The calibration of targeting errors for an ultrasound-guided high-intensity focused ultrasound system

被引:0
|
作者
Li, Ke [1 ,2 ]
Bai, Jingfeng [1 ,2 ]
Chen, Yazhu [1 ,2 ]
Ji, Xiang [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Biomed Instrument Inst, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Med X Engn Res Ctr, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Targeting accuracy; Ultrasound-guided high-intensity focused ultrasound (USgHIFU); Calibration; Phasedarray; ACCURACY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate targeting is one indispensable feature of image-guided high-intensity focused ultrasound (HIFU) systems for treatment safety and efficacy. In our previously developed ultrasound-guided phased-array HIFU system, a rotatable imaging probe was mounted into the central hole of applicator for targeting and monitoring. Two-dimensional image sequence of different imaging planes can be obtained by rotation of the probe. The misalignment between the spots predetermined in the image and the spots sonicated in the tissue can result in the ablation of normal tissue outside the targeting volume, and thus targeting error is unavoidable. An acrylic plate internally placing two flat-head bolts was constructed to measure and calibrate the targeting error. The imaging planes were switched from -90 degrees to 90 degrees with a 30 degrees step, and the targeting errors were measured 12 times for each of these planes before and after calibration. The targeting errors in other imaging planes could be estimated by linear interpolation using the measured errors in the nearest two imaging planes. The coordinates of the spots to be sonicated were corrected in consideration of the targeting errors in the selected imaging plane. After calibration, the mean targeting errors were reduced to 0.30 similar to 0.68 mm from 0.86 similar to 1.74 mm. Besides, in the ex vivo experiment the needle-thermocouple tip was used as the target which could be identified in the image. The temperature rise measured by the thermocouple during sonication was in accordance with the theoretical result. In conclusion, the calibration of targeting errors is effective for our system, and the targeting accuracy is also capable to ensure safe sonication.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [31] MRI parameters for predicting the effect of ultrasound-guided high-intensity focused ultrasound in the ablation of uterine fibroids
    Liao, L.
    Xu, Y. H.
    Bai, J.
    Zhan, P.
    Zhou, J.
    Li, M. X.
    Zhang, Y.
    CLINICAL RADIOLOGY, 2023, 78 (01) : 61 - 69
  • [32] Alterations in vaginal microbiota in uterine fibroids patients with ultrasound-guided high-intensity focused ultrasound ablation
    Zhang, Ping-Ping
    He, Xue-Ping
    Tang, Wen
    Chen, Han-Wei
    Han, Yuan-Yuan
    FRONTIERS IN MICROBIOLOGY, 2023, 14
  • [33] The effect of ultrasound-guided high-intensity focused ultrasound treatment for cesarean scar pregnancy on ovarian reserve
    Wang, Wenping
    Jiang, Jing
    Chen, Yan
    Li, Chengzhi
    Zhou, Honggui
    Wang, Zhibiao
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 1409 - 1414
  • [34] Outcome of unintended pregnancy after ultrasound-guided high-intensity focused ultrasound ablation of uterine fibroids
    Qin, Juan
    Chen, Jin-Yun
    Zhao, Wen-Peng
    Hu, Liang
    Chen, Wen-Zhi
    Wang, Zhi-Biao
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2012, 117 (03) : 273 - 277
  • [35] Thermal bowel injury after ultrasound-guided high-intensity focused ultrasound treatment of uterine adenomyosis
    Ko, J. K. Y.
    Seto, M. T. Y.
    Cheung, V. Y. T.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2018, 52 (02) : 282 - 283
  • [36] Ovarian Reserve After Ultrasound-Guided High-Intensity Focused Ultrasound for Uterine Fibroids: Preliminary Experience
    Cheung, Vincent Y. T.
    Lam, Tina P. W.
    Jenkins, Caroline R.
    Cheung, Grace K. I.
    Chan, Selina S. Y.
    Choi, W. K.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2016, 38 (04) : 357 - 361
  • [37] Magnetic resonance image-guided versus ultrasound-guided high-intensity focused ultrasound in the treatment of breast cancer
    Sheng Li
    PeiHong Wu
    ChineseJournalofCancer, 2013, 32 (08) : 441 - 452
  • [38] Magnetic resonance image-guided versus ultrasound-guided high-intensity focused ultrasound in the treatment of breast cancer
    Li, Sheng
    Wu, Pei-Hong
    CHINESE JOURNAL OF CANCER, 2013, 32 (08) : 441 - 452
  • [39] Ultrasound-guided high-intensity Ultrasound Therapy for Fibroids - Pilot Study
    不详
    GYNAKOLOGE, 2018, 51 (11): : 918 - 918
  • [40] Ultrasound-guided high-intensity focused ultrasound for symptomatic uterine fibroids: clinical outcome of two European centers
    Dohmen, Sara
    Recker, Florian
    Ivanova, Yoana
    Strunk, Holger M.
    Tonguc, Tolga
    Ramig, Olga
    Thudium, Marcus
    Stader, Judith M.
    Conrad, Rupert
    Essler, Markus
    Egger, Eva-Katharina
    Mustea, Alexander
    Gortchev, Grigor A.
    Dimitrov, Dobromir
    Marinova, Milka
    EUROPEAN RADIOLOGY, 2024,