The calibration of targeting errors for an ultrasound-guided high-intensity focused ultrasound system

被引:0
|
作者
Li, Ke [1 ,2 ]
Bai, Jingfeng [1 ,2 ]
Chen, Yazhu [1 ,2 ]
Ji, Xiang [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Biomed Instrument Inst, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Med X Engn Res Ctr, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Targeting accuracy; Ultrasound-guided high-intensity focused ultrasound (USgHIFU); Calibration; Phasedarray; ACCURACY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate targeting is one indispensable feature of image-guided high-intensity focused ultrasound (HIFU) systems for treatment safety and efficacy. In our previously developed ultrasound-guided phased-array HIFU system, a rotatable imaging probe was mounted into the central hole of applicator for targeting and monitoring. Two-dimensional image sequence of different imaging planes can be obtained by rotation of the probe. The misalignment between the spots predetermined in the image and the spots sonicated in the tissue can result in the ablation of normal tissue outside the targeting volume, and thus targeting error is unavoidable. An acrylic plate internally placing two flat-head bolts was constructed to measure and calibrate the targeting error. The imaging planes were switched from -90 degrees to 90 degrees with a 30 degrees step, and the targeting errors were measured 12 times for each of these planes before and after calibration. The targeting errors in other imaging planes could be estimated by linear interpolation using the measured errors in the nearest two imaging planes. The coordinates of the spots to be sonicated were corrected in consideration of the targeting errors in the selected imaging plane. After calibration, the mean targeting errors were reduced to 0.30 similar to 0.68 mm from 0.86 similar to 1.74 mm. Besides, in the ex vivo experiment the needle-thermocouple tip was used as the target which could be identified in the image. The temperature rise measured by the thermocouple during sonication was in accordance with the theoretical result. In conclusion, the calibration of targeting errors is effective for our system, and the targeting accuracy is also capable to ensure safe sonication.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [41] Ultrasound-Guided High-Intensity Focused Ultrasound (USgHIFU) Ablation in Pancreatic Metastasis from Renal Cell Carcinoma
    Gianluigi Orgera
    Miltiadis Krokidis
    Lorenzo Monfardini
    Paolo Arnone
    Guido Bonomo
    Paolo Della Vigna
    Giuseppe Curigliano
    Franco Orsi
    CardioVascular and Interventional Radiology, 2012, 35 : 1258 - 1261
  • [42] Third-Trimester Spontaneous Uterine Rupture After Ultrasound-Guided High-Intensity Focused Ultrasound Therapy
    Yang, Juanjuan
    Zhang, Jiayi
    Shi, Yun
    Shui, Jie
    Qian, Hongying
    MATERNAL-FETAL MEDICINE, 2024, 6 (01) : 57 - 59
  • [43] Third-Trimester Spontaneous Uterine Rupture After Ultrasound-Guided High-Intensity Focused Ultrasound Therapy
    Yang Juanjuan
    Zhang Jiayi
    Shi Yun
    Shui Jie
    Qian Hongying
    母胎医学杂志(英文), 2024, 06 (01)
  • [44] Association between adipose tissue thickness and fibroid shrinkage using ultrasound-guided high-intensity focused ultrasound
    Peiser, G. C. W.
    Jacobs, K.
    Spence, R. T.
    Setzen, R.
    SAJOG-SOUTH AFRICAN JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2020, 26 (03): : 94 - 98
  • [45] Preliminary First in Human Ultrasound-Guided High-Intensity Focused Ultrasound Treatment in Superficial Lower Limb Veins
    Obermayer, Alfred
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (05) : E126 - E127
  • [46] Multidisciplinary management to optimize outcome of ultrasound-guided high-intensity focused ultrasound (HIFU) in patients with uterine fibroids
    Florian Recker
    Marcus Thudium
    Holger Strunk
    Tolga Tonguc
    Sara Dohmen
    Guido Luechters
    Birgit Bette
    Simone Welz
    Babak Salam
    Kai Wilhelm
    Eva K. Egger
    Ullrich Wüllner
    Ulrike Attenberger
    Alexander Mustea
    Rupert Conrad
    Milka Marinova
    Scientific Reports, 11
  • [47] Multidisciplinary management to optimize outcome of ultrasound-guided high-intensity focused ultrasound (HIFU) in patients with uterine fibroids
    Recker, Florian
    Thudium, Marcus
    Strunk, Holger
    Tonguc, Tolga
    Dohmen, Sara
    Luechters, Guido
    Bette, Birgit
    Welz, Simone
    Salam, Babak
    Wilhelm, Kai
    Egger, Eva K.
    Wuellner, Ullrich
    Attenberger, Ulrike
    Mustea, Alexander
    Conrad, Rupert
    Marinova, Milka
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [48] Maternal and fetal cardiometabolic recovery following ultrasound-guided high-intensity focused ultrasound placental vascular occlusion
    Shaw, Caroline J.
    Rivens, Ian
    Civale, John
    Botting, Kimberley J.
    Allison, Beth J.
    Brain, Kirsty L.
    Niu, Y.
    ter Haar, Gail
    Giussani, Dino A.
    Lees, Christoph C.
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2019, 16 (154)
  • [49] Effectiveness and safety of ultrasound-guided high-intensity focused ultrasound ablation for the treatment of colorectal cancer liver metastases
    Yang, Tong
    Chen, Qian
    Kuang, Lanqiong
    Fu, Zhongxiang
    Wang, Yiran
    Chen, Yu
    Yang, Lixia
    Xu, Yonghua
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2022, 39 (01) : 829 - 834
  • [50] A comparison of the cost-utility of ultrasound-guided high-intensity focused ultrasound and hysterectomy for adenomyosis: a retrospective study
    Liu, X. F.
    Huang, L. F.
    Zhang, C.
    Huang, G. H.
    Yan, L. M.
    He, J.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 40 - 45