The calibration of targeting errors for an ultrasound-guided high-intensity focused ultrasound system

被引:0
|
作者
Li, Ke [1 ,2 ]
Bai, Jingfeng [1 ,2 ]
Chen, Yazhu [1 ,2 ]
Ji, Xiang [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Biomed Instrument Inst, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Med X Engn Res Ctr, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Targeting accuracy; Ultrasound-guided high-intensity focused ultrasound (USgHIFU); Calibration; Phasedarray; ACCURACY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate targeting is one indispensable feature of image-guided high-intensity focused ultrasound (HIFU) systems for treatment safety and efficacy. In our previously developed ultrasound-guided phased-array HIFU system, a rotatable imaging probe was mounted into the central hole of applicator for targeting and monitoring. Two-dimensional image sequence of different imaging planes can be obtained by rotation of the probe. The misalignment between the spots predetermined in the image and the spots sonicated in the tissue can result in the ablation of normal tissue outside the targeting volume, and thus targeting error is unavoidable. An acrylic plate internally placing two flat-head bolts was constructed to measure and calibrate the targeting error. The imaging planes were switched from -90 degrees to 90 degrees with a 30 degrees step, and the targeting errors were measured 12 times for each of these planes before and after calibration. The targeting errors in other imaging planes could be estimated by linear interpolation using the measured errors in the nearest two imaging planes. The coordinates of the spots to be sonicated were corrected in consideration of the targeting errors in the selected imaging plane. After calibration, the mean targeting errors were reduced to 0.30 similar to 0.68 mm from 0.86 similar to 1.74 mm. Besides, in the ex vivo experiment the needle-thermocouple tip was used as the target which could be identified in the image. The temperature rise measured by the thermocouple during sonication was in accordance with the theoretical result. In conclusion, the calibration of targeting errors is effective for our system, and the targeting accuracy is also capable to ensure safe sonication.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [1] THE CALIBRATION OF TARGETING FOR AN ULTRASOUND-GUIDED HIGH-INTENSITY FOCUSED ULTRASOUND SYSTEM
    Li, Ke
    Bai, Jing-feng
    Chen, Ya-zhu
    Ji, Xiang
    PROCEEDINGS OF 2016 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES, AND DEVICE APPLICATIONS (SPAWDA), 2016, : 213 - 216
  • [2] Experimental evaluation of targeting accuracy of an ultrasound-guided phased-array high-intensity focused ultrasound system
    Li, Ke
    Bai, Jingfeng
    Chen, Yazhu
    Ji, Xiang
    APPLIED ACOUSTICS, 2018, 141 : 19 - 25
  • [3] Ultrasound-guided high-intensity focused ultrasound in the treatment of uterine fibroids
    Fan, Hong-Jie
    Zhang, Chao
    Lei, Hong-Tao
    Cun, Jiang-Ping
    Zhao, Wei
    Huang, Jian-Qiang
    Zhai, Yue
    MEDICINE, 2019, 98 (10)
  • [4] Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
    Li, Ke
    Bai, Jingfeng
    Chen, Yazhu
    Ji, Xiang
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (145):
  • [5] Ultrasound-Guided High-Intensity Focused Ultrasound (HIFU) Treatment of Breast Fibroadenoma
    Kovatcheva, Roussanka
    Stoinov, Julian Ivanov
    Abehsera, Marc
    Seror, Bernard
    Guglielmina, Jean-Noel
    ANNALS OF SURGICAL ONCOLOGY, 2013, 20 : 52 - 52
  • [6] Effective ablation therapy of adenomyosis with ultrasound-guided high-intensity focused ultrasound
    Zhang, Xin
    Li, Kequan
    Xie, Bin
    He, Min
    He, Jia
    Zhang, Lian
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2014, 124 (03) : 207 - 211
  • [7] Feasibility and efficacy of ultrasound-guided high-intensity focused ultrasound of breast fibroadenoma
    Liang, Mengdi
    Zhang, Zhizheng
    Zhang, Cai
    Chen, Rui
    Xiao, Yao
    Li, Zi
    Li, Tao
    Liu, Yuelin
    Ling, Lijun
    Xie, Hui
    Chen, Lin
    Liu, Xiaoan
    Wang, Shui
    Xia, Tiansong
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2023, 40 (01)
  • [8] ULTRASOUND-GUIDED HIGH-INTENSITY FOCUSED ULTRASOUND FOR DEVASCULARIZATION OF UTERINE FIBROID: A FEASIBILITY STUDY
    Zhou, Yun
    Ji, Xiang
    Niu, Jianmei
    Sun, Taotao
    Qian, Zhaoxia
    Li, Yuhong
    Yuan, Jiangjing
    Fan, Qiong
    Huang, Qianwen
    Bai, Jingfeng
    Wang, Yudong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (09): : 2622 - 2635
  • [9] The impact of ultrasound-guided high-intensity focused ultrasound for uterine fibroids on ovarian reserve
    Qu, Kaiyin
    Mao, Shihua
    Li, Jaeseong
    Wang, Jian
    Ouyang, Guang
    Wang, Zhi
    Wang, Zhibiao
    Xiong, Yu
    Zhang, Lian
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 399 - 403
  • [10] Ultrasound-guided high-intensity focused ultrasound ablation for treating uterine arteriovenous malformation
    Yan, X.
    Zhao, C.
    Tian, C.
    Wen, S.
    He, X.
    Zhou, Y.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 93 - 96