Reliability and Validity of the CORE Sensor to Assess Core Body Temperature during Cycling Exercise

被引:28
|
作者
Verdel, Nina [1 ]
Podlogar, Tim [2 ,3 ,4 ]
Ciuha, Ursa [3 ]
Holmberg, Hans-Christer [5 ]
Debevec, Tadej [3 ,6 ]
Supej, Matej [1 ,6 ]
机构
[1] Mid Sweden Univ, Swedish Winter Sports Res Ctr, S-83125 Ostersund, Sweden
[2] Univ Primorska, Fac Hlth Sci, Izola 6310, Slovenia
[3] Jozef Stefan Inst, Dept Automat Biocybernet & Robot, Ljubljana 1000, Slovenia
[4] Human Performance Ctr, Ljubljana 1000, Slovenia
[5] Lulea Univ Technol, Dept Hlth Med & Rehabil, S-97187 Lulea, Sweden
[6] Univ Ljubljana, Fac Sport, Ljubljana 1000, Slovenia
基金
欧盟地平线“2020”;
关键词
validity; reliability; core body temperature; rectal temperature; CORE sensor; cycling; non-invasive; INTESTINAL TEMPERATURE; RECTAL TEMPERATURE; TELEMETRY PILL; HEAT ILLNESS; ESOPHAGEAL; DEVICES; SKIN;
D O I
10.3390/s21175932
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring core body temperature (T-c) during training and competitions, especially in a hot environment, can help enhance an athlete's performance, as well as lower the risk for heat stroke. Accordingly, a noninvasive sensor that allows reliable monitoring of T-c would be highly beneficial in this context. One such novel non-invasive sensor was recently introduced onto the market (CORE, greenTEG, Rumlang, Switzerland), but, to our knowledge, a validation study of this device has not yet been reported. Therefore, the purpose of this study was to evaluate the validity and reliability of the CORE sensor. In Study I, 12 males were subjected to a low-to-moderate heat load by performing, on two separate occasions several days apart, two identical 60-min bouts of steady-state cycling in the laboratory at 19 degrees C and 30% relative humidity. In Study II, 13 males were subjected to moderate-to-high heat load by performing 90 min of cycling in the laboratory at 31 degrees C and 39% relative humidity. In both cases the core body temperatures indicated by the CORE sensor were compared to the corresponding values obtained using a rectal sensor (T-rec). The first major finding was that the reliability of the CORE sensor is acceptable, since the mean bias between the two identical trials of exercise (0.02 degrees C) was not statistically significant. However, under both levels of heat load, the body temperature indicated by the CORE sensor did not agree well with T-rec, with approximately 50% of all paired measurements differing by more than the predefined threshold for validity of <= 0.3 degrees C. In conclusion, the results obtained do not support the manufacturer's claim that the CORE sensor provides a valid measure of core body temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Non-invasive Core Body Temperature Sensor for Continuous Monitoring
    Anuar, Hamizah
    Leow, Pei Ling
    2019 IEEE INTERNATIONAL CONFERENCE ON SENSORS AND NANOTECHNOLOGY (SN), 2019, : 61 - 64
  • [32] An IR Sensor Based Smart System to Approximate Core Body Temperature
    Partha Pratim Ray
    Journal of Medical Systems, 2017, 41
  • [34] Skin-Attachable Sensor for Continuous Core Body Temperature Monitoring
    Tanaka, Y.
    Matsunaga, D.
    Tajima, T.
    Seyama, M.
    Kato, Issei
    Nagashima, Kei
    IEEE Sensors Journal, 2024, 24 (23) : 38708 - 38714
  • [35] Core body temperature in obesity
    Heikens, Marc J.
    Gorbach, Alexander M.
    Eden, Henry S.
    Savastano, David M.
    Chen, Kong Y.
    Skarulis, Monica C.
    Yanovski, Jack A.
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2011, 93 (05): : 963 - 967
  • [36] Feasibility, reliability, and validity of the mini-clinical evaluation exercise (mCEX) in a medicine core clerkship
    Kogan, JR
    Bellini, LM
    Shea, JA
    ACADEMIC MEDICINE, 2003, 78 (10) : S33 - S35
  • [37] The Validity of Temperature-Sensitive Ingestible Capsules for Measuring Core Body Temperature in Laboratory Protocols
    Darwent, David
    Zhou, Xuan
    van den Heuvel, Cameron
    Sargent, Charli
    Roach, Greg D.
    CHRONOBIOLOGY INTERNATIONAL, 2011, 28 (08) : 719 - 726
  • [38] Effect of clothing constructions on core temperature during exercise and recovery at an ambient temperature
    Hee Sam Kim
    Han Do Ghim
    Young Hee Lee
    Fibers and Polymers, 2008, 9 : 232 - 239
  • [39] Effect of clothing constructions on core temperature during exercise and recovery at an ambient temperature
    Kim, Hee Sam
    Do Ghim, Han
    Lee, Young Hee
    FIBERS AND POLYMERS, 2008, 9 (02) : 232 - 239
  • [40] Core Body Temperature Decreases during Weight Loss in Obesity
    Neff, Lisa M.
    Zeiss, Dinah M.
    Hoffmann, Mindy
    Lowry, Katherine
    Edwards, Monica
    Landsberg, Lewis
    ENDOCRINE REVIEWS, 2014, 35 (03)