Reliability and Validity of the CORE Sensor to Assess Core Body Temperature during Cycling Exercise

被引:28
|
作者
Verdel, Nina [1 ]
Podlogar, Tim [2 ,3 ,4 ]
Ciuha, Ursa [3 ]
Holmberg, Hans-Christer [5 ]
Debevec, Tadej [3 ,6 ]
Supej, Matej [1 ,6 ]
机构
[1] Mid Sweden Univ, Swedish Winter Sports Res Ctr, S-83125 Ostersund, Sweden
[2] Univ Primorska, Fac Hlth Sci, Izola 6310, Slovenia
[3] Jozef Stefan Inst, Dept Automat Biocybernet & Robot, Ljubljana 1000, Slovenia
[4] Human Performance Ctr, Ljubljana 1000, Slovenia
[5] Lulea Univ Technol, Dept Hlth Med & Rehabil, S-97187 Lulea, Sweden
[6] Univ Ljubljana, Fac Sport, Ljubljana 1000, Slovenia
基金
欧盟地平线“2020”;
关键词
validity; reliability; core body temperature; rectal temperature; CORE sensor; cycling; non-invasive; INTESTINAL TEMPERATURE; RECTAL TEMPERATURE; TELEMETRY PILL; HEAT ILLNESS; ESOPHAGEAL; DEVICES; SKIN;
D O I
10.3390/s21175932
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring core body temperature (T-c) during training and competitions, especially in a hot environment, can help enhance an athlete's performance, as well as lower the risk for heat stroke. Accordingly, a noninvasive sensor that allows reliable monitoring of T-c would be highly beneficial in this context. One such novel non-invasive sensor was recently introduced onto the market (CORE, greenTEG, Rumlang, Switzerland), but, to our knowledge, a validation study of this device has not yet been reported. Therefore, the purpose of this study was to evaluate the validity and reliability of the CORE sensor. In Study I, 12 males were subjected to a low-to-moderate heat load by performing, on two separate occasions several days apart, two identical 60-min bouts of steady-state cycling in the laboratory at 19 degrees C and 30% relative humidity. In Study II, 13 males were subjected to moderate-to-high heat load by performing 90 min of cycling in the laboratory at 31 degrees C and 39% relative humidity. In both cases the core body temperatures indicated by the CORE sensor were compared to the corresponding values obtained using a rectal sensor (T-rec). The first major finding was that the reliability of the CORE sensor is acceptable, since the mean bias between the two identical trials of exercise (0.02 degrees C) was not statistically significant. However, under both levels of heat load, the body temperature indicated by the CORE sensor did not agree well with T-rec, with approximately 50% of all paired measurements differing by more than the predefined threshold for validity of <= 0.3 degrees C. In conclusion, the results obtained do not support the manufacturer's claim that the CORE sensor provides a valid measure of core body temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Validity of a Tympanic Thermometer and Thermal Imaging Camera for Measuring Core and Skin Temperature during Exercise in the Heat
    Fenemor, Stephen P.
    Gill, Nicholas D.
    Sims, Stacy T.
    Beaven, C. Martyn
    Driller, Matthew W.
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2020, 24 (01) : 49 - 55
  • [22] Robust Skin Attachable Sensor for Core Body Temperature Monitoring
    Tanaka, Y.
    Matsunaga, D.
    Tajima, T.
    Seyama, M.
    IEEE SENSORS JOURNAL, 2021, 21 (14) : 16118 - 16123
  • [23] Measuring core body temperature with a non-invasive sensor
    Mazgaoker, Savyon
    Ketko, Itay
    Yanovich, Ran
    Heled, Yuval
    Epstein, Yoram
    JOURNAL OF THERMAL BIOLOGY, 2017, 66 : 17 - 20
  • [24] Body Core Temperature Sensing: Challenges and new Sensor Technologies
    Uth, Marc-Florian
    Koch, Jochim
    Sattler, Frank
    PROCEEDINGS OF THE 30TH ANNIVERSARY EUROSENSORS CONFERENCE - EUROSENSORS 2016, 2016, 168 : 89 - 92
  • [25] Core temperature response to cycling exercise: Effect of time of day and measurement site
    Chapon, P. -A.
    Bessot, N.
    Gauthier, A.
    Kauffman, F.
    Sesbouee, B.
    Moussay, S.
    JOURNAL OF THERMAL BIOLOGY, 2012, 37 (04) : 355 - 360
  • [26] Body core temperature during food restriction in rats
    Severinsen, T
    Munch, IC
    ACTA PHYSIOLOGICA SCANDINAVICA, 1999, 165 (03): : 299 - 305
  • [27] Core body temperature during menopausal hot flushes
    Freedman, RR
    Woodward, S
    FERTILITY AND STERILITY, 1996, 65 (06) : 1141 - 1144
  • [28] Regulation of core body temperature during whole body hyperthermia by oesophageal temperature feedback
    Schuette, W.H.
    Lees, D.E.
    Bull, J.M.
    Medical and Biological Engineering and Computing, 1980, 18 (03): : 299 - 302
  • [29] Validity of Telemetry Measurement of Core Body Temperature in Persons with Spinal Cord Injury
    Lee, Ingrid
    Chang, Cally
    Stambouli, Lee
    Kumar, Nina
    Graham, Marin
    Leung, Patricia
    Bauman, William
    Handrakis, John
    FASEB JOURNAL, 2020, 34
  • [30] Wearable Sensor Technology to Predict Core Body Temperature: A Systematic Review
    Dolson, Conor M.
    Harlow, Ethan R.
    Phelan, Dermot M.
    Gabbett, Tim J.
    Gaal, Benjamin
    McMellen, Christopher
    Geletka, Benjamin J.
    Calcei, Jacob G.
    Voos, James E.
    Seshadri, Dhruv R.
    SENSORS, 2022, 22 (19)