The optimal activation of plastic aligner for canine distal movement: a three-dimensional finite element analysis

被引:4
|
作者
Li, Ruohan [1 ]
She, Wenting [1 ]
Luo, Yu [1 ]
Wang, Juan [1 ]
Peng, Youjian [1 ]
Ye, Qingsong [1 ,2 ]
机构
[1] Wuhan Univ, Renmin Hosp, Wuhan, Hubei, Peoples R China
[2] Massachusetts Gen Hosp, Harvard Sch Dent Med, Boston, MA USA
关键词
Plastic aligner; Activation; Tooth movement; Stress; Strain; ORTHODONTIC TOOTH MOVEMENT; PERIODONTAL-LIGAMENT; CENTRAL INCISOR; INITIAL FORCE; PRESSURE; ROOT;
D O I
10.1007/s10266-021-00663-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to investigate the optimal activation of plastic aligner for the canine distal movement by combining the stress and strain of periodontal ligament. Computer-aided design models of the upper canine, periodontal ligament, alveolar bone, and plastic aligner were constructed. The stresses and strains of periodontal ligament were acquired by fitting plastic aligner on the canine, which will cause the canine distal-direction movement. The activation of plastic aligner was set into 12 groups, including 0.050, 0.100, 0.125, 0.150, 0.175, 0.200, 0.225, 0.250, 0.275, 0.300, 0.350, and 0.400 mm. Assuming the volume-averaged hydrostatic stress (VAHS) ranging from 4.7 to 16 kPa to be the optimal stress, and an average strain no less than 0.3 to be the optimal strain. The optimal activation of plastic aligner was acquired based on the optimal stress and average strain. As the activation increased, the stress and strain of periodontal ligament increased visibly. The degree of activation of plastic aligner was nonlinearly and positively related to VAHS and average strain. According to the fitted curves, the activation corresponding to the optimal stress was 0.07-0.24 mm and the activation was not less than 0.21 mm based on the optimal strain. The optimal activation of plastic aligner for the canine distal movement was 0.21-0.24 mm in this study. The degree of activation affects the force system of orthodontic tooth movement, and it should be taken into consideration to obtain healthy and efficient tooth movement. The activation with 0.21-0.24 mm seems optimal for orthodontic tooth movement in the plastic aligner system in this study.
引用
收藏
页码:305 / 312
页数:8
相关论文
共 50 条
  • [41] Three-dimensional elastic-plastic finite element analysis of biaxially loaded cracked plates
    Kim, Y
    Chung, KH
    Kim, JS
    Kim, YJ
    ADVANCES IN FRACTURE AND FAILURE PREVENTION, PTS 1 AND 2, 2004, 261-263 : 699 - 704
  • [42] Three-dimensional thermo-elastic-plastic finite element analysis with different cutting speeds
    Lin, ZC
    Zhang, YL
    INTERNATIONAL JOURNAL OF COMPUTER APPLICATIONS IN TECHNOLOGY, 2000, 13 (3-5) : 210 - 220
  • [43] Three-dimensional elasto-plastic finite element analysis of a soil-pilebridge interaction
    朱叶艇
    ZHANG Zi-xin
    YUAN Deng-ping
    HUANG Xin
    JournalofChongqingUniversity(EnglishEdition), 2017, 16 (01) : 25 - 37
  • [44] CONSTRUCTION AND VALIDATION OF A THREE-DIMENSIONAL FINITE ELEMENT MODEL OF THE DISTAL RADIOULNAR JOINT
    Sun, Jianwei
    Yan, Bingshan
    Nie, Wenzhong
    Zhi, Zhongzheng
    Gui, Keke
    Wang, Mingxin
    Yin, Wangping
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2016, 16 (02)
  • [45] Three-dimensional finite element analysis of the uprighting movement of mandibular mesially inclined second molars
    Zheng, Bowen
    Ran, Junyi
    He, Jia
    Al-Yafrusee, Enas Senan Ali Mohammed
    Zhao, Yang
    Liu, Yi
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2024, 165 (03) : 314 - 320
  • [46] Three-dimensional stochastic finite element method for elasto-plastic bodies
    Anders, M
    Hori, M
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2001, 51 (04) : 449 - 478
  • [47] Effects of periodontal bone loss on the natural frequency of the human canine: a three-dimensional finite element analysis
    Shen, Li-Kuo
    Huang, How-Ming
    Yu, Jun-Jea
    Lee, Sheng-Yang
    Lee, Chih-Ming
    Hsieh, Sung-Chih
    JOURNAL OF DENTAL SCIENCES, 2009, 4 (02) : 81 - 86
  • [48] Contact analysis of a posterior cervical spine plate using a three-dimensional canine finite element model
    Villarraga, ML
    Anderson, RC
    Hart, RT
    Dinh, DH
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (02): : 206 - 214
  • [49] Pseudo three-dimensional finite element
    Triche, MH
    Richardson, JA
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (07): : 832 - 835
  • [50] Analysis of three-dimensional effect of tunnel face stability on sandy ground with a clay layer by the three-dimensional rigid plastic finite element method
    Konishi, S
    Tamura, T
    MODERN TUNNELING SCIENCE AND TECHNOLOGY, VOLS I AND II, 2001, : 121 - 126