hannah L.
    Bloch, Wilhelm
    Schumann, Moritz
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2021, 16 (06) : 865 - 870
  • [45] Validity of Core Temperature Measurements at 3 Rectal Depths During Rest, Exercise, Cold-Water Immersion, and Recovery
    Miller, Kevin C.
    Hughes, Lexie E.
    Long, Blaine C.
    Adams, William M.
    Casa, Douglas J.
    JOURNAL OF ATHLETIC TRAINING, 2017, 52 (04) : 332 - 338
  • [46] Exercise Core Temperature Response with a Simulated Burn Injury: Effect of Body Size
    Cramer, Matthew N.
    Moralez, Gilbert
    Huang, Mu
    Kouda, Ken
    Poh, Paula Y. S.
    Crandall, Craig G.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2020, 52 (03): : 705 - 711
  • [47] Body core temperature of rats subjected to daily exercise limited to a fixed time
    O. Shido
    Naotoshi Sugimoto
    Sotaro Sakurada
    Yoshiko Kaneko
    Tetsuo Nagasaka
    International Journal of Biometeorology, 1997, 40 : 135 - 140
  • [48] Body core temperature of rats subjected to daily exercise limited to a fixed time
    Shido, O
    Sugimoto, N
    Sakurada, S
    Kaneko, Y
    Nagasaka, T
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1997, 40 (03) : 135 - 140
  • [49] The impact of exercise-induced core body temperature elevations on coagulation responses
    Veltmeijer, Matthijs T. W.
    Eijsvogels, Thijs M. H.
    Barteling, Wideke
    Verbeek-Knobbe, Kitty
    van Heerde, Waander L.
    Hopman, Maria T. E.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2017, 20 (02) : 202 - 207
  • [50] Caffeine Alters Core Temperature and RPE during Thermally Exhaustive Exercise
    Juarez, Danna G.
    Polin, Max
    Parker, Daryl
    Quintana, Roberto
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 62 - 62